Order Entry
Czech Republic
ContactUsLinkComponent
179 results for "Solid Phase Extraction"

179 Results for: "Solid Phase Extraction"

Sort By
Extraction unit and drying attachment, LiChrolut®

Extraction unit and drying attachment, LiChrolut®

Supplier: Merck

All the individual steps associated with solid phase extraction can be carried out using the LiChrolut® extraction unit. This transparent and vacuum-suitable unit, made of glass, can be used to prepare up to 12 samples simultaneously.

Expand 3 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Simazine

Supplier: Merck

Simazine CRM may also be used as given below: Development and validation of an ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME) method for sample extraction followed by gas chromatography-mass spectrometry based determination of endocrine-disrupting herbicides in the river and seawater samples. Determination of triazine pesticide residues in samples of apples pears carrots potatoes tomatoes avocado cucumber spinach bananas and oranges by modified QuEChERS and solid-phase extraction (SPE) procedures followed by liquid chromatography-photodiode array (LC-DAD) analysis. Multi-residue analysis of 67 pesticides in olive oil olives and avocado samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) to evaluate various clean-up sorbents. Quantitation of 20 pesticides in eel and shrimp samples by a scheduled multiple reaction monitoring (sMRM) method and QuEChERS with EDTA for sample extraction and purification. Analysis of 35 micropollutants including pesticides in water samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after their solid-phase extraction. Simultaneous quantification of 58 pharmaceuticals and personal care products (PPCPs) and pesticides in water samples by solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) combined with liquid chromatography-tandem mass spectrometry (LCMS/MS).

Expand 1 Items
Loading...
Hazardous Waste Filtration System

Hazardous Waste Filtration System

Supplier: MILLIPORE

If your waste samples contain non-volatile or semi-volatile substances or metals, use this hazardous waste filtration system for saparation, extratction, and filtration. Developed in collaboration with the US Environmental Protection Agency (EPA), the system is designed specifically for the US EPA Extraction Procedure (EP) Toxicity Test and Toxicity Characteristic Leaching Procedure (TCLP). The device separates solid and liquid phases of waste samples for analysis.

Expand 2 Items
Loading...
Accessories for empty solid phase extraction columns CHROMABOND®

Accessories for empty solid phase extraction columns CHROMABOND®

Supplier: MACHEREY-NAGEL

CHROMABOND®, Adapters (PVDF) for glass columns (3 and 6 ml)

Expand 16 Items
Loading...

Accessories for solid phase extraction cartridges, Bond Elut™ SPEC

Supplier: VARIAN

Bond Elut™, Environmental disk manifold

Expand 3 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Monolinuron

Supplier: Merck

Monolinuron CRM may also be used as given below: Determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Extraction of 13 pesticides from four groundwater and three river water samples using silica-based MSU-1 mesoporous solid as a sorbent for their solid-phase extraction (SPE) followed by ultra-performance liquid chromatography-triple quadrupole-mass spectrometric (UHPLC- QqQ-MS/MS) determination. Development and validation of a UHPLC-diode array detection (DAD) method for simultaneous determination of urea and tebuthiuron herbicides in four fresh vegetable samples. Multi-residue analysis of 50 herbicides in 51 grain samples of soybean corn and wheat by ultra-performance liquid chromatography-electrospray ionisation-mass spectrometry (UPLC-ESI-MS). Extraction of 109 pesticide residues from different chemical classes from 345 tomato samples by modified QuEChERS method and their determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simultaneous analysis of 238 pesticides and 78 veterinary drugs in 80 bovine milk samples using ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).

Expand 1 Items
Loading...

CHROMABOND® WAX SPE Columns

Supplier: MACHEREY-NAGEL

State-of-the-art spherical polymer for highest demands in solid phase extraction. PS/DVB copolymer with secondary and tertiary ammonium modification for mixed-mode SPE with weak anion exchange and reversed-phase properties (WAX).

Expand 2 Items
Loading...
Solid phase extraction cartridges, HyperSep™ SAX

Solid phase extraction cartridges, HyperSep™ SAX

Supplier: Thermo Fisher Scientific

Strong anion exchange sorbent for extraction of weak acids.

Expand 9 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CN-U

Supplier: VARIAN

Bond Elut CN-U is ideally suited for the extraction of polar compounds from a nonpolar matrix, such as hexane or oils. It is suitable for very polar analytes that may be irreversibly retained on SI or Diol (2OH) SPE phases.

Expand 4 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ C18 EWP

Supplier: VARIAN

Bond Elut™ EWP is based upon standard particle size silica but with 500 Å pores to allow more efficient extraction of large molecules (>15000 MW), which are typically excluded from standard porosity silica phases.

Expand 5 Items
Loading...
Empty solid phase extraction cartridges, Bond Elut™

Empty solid phase extraction cartridges, Bond Elut™

Supplier: VARIAN

Bond Elut empty SPE cartridges are made with high purity polypropylene for cleaner extracts.

Expand 6 Items
Loading...
Solid phase extraction cartridges, LiChrolut®

Solid phase extraction cartridges, LiChrolut®

Supplier: Merck

LiChrolut® solid phase extraction (SPE) cartridges and accessories are manufactured to the highest standards. All SPE cartridges listed below are polypropylene unless otherwise stated. They are compatible with all automated SPE instruments and robots. Three important criteria are carefully controlled.

Expand 7 Items
Loading...
Solid phase extraction cartridges, HyperSep™ SCX

Solid phase extraction cartridges, HyperSep™ SCX

Supplier: Thermo Fisher Scientific

A strong cation exchange sorbent for extraction of charged basic compounds.

Expand 10 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Tebutam

Supplier: Merck

Tebutam CRM may also be used as given below:
Optimisation of sample extraction based on QuEChERS and dispersive-solid-phase extraction (d-SPE) clean-up for the multi-residue analysis of 120 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls by liquid and gas chromatography coupled with tandem mass spectrometry (MS/MS)
Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)
Determination of 90 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls in honey samples by using QuEChERS combined with dispersive solid-phase extraction (SPME) for sample pre-treatment and liquid chromatography-triple-quadrupole tandem mass spectrometry and gas chromatography-ion-trap tandem mass spectrometry for quantitation
Screening and quantification of 569 pesticides in honeysuckle samples by a combination of ultrahigh-performance liquid chromatography (UHPLC) and quadrupole-Orbitrap high-resolution mass spectrometry
Simultaneous determination of 134 pesticide residues in tea samples using d-SPE extraction with a multi-functional filter (MFF) followed by ultra-high performance liquid chromatography (UPLC) and quadrupole time-of-flight mass spectrometry (TOF-MS).

Expand 1 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ C18 OH

Supplier: VARIAN

Bond Elut™ C18 OH is a non-end capped version of the octadecyl bonded phases that enables the silanols on the silica surface to be more active. This low-load C18 has well-controlled silanol activity that permits the fractionation of metabolites and enhances retention of basic compounds compared to an endcapped C18. The pore size makes it a good choice for peptide extraction.

Expand 4 Items
Loading...
Solid phase extraction cartridges, HyperSep™ Diol

Solid phase extraction cartridges, HyperSep™ Diol

Supplier: Thermo Fisher Scientific

A short alkyl chains with polar functional groups are ideal for the isolation of polar compounds.

Expand 9 Items
Loading...
Solid phase extraction cartridges, HyperSep™ C8

Solid phase extraction cartridges, HyperSep™ C8

Supplier: Thermo Fisher Scientific

HyperSep™ C8 cartridges, less retentive alternative to C18 for polar and nonpolar compounds.

Expand 8 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ SAX

Supplier: VARIAN

Bond Elut™ SAX is a strong anion exchange sorbent ideally suited for the extraction of compounds such as carboxylic acids, which may not retain effectively on weak anion exchange sorbents. The sorbent is supplied in the chloride counter ion form. You can modify the selectivity of the phase by replacing the chloride ion with other anions, such as acetate and hydroxide.

Expand 29 Items
Loading...

Solid phase extraction cartridges, HyperSep™ Aminopropyl

Supplier: Thermo Fisher Scientific

A polar sorbent for both polar and anion exchange interactions.

Expand 9 Items
Loading...
Solid phase extraction cartridges, HyperSep™ C18

Solid phase extraction cartridges, HyperSep™ C18

Supplier: Thermo Fisher Scientific

These columns feature a highly retentive alkyl-bonded phase for non polar to moderately polar compounds.

Expand 12 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PCB

Supplier: VARIAN

Bond Elut™ PCB is a specially designed sorbent which allows for the facile extraction of polychlorinated biphenyl (PCB) compounds from a variety of matrices. Desired analytes can be loaded and eluted using a simple, single solvent method prior to analysis by GC/ECD.

Expand 1 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ C2

Solid phase extraction cartridges, Bond Elut™ C2

Supplier: VARIAN

Bond Elut™ C2 is a fairly non-polar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions.

Expand 10 Items
Loading...
Empty solid phase extraction cartridges with two frits, Bond Elut™

Empty solid phase extraction cartridges with two frits, Bond Elut™

Supplier: VARIAN

Clean PP reservoirs contain two PP frits pre-inserted, an ideal configuration for simple filtration.

Expand 7 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Alumina

Supplier: VARIAN

Alumina, like silica, is an extremely polar sorbent. The alumina surface tends to be slightly more stable under high pH conditions than unfunctionalised silica. The small particle size of the Bond Elut™ Alumina range ensures high extraction efficiency even when small bed masses are used.

Expand 18 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ ENV

Supplier: VARIAN

Bond Elut™ ENV, a PS/DVB polymer, is designed for the extraction of polar organic residues. It contains 125 μm spherical particles with a high degree of cross linking, advantageous for high volume, fast flow-through applications.

Expand 8 Items
Loading...

Solid phase extraction cartridges, EnvirElut™

Supplier: VARIAN

EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.

Expand 6 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ AccuCAT

Solid phase extraction cartridges, Bond Elut™ AccuCAT

Supplier: VARIAN

Bond Elut AccuCAT cartridges are mixed bed SPE cartridges consisting of a strong cation exchange (SCX) and a strong anion exchange (SAX) sorbent packed into one bed. AccuCAT is effective for the extraction of acidic, basic and neutral analytes from urine and other biological samples. AccuCAT is particularly effective for catecholamine extraction from bio fluids.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CN-E

Supplier: VARIAN

A medium polarity sorbent with many uses, Bond Elut™ CN-E is ideal for applications in which extremely non-polar compounds would be irreversibly retained on high carbon load sorbents such as C₈ and C₁₈. This endcapped version of the cyano sorbent is best utilised when extracting analytes from an aqueous matrix.

Expand 4 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Mycotoxin

Supplier: VARIAN

Bond Elut™ Mycotoxin is a novel sorbent which cleans up food extracts for improved trichothecene and zearalenone analysis. Results are comparable or superior to competing methods, including immunoaffinity columns (IaC) and charcoal/alumina columns. The sorbent is a proprietary silica-based ion exchange material.

Expand 1 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Tebufenpyrad

Supplier: Merck

Profenofos CRM may also be used as given below: Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. Gas chromatography-tandem mass spectrometry (GC-MS/MS) based analysis of 213 pesticide residues in soybean after their extraction by QuEChERS procedure. Detection of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Multi-residue analysis of 160 multiclass pesticides using ethyl acetate (EtAC)/n. hexane mixture for extraction from chamomile thyme and marjoram samples and their analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). Simultaneous determination of 34 pesticides in various environmental water samples by dispersive liquid-liquid microextraction (DLLME) technique in combination with gas chromatography-mass spectrometry(GC-MS/MS). Quantitation of 40 multi-class insecticides and fungicides in 81 apple samples by using gas- and liquid- chromatography-mass following a QuEChERS-based extraction.

Expand 1 Items
Loading...
Sort By
Recommended for You