373 výsledků pro: "Mass Spectrometry"
Kyselina mravenčí ∼98% (by titrimetric analysis) for mass spectrometry, Fluka™
Supplier: Honeywell Chemicals
Kyselina mravenčí ∼98% (by titrimetric analysis) for mass spectrometry, Fluka™
Expand 3 Items
Pierce™ Digestion Indicator for Mass Spectrometry, Thermo Scientific
Supplier: Thermo Fisher Scientific
The Digestion Indicator for Mass Spectrometry is a non-mammalian recombinant protein (26kDa) with five signature peptides for use in determining the digestion efficiency and reproducibility across multiple samples.
Expand 1 Items
Mass spectrometry controls, peptide retention time calibration mixture, Pierce™
Supplier: Thermo Fisher Scientific
The Pierce mixture enables reversed phase liquid chromatography (LC) and mass spectrometry (LC-MS) users to optimise and confirm correct operation of their equipment.
Expand 2 Items
Pierce™ Silver Stain for Mass Spectrometry
Supplier: Thermo Fisher Scientific
Pierce silver stain for mass spectrometry is a complete kit for rapid and ultra-sensitive silver staining of proteins in polyacrylamide gels and efficient destaining of excised gel pieces for mass spectrometry analysis. This kit enables both first-time and experienced users to achieve consistent and reliable staining using high, low, and gradient-percentage gels in 1D and 2D formats. The optimised staining method ensures extremely sensitive staining while minimizsing covalent crosslinking of protein to the gel matrix, which can inhibit protein recovery. The destaining reagents facilitate complete removal of silver from stained protein bands and maximum protein recovery for subsequent mass spectrometry analysis.
Expand 1 Items
Peptide and protein MALDI-MS calibration kit, ProteoMass™, Supelco®
Supplier: Merck
This kit features a convenient selection of pre-qualified standard peptides, proteins, matrices, and solvents for calibrating and testing matrix assisted laser desorption ionisation (MALDI) mass spectrometers.
Expand 1 Items
Replacement parts for mass spectrometry
Supplier: Agilent
Reducer, 1/8 - 1/16”
Expand 29 Items
Acetonitrile : water : trifluoroacetic acid (50 : 47.5 : 2.5) %, LabReady™, Solvent Blend for mass spectrometry, Riedel-de Haën™
Supplier: Honeywell Chemicals
LabReady™ Solvent Blends
Expand 1 Items
Organic reference standard, Zearalenone-¹³C₁₈ solution, analytical standard, Supelco®
Supplier: Merck
Zearalenone-¹³C₁₈ may be used as an analytical standard for the determination of zearalenone in animal feed by liquid chromatography combined with tandem mass spectrometry (LC-MS/MS).
Expand 1 Items
Pesticide reference standards, Pyridaphenthion, PESTANAL®, analytical standards, Supelco®
Supplier: Merck
Pyridaphenthion may be used as a reference standard for the quantification of pyridaphenthion in biological samples using liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry.
Expand 1 Items
Recombinant SOLu-trypsin (from P. pastoris)
Supplier: Merck
SOLu-Trypsin is an advanced proteomics grade enzyme that is solution stable for mass spectrometry. Recombinant, expressed in Pichia pastoris.
Expand 2 Items
MALDI validation set polystyrene Mp ~700 - 70000, certified reference material, Supelco®
Supplier: Merck
MALDI Standards are suitable for the validation and comparison of MALDI-ToF instruments. Certificates provide MALDI spectra including Mw, Mn and Mp values of select narrow polymers, which differ in molar mass.
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Tebufenpyrad
Supplier: Merck
Profenofos CRM may also be used as given below: Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. Gas chromatography-tandem mass spectrometry (GC-MS/MS) based analysis of 213 pesticide residues in soybean after their extraction by QuEChERS procedure. Detection of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Multi-residue analysis of 160 multiclass pesticides using ethyl acetate (EtAC)/n. hexane mixture for extraction from chamomile thyme and marjoram samples and their analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). Simultaneous determination of 34 pesticides in various environmental water samples by dispersive liquid-liquid microextraction (DLLME) technique in combination with gas chromatography-mass spectrometry(GC-MS/MS). Quantitation of 40 multi-class insecticides and fungicides in 81 apple samples by using gas- and liquid- chromatography-mass following a QuEChERS-based extraction.
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Tebutam
Supplier: Merck
Tebutam CRM may also be used as given below:
Optimisation of sample extraction based on QuEChERS and dispersive-solid-phase extraction (d-SPE) clean-up for the multi-residue analysis of 120 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls by liquid and gas chromatography coupled with tandem mass spectrometry (MS/MS)
Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)
Determination of 90 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls in honey samples by using QuEChERS combined with dispersive solid-phase extraction (SPME) for sample pre-treatment and liquid chromatography-triple-quadrupole tandem mass spectrometry and gas chromatography-ion-trap tandem mass spectrometry for quantitation
Screening and quantification of 569 pesticides in honeysuckle samples by a combination of ultrahigh-performance liquid chromatography (UHPLC) and quadrupole-Orbitrap high-resolution mass spectrometry
Simultaneous determination of 134 pesticide residues in tea samples using d-SPE extraction with a multi-functional filter (MFF) followed by ultra-high performance liquid chromatography (UPLC) and quadrupole time-of-flight mass spectrometry (TOF-MS).
Expand 1 Items
Pesticide reference standard, Ronidazole-d3, VETRANAL(TM), analytical standard, Supelco®
Supplier: Merck
Ronidazole-d₃ may be used internal standard in the determination of avermectins, benzimidazoles and nitroimidazoles residues in bovine muscle tissue using ultra-high performance liquid chromatography coupled with mass spectrometry (UHPLC/MS-MS).
Expand 1 Items
Pesticide reference standard, Promecarb, PESTANAL®, analytical standard, Supelco®
Supplier: Merck
Promecarb may be used as a reference standard for the determination of promecarb in water by solid-phase extraction and liquid chromatography coupled with ionspray mass spectrometry.
Expand 1 Items
Washing solution, Protein-OUT™
Supplier: G-Biosciences
Protein-OUT™ is a washing solution that cleans plastic and glassware used in the proteolytic digestion and peptide isolation for mass spectrometry analysis. The rinsing of plastic and glassware with Protein-OUT™ will remove interfering chemicals and peptides that can leach from the tube walls and interfere or suppress the mass spectrometry signal. In addition, rinsing with Protein-OUT™ removes inadvertent contamination with dust and keratin.
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Monolinuron
Supplier: Merck
Monolinuron CRM may also be used as given below: Determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Extraction of 13 pesticides from four groundwater and three river water samples using silica-based MSU-1 mesoporous solid as a sorbent for their solid-phase extraction (SPE) followed by ultra-performance liquid chromatography-triple quadrupole-mass spectrometric (UHPLC- QqQ-MS/MS) determination. Development and validation of a UHPLC-diode array detection (DAD) method for simultaneous determination of urea and tebuthiuron herbicides in four fresh vegetable samples. Multi-residue analysis of 50 herbicides in 51 grain samples of soybean corn and wheat by ultra-performance liquid chromatography-electrospray ionisation-mass spectrometry (UPLC-ESI-MS). Extraction of 109 pesticide residues from different chemical classes from 345 tomato samples by modified QuEChERS method and their determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simultaneous analysis of 238 pesticides and 78 veterinary drugs in 80 bovine milk samples using ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).
Expand 1 Items
Organic reference standard, Bisphenol E, analytical standard, Supelco®
Supplier: Merck
Bisphenol E may be used as a reference standard in the determination of bisphenol E in beverages using on-line solid-phase extraction with fast liquid chromatography coupled with tandem mass spectrometry (on-line SPE fast LC-MS/MS).
Expand 1 Items
Organic reference standard, Melamine-13C3, analytical standard, VETRANAL™, Supelco®
Supplier: Merck
Melamine-¹³C₃ may be used as an analytical standard for the determination of melamine in milk powder samples by liquid chromatography-electrospray ionisation-isotope dilution mass spectrometry (LC-ESI-IDMS).
Expand 1 Items
Organic reference standard, Leucocrystal Violet-d6, analytical standard, Supelco®
Supplier: Merck
Leucocrystal violet-d₆ might be used as an internal standard in the determination of triphenylmethane dyes in rainbow trout samples using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS).
Expand 1 Items
3-Mercapto-1,2-propanediol ≥97%
Supplier: Spectrum Chemical
Monothioglycerol, also known as 3-Mercaptopropane-1,2-diol and thioglycerol, is often used as a matrix in liquid secondary ion mass spectrometry and fast atom bombardment mass spectrometry.
Expand 1 Items
Pesticide reference standard, Febantel, VETRANAL(TM), analytical standard, Supelco®
Supplier: Merck
Febantel might be utilised as a source of reference standard in the determination of febantel in samples of animal feed and pharmaceutical formulations, using high performance liquid chromatography (HPLC) and high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS-MS).
Expand 1 Items
Organic reference standard, Fenofibric acid, analytical standard, Supelco®
Supplier: Merck
Used as a reference standard in determination of fenofibric acid in samples of human plasma using high performance liquid chromatography (HPLC) and liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS).
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Metrafenone
Supplier: Merck
Metrafenone CRM may also be used in the residue analysis of: 209 pesticides and persistent organic pollutants (POPs) extracted by QuEChERS-based procedure from fresh bovine and chicken liver samples using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). 379 pesticides in human serum samples extracted by QuEChERS method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Metrafenone in nine fresh vegetable samples using matrix solid-phase dispersion (MSPD) and HPLC-UV. Metrafenone in bitter gourd and soil samples using gas chromatography combined with an electron capture detector (GC-ECD).
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Simazine
Supplier: Merck
Simazine CRM may also be used as given below: Development and validation of an ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME) method for sample extraction followed by gas chromatography-mass spectrometry based determination of endocrine-disrupting herbicides in the river and seawater samples. Determination of triazine pesticide residues in samples of apples pears carrots potatoes tomatoes avocado cucumber spinach bananas and oranges by modified QuEChERS and solid-phase extraction (SPE) procedures followed by liquid chromatography-photodiode array (LC-DAD) analysis. Multi-residue analysis of 67 pesticides in olive oil olives and avocado samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) to evaluate various clean-up sorbents. Quantitation of 20 pesticides in eel and shrimp samples by a scheduled multiple reaction monitoring (sMRM) method and QuEChERS with EDTA for sample extraction and purification. Analysis of 35 micropollutants including pesticides in water samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after their solid-phase extraction. Simultaneous quantification of 58 pharmaceuticals and personal care products (PPCPs) and pesticides in water samples by solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) combined with liquid chromatography-tandem mass spectrometry (LCMS/MS).
Expand 1 Items
Pierce™ In-solution Tryptic Digestion and Guanidination Kit
Supplier: Thermo Fisher Scientific
The In-Solution Tryptic Digestion and Guanidination Kit contains proteomics grade trypsin, buffers and reagents to alkylate and digest proteins and then guanidinate the peptide fragments for mass spectrometry.
Expand 1 Items
SYPRO® Ruby Protein Gel Stain
Supplier: LONZA
SYPRO™ Ruby Protein Gel Stain is highly sensitive, simple to use fluorescent stain that can accurately quantitate protein expression levels, and is compatible with standard fluorescent visualization systems and downstream identification techniques such as mass spectrometry.
Expand 2 Items
Isobaric labelling reagent set, iodoTMTsixplex™
Supplier: Thermo Fisher Scientific
The iodoTMTsixplex™ labelling reagents enable concurrent identification and multiplexed quantitation of proteins in different samples using tandem mass spectrometry.
Expand 2 Items
Graphite spin columns, Pierce™
Supplier: Thermo Fisher Scientific
Pierce™ Graphite spin columns improve phosphopeptide analysis by efficiently binding hydrophilic peptides and efficiently removing urea, salts and other contaminants before mass spectrometry analysis.
Expand 1 Items
Organic reference standard, 2,3-Hexanedione, analytical standard, Supelco®
Supplier: Merck
2,3-Hexanedione can be used as an internal standard for the quantitative determination of methylglyoxal present in the tissues of Sprague-Dawley rats using electrospray ionization liquid chromatography coupled with mass spectrometry(ESI/LC/MS).