Zadání objednávky
Czech Republic
Orders LinkContactUsLinkComponent
 

Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216

Dodavatel:   Thermo Orion
Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216
Dodavatel:  Thermo Orion
Certifikáty
Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216

2 Dostupných variant níže

Product Details & Documents

This benchtop meter is ideal for a wide range of applications and advanced pH and dissolved oxygen analysis in the lab. It offers two measuring channels allowing users to measure pH and dissolved oxygen simultaneously or view each channel separately. Can be used with RDO optical or polarographic DO probes.

  • Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
  • Measurement stability indicator and selectable read modes - Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
  • Data log collects and date/time stamps up to 2000 measurement sets with optional sample ID and user ID
  • Calibration log stores ten most recent calibrations
  • Non volatile meter memory ensures your data and settings are protected, even with loss of power
  • Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
  • Flexible power options with universal power adapter or optional AA batteries
  • Three year meter warranty

IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.

Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two.

Perform up to a five point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values and calibration editing option that allows individual points to be fixed without a full recalibration. Calibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options.

Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings.

 : Supplied with electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate.
The kit additionally includes: 8157BNUMD ROSS Ultra Triode refillable epoxy-body pH/ATC electrode, 083005MD Polarographic DO sensor with calibration sleeve, ROSS pH buffer and storage solution kit, DO sensor maintenance kit and BOD adapter, funnel and stirrer.

Specifications for Product Family

Specifikace

  • Catalog No:
  • 665-0273
  • 665-0274
  • Model:
  • A216
  • A216
  • Rozsah - pH:
  • –2,000...+20,000
  • –2,000...+20,000
  • Rozlišení - pH:
  • 0,1/0,01/0,001
  • 0,1/0,01/0,001
  • Přesnost - pH:
  • ±0,002
  • ±0,002
  • Kalibrace - pH:
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Rozsah - mV:
  • ±2000,0
  • ±2000,0
  • Rozlišení - mV:
  • 0,1
  • 0,1
  • Přesnost - mV:
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • DO koncentrace:
  • 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
  • 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
  • Rozpuštěný kyslík - rozlišení:
  • 0,1/0,01 mg/L
  • 0,1/0,01 mg/L
  • Rozpuštěný kyslík - saturace O₂:
  • 0 - 600% (polarographic); 0 - 500% (RDO)
  • 0 - 600% (polarographic); 0 - 500% (RDO)
  • DO přesnost:
  • Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
  • Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
  • DO - kalibrace:
  • Water-saturated air, air saturated water, manual (Winkler) and zero point
  • Water-saturated air, air saturated water, manual (Winkler) and zero point
  • Rozpuštěný kyslík - rozsah barometrického tlaku:
  • Automatic or manual, 450 - 850 mm Hg
  • Automatic or manual, 450 - 850 mm Hg
  • Rozsah rozpuštěného kyslíku:
  • 0,00 - 90,00 mg/L
  • 0,00 - 90,00 mg/L
  • Rozsah teplot:
  • –5,0...+50,0 °C
  • –5,0...+50,0 °C
  • Rozlišení teploty:
  • 0,1 °C
  • 0,1 °C
  • Přesnost teploty:
  • ±0,1 °C
  • ±0,1 °C
  • Kompenzace teploty:
  • Automatic or manual
  • Automatic or manual
  • Rozsah tlaku:
  • 400 - 850 mm Hg
  • 400 - 850 mm Hg
  • Displej:
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Typ baterie:
  • 4 AA (sold separately)
  • 4 AA (sold separately)
  • Životnost baterie:
  • 800 h
  • 800 h
  • Napájení:
  • AC adapter (included) or 4 AA batteries
  • AC adapter (included) or 4 AA batteries
  • Shoda:
  • CE, TUV 3-1, FCC Class A
  • CE, TUV 3-1, FCC Class A
  • Rozsah provozních teplot:
  • 5...45 °C (ambient)
  • 5...45 °C (ambient)
  • Datalog - funkce log:
  • Manual/Automatic with AUTO-READ™
  • Manual/Automatic with AUTO-READ™
  • Kapacita pro ukládání dat:
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • Paměť:
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Jazyky:
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • Hodnota IP:
  • IP 54
  • IP 54
  • Připojení:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • Výstupy:
  • RS232, USB
  • RS232, USB
  • Vstup:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • Alarm:
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • Počet kanálů:
  • 2
  • 2
  • Kalibrace:
  • pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
  • pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
  • Kalibrační body:
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • Š×H×V:
  • 240×180×110 mm
  • 240×180×110 mm
  • Hmotnost:
  • 0,9 kg
  • 0,9 kg

Specifikace

Product Family Options

Informace o produktu

  • Sekvence
    Dostupnost
    Price
  • 665-0273
    Bench pH/DO meter Orion Star A216, instrument alone
    Bench pH/DO meter Orion Star A216, instrument alone
    01
    Přihlásit se pro dostupnost
    Přihlásit se pro dostupnost
    1 * 1 KS
    1 * 1 KS - 48 300,00 Kč
    48 300,00 Kč
    1 * 1 KS
       48 300,00 Kč

    Specifikace:
    More
    Specifications
    Cat. No.
    665-0273
    Model
    A216
    Rozsah - pH
    –2,000...+20,000
    Rozlišení - pH
    0,1/0,01/0,001
    Přesnost - pH
    ±0,002
    Kalibrace - pH
    Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
    Rozsah - mV
    ±2000,0
    Rozlišení - mV
    0,1
    Přesnost - mV
    ±0,2 mV or ±0,05% of reading, whichever is greater
    DO koncentrace
    0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
    Rozpuštěný kyslík - rozlišení
    0,1/0,01 mg/L
    Rozpuštěný kyslík - saturace O₂
    0 - 600% (polarographic); 0 - 500% (RDO)
    DO přesnost
    Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
    DO - kalibrace
    Water-saturated air, air saturated water, manual (Winkler) and zero point
    Rozpuštěný kyslík - rozsah barometrického tlaku
    Automatic or manual, 450 - 850 mm Hg
    Rozsah rozpuštěného kyslíku
    0,00 - 90,00 mg/L
    Rozsah teplot
    –5,0...+50,0 °C
    Rozlišení teploty
    0,1 °C
    Přesnost teploty
    ±0,1 °C
    Kompenzace teploty
    Automatic or manual
    Rozsah tlaku
    400 - 850 mm Hg
    Displej
    Graphic LCD with backlight
    Typ baterie
    4 AA (sold separately)
    Životnost baterie
    800 h
    Napájení
    AC adapter (included) or 4 AA batteries
    Shoda
    CE, TUV 3-1, FCC Class A
    Rozsah provozních teplot
    5...45 °C (ambient)
    Datalog - funkce log
    Manual/Automatic with AUTO-READ™
    Kapacita pro ukládání dat
    2000 with date and time stamp
    Paměť
    Non-volatile memory preserves data log, calibration log and meter settings
    Jazyky
    English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
    Hodnota IP
    IP 54
    Připojení
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Výstupy
    RS232, USB
    Vstup
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Alarm
    High/low limit alarm, calibration due alarm
    Počet kanálů
    2
    Kalibrace
    pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
    Kalibrační body
    1 point relative mV (RmV) mode, 1 point ORP mode
    Š×H×V
    240×180×110 mm
    Hmotnost
    0,9 kg
  • 665-0274
    Bench pH/DO meter Orion Star A216, kit incl. ROSS Ultra Triode pH/ATC probe and polarographic DO probe
    Bench pH/DO meter Orion Star A216, kit incl. ROSS Ultra Triode pH/ATC probe and polarographic DO probe
    02
    Přihlásit se pro dostupnost
    Přihlásit se pro dostupnost
    1 * 1 KS
    1 * 1 KS - 78 600,00 Kč
    78 600,00 Kč
    1 * 1 KS
       78 600,00 Kč

    Specifikace:
    More
    Specifications
    Cat. No.
    665-0274
    Model
    A216
    Rozsah - pH
    –2,000...+20,000
    Rozlišení - pH
    0,1/0,01/0,001
    Přesnost - pH
    ±0,002
    Kalibrace - pH
    Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
    Rozsah - mV
    ±2000,0
    Rozlišení - mV
    0,1
    Přesnost - mV
    ±0,2 mV or ±0,05% of reading, whichever is greater
    DO koncentrace
    0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
    Rozpuštěný kyslík - rozlišení
    0,1/0,01 mg/L
    Rozpuštěný kyslík - saturace O₂
    0 - 600% (polarographic); 0 - 500% (RDO)
    DO přesnost
    Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
    DO - kalibrace
    Water-saturated air, air saturated water, manual (Winkler) and zero point
    Rozpuštěný kyslík - rozsah barometrického tlaku
    Automatic or manual, 450 - 850 mm Hg
    Rozsah rozpuštěného kyslíku
    0,00 - 90,00 mg/L
    Rozsah teplot
    –5,0...+50,0 °C
    Rozlišení teploty
    0,1 °C
    Přesnost teploty
    ±0,1 °C
    Kompenzace teploty
    Automatic or manual
    Rozsah tlaku
    400 - 850 mm Hg
    Displej
    Graphic LCD with backlight
    Typ baterie
    4 AA (sold separately)
    Životnost baterie
    800 h
    Napájení
    AC adapter (included) or 4 AA batteries
    Shoda
    CE, TUV 3-1, FCC Class A
    Rozsah provozních teplot
    5...45 °C (ambient)
    Datalog - funkce log
    Manual/Automatic with AUTO-READ™
    Kapacita pro ukládání dat
    2000 with date and time stamp
    Paměť
    Non-volatile memory preserves data log, calibration log and meter settings
    Jazyky
    English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
    Hodnota IP
    IP 54
    Připojení
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Výstupy
    RS232, USB
    Vstup
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Alarm
    High/low limit alarm, calibration due alarm
    Počet kanálů
    2
    Kalibrace
    pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
    Kalibrační body
    1 point relative mV (RmV) mode, 1 point ORP mode
    Š×H×V
    240×180×110 mm
    Hmotnost
    0,9 kg
Accessories

Informace o produktu

  • Katalogové číslo
    Sekvence
    Určeno pro
    Dostupnost
    Price
  • Benchtop meter-attached electrode stand (electrode holder arm and head), Orion™ Star A series, 360° motion (without weighted base)
    Benchtop meter-attached electrode stand (electrode holder arm and head), Orion™ Star A series, 360° motion (without weighted base)
    ORIOSTARA-BEA
    103
    Orion Star A110 + A210 series, Orion Versa Star benchtop meters
    Přihlásit se pro dostupnost
    1 * 1 KS - 4 890,00 Kč

Informace o produktu

  • Katalogové číslo
    Sekvence
    Dostupnost
    Price
  • Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cable
    Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cable
    662-1140
    01
    Přihlásit se pro dostupnost
    1 * 1 SET - 2 300,00 Kč

Informace o produktu

  • Katalogové číslo
    Sekvence
    Dostupnost
    Price
  • Spare universal power adapter for Thermo Scientific™ Orion™ Star A series benchtop and portable meters and legacy Orion™ Star and Star Plus series meters
    Spare universal power adapter for Thermo Scientific™ Orion™ Star A series benchtop and portable meters and legacy Orion™ Star and Star Plus series meters
    662-1547
    28
    Přihlásit se pro dostupnost
    1 * 1 KS - 2 180,00 Kč

Informace o produktu

  • Katalogové číslo
    Sekvence
    Dostupnost
    Price
  • Orion™ Star™ A Series weighted base for use with meter-attached electrode stand
    Orion™ Star™ A Series weighted base for use with meter-attached electrode stand
    ORIOSTARA-HB
    104
    Přihlásit se pro dostupnost
    1 * 1 KS - 1 690,00 Kč

Informace o produktu

  • Katalogové číslo
    Sekvence
    Dostupnost
    Price
  • RS232 cable, for connecting a meter to a PC or printer
    RS232 cable, for connecting a meter to a PC or printer
    ORIO1010053
    02
    Přihlásit se pro dostupnost
    1 * 1 KS - 1 370,00 Kč

Informace o produktu

  • Katalogové číslo
    Sekvence
    Dostupnost
    Price
  • Cable adapter, for connecting the RS232 port of a meter to a USB port
    Cable adapter, for connecting the RS232 port of a meter to a USB port
    ORIO1010005
    108
    Přihlásit se pro dostupnost
    1 * 1 KS - 3 930,00 Kč