Order Entry
Czech Republic
ContactUsLinkComponent
 

Hledali jste: Indikátory sterilizace

Indikátory sterilizace

Changing appearances in color or pattern, the sterilization indicators visually show if cleaning conditions are passing or procedures have been completed. Eliminating any confusion or possibility instruments will not be sterile, indicators are used routinely in clinical and research environments where contamination elimination is crucial. With the temperature resistance required to endure the purification, the sterilization indicators are available in different forms such as tapes, ampoules, and sticks. Geobacillus stearothermophilus spores demonstrate a high resistance towards steam and vaporized hydrogen peroxide and are therefore used in BIs that monitor these sterilization processes.

Ethylene oxide chemical indicator strips 1251, Comply™

Ethylene oxide chemical indicator strips 1251, Comply™

Supplier: 3M MEDICAL

The 3M™ Comply™ Steam Chemical Indicator 1251 is a paper strip 1,5 cm wide by 20 cm long printed with a chemical indicator ink that turns from red to green when exposed to the steam sterilisation process.

Expand 1 Items
Načítání...
Rapid readout biological indicator for ethylene oxide sterilisation, 1294, Attest™

Rapid readout biological indicator for ethylene oxide sterilisation, 1294, Attest™

Supplier: 3M MEDICAL

Rapid readout biological indicator for EO (ethylene oxide) sterilization.

Expand 1 Items
Načítání...
Super Rapid Readout Steam Challenge Pack 1496VX, 3M™ Attest™

Super Rapid Readout Steam Challenge Pack 1496VX, 3M™ Attest™

Supplier: 3M MEDICAL

Twenty four minute Biological Indicator Challenge Pack for 132°C (270°F) 4 minute and 135°C (275°F) 3 minute Dynamic Air Removal Steam Sterilization. Each pack contains one 3M™ Attest™ Super Rapid Readout Biological Indicator 1492V.

Expand 1 Items
Načítání...

Sterilisation indicators

Supplier: 3M MEDICAL

These chemical integrators are Class 5 integrating indicators used for pack control as a method for monitoring sterilisation process conditions inside each pack. They can also be used inside a process challenge device (PCD) to release processed items, excluding implants (load control), however they do not replace the use of biological indicators.

Expand 1 Items
Načítání...

Spore ampoules

Supplier: CROSSTEX

These spore ampoules are ideal for use in validation and routine monitoring of liquid steam sterilization cycles. Spore ampoules are manufactured using hermetically sealed Type I borosilicate glass containing an exclusively formulated Tryptic
Soy Broth (TSB) modified with pH indicator, and Geobacillus stearothermophilus spores. No activation is required; simply expose Spore Ampoules to sterilization process and incubate.

Expand 7 Items
Načítání...

Labels, indicator, for dry heat and depyrogenation

Supplier: CROSSTEX

CPI-DP1 are intended for use with individual units (e.g. packs, containers) to indicate that the unit has been directly exposed to a high temperature dry heat or depyrogentation process and to distinguish between processed and unprocessed units.

Expand 1 Items
Načítání...
Dual auto-reader for steam and vaporised hydrogen peroxide 490, Attest™

Dual auto-reader for steam and vaporised hydrogen peroxide 490, Attest™

Supplier: 3M MEDICAL

Auto-reader for use with 3M™ Attest™ Rapid Readout Biological Indicators and process challenge packs for steam. Includes ethernet cable for web app connectivity.

Expand 1 Items
Načítání...
Spore discs, steel

Spore discs, steel

Supplier: CROSSTEX

Spore discs are used to monitor the plasma/vaporised hydrogen peroxide sterilisation processes. Place the spore discs either directly into the chamber or positioned in areas of a device which are the most difficult to sterilise or distributed throughout rooms and isolators.

Expand 1 Items
Načítání...

Self contained biological indicators (SCBI)

Supplier: CROSSTEX

Self-contained biological indicators (SCBIs) for monitoring steam sterilisation consist of a durable PC vial with cap, a crushable glass ampoule with Trypticase® soy broth (TSB) modified with pH indicator, and a disc inoculated with Geobacillus stearothermophilus spores.

Expand 2 Items
Načítání...
Vaporised hydrogen peroxide tri-metric chemical indicator, Attest™

Vaporised hydrogen peroxide tri-metric chemical indicator, Attest™

Supplier: 3M MEDICAL

The 3M™ Attest™ Vaporized Hydrogen Peroxide Tri-Metric Chemical Indicator 1348/1348E verifies that the stated values for the three critical parameters of exposure time, temperature, and amount of vaporized hydrogen peroxide have been achieved within a package or containment device (i.e. wrapped trays, rigid containers, sterilization pouches, and other types of packs) and/or at a specific location within the load or empty chamber.

Expand 1 Items
Načítání...
Dry heat indicator tapes

Dry heat indicator tapes

Supplier: KARTELL

Adhesive tape.

Expand 1 Items
Načítání...
Steam indicator tape, Comply™

Steam indicator tape, Comply™

Supplier: 3M MEDICAL

Indicator tapes are Class 1 process indicators used for exposure monitoring. They provide assurance to the operator handling the processed items that the pack has been exposed to the sterilisation process without the need to open the pack or check load control records. Optional tape dispensers are available for easy dispensing of indicator tapes.

Expand 1 Items
Načítání...
Autoklávové pásky

Autoklávové pásky

Supplier: PRECISION DYNAMICS TIMEM

White adhesive crepe tape, for use in standard autoclaves.

Expand 3 Items
Načítání...
Autoclave Sterilisation Tape

Autoclave Sterilisation Tape

Supplier: KARTELL

Adhesive tape.

Expand 1 Items
Načítání...
Bioindicator, Sterikon® plus

Bioindicator, Sterikon® plus

Supplier: Merck

Sterikon® plus bioindicators can be used to test the functionality of autoclaves (15 minutes at 121 °C). They can also be used to check any sort of autoclave load for the success of sterilisation. For example, pharmaceuticals, particularly products in ampoules, canned food and more.

Expand 1 Items
Načítání...
Gamma radiation sterilisation indicator labels

Gamma radiation sterilisation indicator labels

Supplier: CROSSTEX

Self-adhesive, non-toxic, chemical process indicators that change from yellow to red upon exposure to gamma or electron beam radiation. Labels are coated with a UV blocking agent for protection from exposure to UV light. A minimum of 15 kGy irradiation is recommended for sufficient end-point colour development. At greater dosage levels, the radiation indicators exhibit a darker shade of red.

Expand 3 Items
Načítání...
Sterilisation indicators

Sterilisation indicators

Supplier: S▄DPACK MEDICA

Tapes indicators by dry heat sterilisation.

Expand 1 Items
Načítání...
Autoclave test packs, Bowie and Dick type, Comply™

Autoclave test packs, Bowie and Dick type, Comply™

Supplier: 3M MEDICAL

With unique colour chemistry, the 3M™ Comply™ Disposable Bowie and Dick Type Autoclave Test Pack has been designed for single use in porous load sterilizers for daily Bowie and Dick tests.

Expand 1 Items
Načítání...
Gamma/beta ray sterilisation indicators

Gamma/beta ray sterilisation indicators

Supplier: S▄DPACK MEDICA

The discs are available in a variety of blank or printed versions.

Expand 3 Items
Načítání...
Spore strips, Attest™

Spore strips, Attest™

Supplier: 3M MEDICAL

Biological indicators provide the best assurance of sterility by challenging the steriliser with quantifiable, highly resistant spores. After sterilisation, the vial is 'crushed' to join the growth media with the processed spore strip. A colour change to yellow indicates surviving spores and a positive result. Biological indicators are used for load control monitoring which is the process by which a load is monitored and released based on the result of a biological indicator (BI) in a test pack.

Expand 1 Items
Načítání...
Spore suspensions, Sportrol™

Spore suspensions, Sportrol™

Supplier: CROSSTEX

Spore suspensions are pure suspensions of viable spores from specific organisms of known resistance to various sterilisation processes. These biological indicators are used to validate that bacterial spores have been completely destroyed. The indicator is simply processed with the load in the steriliser. No bacterial growth after culturing indicates that the sterilisation process is effective. Growth indicates ineffective sterilisation.

Expand 3 Items
Načítání...
Spore strips, Sportrol™

Spore strips, Sportrol™

Supplier: CROSSTEX

Biological sterilisation indicators are used to perform sterilisation cycle validation. They are created by inoculating spore suspensions of certified population and resistance onto paper strips.

Expand 7 Items
Načítání...
Sterilisation indicators

Sterilisation indicators

Supplier: S▄DPACK MEDICA

The indicator turns a different colour depending on the time and temperature of sterilisation:

Expand 1 Items
Načítání...
Steam sterilisation indicator labels

Steam sterilisation indicator labels

Supplier: CROSSTEX

Self-adhesive, non toxic, chemical process indicators change from blue to pink upon exposure to 10 minutes of saturated steam at 121 °C or 2 minutes at 134 °C. Longer exposure will result in a brighter shade of pink. The blue to pink colour transition is sensitive to time, temperature, and the presence of saturated steam.

Expand 1 Items
Načítání...
Steam sterilisation indicators

Steam sterilisation indicators

Supplier: S▄DPACK MEDICA

Steam sterilisation. The labels change colour from pink to dark brown after sterilisation.

Expand 1 Items
Načítání...
Ethylene oxide sterilisation indicators

Ethylene oxide sterilisation indicators

Supplier: S▄DPACK MEDICA

The discs are available in a variety of blank or printed versions.

Expand 2 Items
Načítání...
Autoclave type test packs, bowie and dick type, Comply™

Autoclave type test packs, bowie and dick type, Comply™

Supplier: 3M MEDICAL

The Bowie and Dick test is carried out daily in an empty chamber after a warm up cycle and is designed to show the adequacy of steam penetration.

Expand 1 Items
Načítání...
Spore discs, Sportrol™

Spore discs, Sportrol™

Supplier: CROSSTEX

Biological sterilisation discs are used to perform sterilisation cycle validation in small areas of a device, where a standard-sized spore strip will not fit, such as within a syringe barrel, inside tubing, or under a cap. Spore discs are created by inoculating spore suspensions of certified population and resistance onto paper discs.

Expand 2 Items
Načítání...
Recommended for You