订单输入
China
Orders LinkContactUsLinkComponent
 

Cell culture chambers, Corning® CellSTACK®

02, 2 chambers, 250 - 380 ml, 1272 cm²
  CORN3269
   Low Manufacturing Impact
Cell culture chambers, Corning® CellSTACK®
  CORN3269
   Low Manufacturing Impact
Cell culture chambers, Corning® CellSTACK®
Cell culture chambers, Corning® CellSTACK®

02, 2 chambers, 250 - 380 ml, 1272 cm²

 
 
   
1 * 5 件
 

PS, sterile. The Corning® CellSTACK® culture chambers are available in five sizes and with three different surface treatments.

  • Two 26 mm diameter filling ports allow direct access to chamber bottom providing greater flexibility for sterile filling and emptying by pouring, pipetting or via tubing in a fully closed system
  • Standard 33 mm threaded caps have 0,2 μm pore non-wettable membranes sealed directly to the caps to allow gas exchange while minimising the risk of contamination
  • Optional 33 mm threaded caps are available with integrally sealed USP Class VI certified C-Flex® tubing to allow direct sterile transfer of media and cells via pumping or gravity feed
  • Polystyrene construction provides excellent optical clarity and mechanical strength

TC treated surface: Uncharged polystyrene has an uncharged, hydrophobic surface to which cell attachment proteins bind poorly. This results in poor and uneven cell attachment and growth. Tissue culture (TC) treated polystyrene has a negatively charged, hydrophilic surface to which cell attachment proteins bind evenly. This provides a good surface for cell attachment and growth.

Corning® CellBIND® surface: The Corning® CellBIND® surface enhances cell attachment under difficult conditions, such as reduced-serum or serum-free medium, resulting in higher cell yields.
More consistent cell attachment resulting in increased cell growth
Adapts cells more quickly to reduced-serum or serum-free conditions
Reduces premature cell detachment from confluent cultures
May eliminate the need for tedious, time-consuming, low stability biological coatings
Requires no refrigeration or special handling and is stable at room temperature

Ultra-Low Attachment surface: The Ultra-Low Attachment surface is a covalently bonded hydrogel surface that is hydrophilic and neutrally charged. It minimises cell attachment, protein absorption and enzyme activation. The surface is non-cytotoxic, biologically inert and non-degradable.
Maintains cells in a suspended, unattached state
Prevents stem cells from attachment-mediated differentiation
Prevents anchorage-dependent cells from dividing
Reduces binding of attachment and serum proteins to the substrate

Chambers are sterilized by gamma radiation and certified nonpyrogenic. Manufactured under GMP conditions and 100% leak-tested prior to shipping.

The Corning® CellBIND® surface enhances cell attachment under difficult conditions, such as reduced-serum or serum-free medium, resulting in higher cell yields.

 : A variety of optional filling caps are available to allow direct aseptic transfer of media and cells via pumping or gravity feed. Several coupling devices are available on these filling caps with or without integrally sealed USP Class VI certified C-Flex® tubing. Optional filling caps with attached filters with hydrophobic membranes provide for gas exchange and faster aseptic venting during liquid transfers. Extra sterile vented or unvented 33 mm replacement caps are also available. Reusable stacking devices fit between CellSTACK® chambers to keep them level and optimise incubator space while providing clearance for gas exchange.
All caps are 33 mm threaded caps.

 
  • 建议工作容积:
    250 - 380 ml
  • 顺序:
    02
  • 生长面积:
    1272 cm²
  • 类型:
    2 chambers
  • Cat. No.:
    CORN3269
  • 环境认证:
    RECs, ISO 14001 - Kennebunk
  • Environmentally Preferable:
    Low Manufacturing Impact
Accessories

 

  •  
    顺序
    说明
     
     
  • CORN3732
    21
    Universal cap, polyethylene, 33 mm, with vented overcap, double-bagged, sterile
       
    1 * 4 件

 

  •  
    顺序
    说明
     
     
  • CORN3969
    19
    Solid cap, polyethylene, 33 mm, sterile
       
    1 * 6 件

 

  •  
    顺序
    说明
     
     
  • CORN3968
    24
    Vent cap, polyethylene, 33 mm, 0,2 µm membrane, sterile
       
    1 * 6 件

 

  •  
    顺序
    说明
     
     
  • CORN3339
    15
    Fill cap with male MPC; Int. Ø: 9,525 mm
       
    1 * 4 件

 

  •  
    顺序
    说明
     
     
  • CORN3334
    13
    Fill cap with male MPC; Int. Ø: 6,35 mm
       
    1 * 4 件

 

  •  
    顺序
    说明
     
     
  • CORN3329
    11
    Fill cap with female MPC coupling; Int. Ø: 9,525 mm
       
    1 * 4 件

 

  •  
    顺序
    说明
     
     
  • CORN3328
    12
    Fill cap with female MPC; Int. Ø: 6,35 mm
       
    1 * 4 件

 

  •  
    顺序
    说明
     
     
  • CORN3324
    20
    Two vented over caps and one solid over cap
       
    1 * 100 件

 

  •  
    顺序
    说明
     
     
  • CORN3333
    14
    Fill cap with male MPC; Int. Ø: 6,35 mm; Tubing length: 69,85 mm
       
    1 * 4 件

 

  •  
    顺序
    说明
     
     
  • CORN3284
    22
    Vent cap with tubing and 37 mm hydrophobic glass laminate 1,0 μm vent filter; Int. Ø: 6,35 mm; Tubing length: 69,85 mm
       
    1 * 4 件

 

  •  
    顺序
    说明
     
     
  • CORN3331
    10
    Corning CellSTACK stacking device, ABS, nonsterile
       
    1 * 5 件

 

  •  
    顺序
    说明
     
     
  • CORN3283
    16
    Fill cap with tubing and barbed fittings; Int. Ø: 9,525 mm; Tubing length: 457,2 mm
       
    1 * 5 件

 

  •  
    顺序
    说明
     
     
  • CORN3282
    18
    Fill cap with tubing, FLL; Int. Ø: 3,175 mm; Tubing length: 457,2 mm
       

 

  •  
    顺序
    说明
     
     
  • CORN3281
    23
    Vent cap with tubing and 50 mm hydrophobic PVDF 0,2 µm vent filter; Int. Ø: 9,525 mm; Tubing length: 69,85 mm
       
    1 * 5 件