Methanol ≥99.9% (by GC), UltimAR® for liquid chromatography, for organic residue analysis, for UV spectrophotometry, Macron Fine Chemicals™
Supplier: MACRON AVANTOR BRAND
Certificates
About this item
CAS Number:67-56-1
:
Formula:CH₃OH
MDL Number:MFCD00004595
:32.04 g/mol
Merck Index:13,05984
Boiling Pt:64,6 °C (1013 hPa)
Melting Pt:–98 °C
Density:0,7918 g/cm³ (20 °C)
Flash Pt:11 °C (closed cup)
Storage Temperature:Ambient
EINECS:200-659-6
UN:1230
ADR:3,II
REACH:01-2119433307-44
:GHS02
:GHS06
:GHS08
Some Products May Appear Restricted
To ensure a smooth and speedy checkout, please log in to your account. Some items may show as restricted simply because you're not logged in.
If you do not have an account, you can register using our registration webform (https://www.avantorsciences.com/us/en/login/register)
If you're still seeing restrictions after logging in, certain products—like chemicals or medical devices—require additional account verification steps to be able to place an order. Some items may additionally require a specific license or customer documentation; additional documentation will be requested for these items prior to shipment.
Specifications
- Environmentally Preferable:Safer Human and Environmental Health
- 环境认证:Chem21 Solvent Selection Guide recommended after discussion
Specifications
Specification Test Results
- For Laboratory,Research,or Manufacturing Use:Passes Test
- Appearance:Passes Test
- ACS - Assay (CH₃OH) (by GC, corrected for water):≥99.9 %
- Carbonyl Compounds - Acetone:≤0.001 %
- Carbonyl Compounds - Acetaldehyde:≤0.001 %
- Carbonyl Compounds - Formaldehyde:≤0.001 %
- Color (APHA):≤5
- Residue after Evaporation:≤0.00010 %
- Solubility in H₂O:Passes Test
- Substances Darkened by H₂SO₄:Passes Test
- Substances Reducing Permanganate:Passes Test
- Titrable Acid (meq/g):≤0.0003
- Titrable Base (meq/g):≤0.0002
- Water (H₂O)(by Karl Fischer titrn):≤0.05 %
- Ultraviolet Absorbance (1.00-cm cell vs. water) - 205 nm:≤1.00
- Ultraviolet Absorbance (1.00-cm cell vs. water) - 210 nm:≤0.80
- Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm:≤0.25
- Ultraviolet Absorbance (1.00-cm cell vs. water) - 230 nm:≤0.12
- Ultraviolet Absorbance (1.00-cm cell vs. water) - 240 nm:≤0.05
- Ultraviolet Absorbance (1.00-cm cell vs. water) - 260 nm:≤0.01
- Ultraviolet Absorbance (1.00-cm cell vs. water) - 400 - 280 nm:≤0.005
- Liquid Chromatography Suitability Absorbance:Passes Test
- HPLC Gradient Elution (No Peak Greater than 25% of Full Scale)(0.005 au):Passes Test
- ECD Sensitive Impurities (as Heptachl or Epoxide) Single Peak (ng/L):≤5
- Sum of the Peaks (ng/L):≤10
- FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L):≤5
- Sum of the Peaks (µg/L):≤10
- Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities:≤1.0 ppb