867 Results for: "Ion+exchange+resins&"
Anion exchange chromatography column, HiScreen™ Q HP
Supplier: GE HEALTHCARE
HiScreen™ Q HP columns are prepacked with Q Sepharose™ High Performance ion exchange chromatography media designed for intermediate and polishing steps in downstream processing.
Expand 1 Items
Affinity chromatography media, IMAC Sepharose™ High Performance
Supplier: GE HEALTHCARE
IMAC Sepharose High Performance media is easily charged by the user with the metalion of choice for Immobilized Metal ion Affinity Chromatography (IMAC) and subsequent purification of polyhistidine tagged proteins.
Expand 1 Items
Solid phase extraction cartridges, Bond Elut™ Plexa PCX
Supplier: VARIAN
Bond Elut™ Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut™ Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removes neutral and acidic interferences from the matrix, concentrates basic analytes and therefore improves sensitivity in the determination of basic compounds.
Expand 1 Items
Cation exchange chromatography column, HiPrep™ IEX SP Sepharose™ XL
Supplier: GE HEALTHCARE
HiPrep™ SP XL 16/10 is a prepacked, ready to use column for ion exchange chromatography.
Expand 1 Items
Immobilised metal ion affinity chromatography (IMAC) media, Ni Sepharose™ excel
Supplier: GE HEALTHCARE
Ni Sepharose™ excel is an IMAC medium pre-charged with nickel ions very strongly bound to a chelating ligand. Samples that usually cause stripping of metal ions can, therefore, be loaded to the medium. Ni Sepharose™ excel is designed primarily for capture and purification of histidine-tagged proteins secreted into cell culture supernatants from eukaryotic cells such as insect cells or CHO cells.
Expand 2 Items
Cation exchange chromatography column, HiScreen™ Capto™ S
Supplier: GE HEALTHCARE
HiScreen Capto S columns are prepacked with Capto S ion exchange chromatography medium, and are part of the process development platform available from Cytiva. The columns are an excellent choice for method optimization and parameter screening.
Expand 1 Items
Cartridges for Milli-Q®
Supplier: MILLIPORE
Filter cartridge, Milli-Q®, Quantum® TIX polishing cartridge (contains Ionex resin for trace levels of ions)
Expand 2 Items
HiPrep Q FF Columns, Cytiva
Supplier: GE HEALTHCARE
HiPrep Q FF is a strong anion exchanger prepacked with Q Sepharose Fast Flow, ready-to-use for fast, preparative separations of proteins and other biomolecules using ion exchange (IEX) chromatography.
Expand 1 Items
HiPrep DEAE FF Columns, Cytiva
Supplier: GE HEALTHCARE
HiPrep DEAE FF 16/10 is a weak anion exchanger prepacked with DEAE Sepharose Fast Flow, ready-to-use for fast, preparative separations of proteins and other biomolecules using ion exchange (IEX) chromatography.
Expand 1 Items
Affinity chromatography media, Ni Sepharose™ High Performance
Supplier: GE HEALTHCARE
Ni Sepharose™ High Performance affinity media for high resolution, high capacity purification of histidine-tagged proteins by immobilised metal ion affinity chromatography (IMAC).
Expand 2 Items
Cation exchange chromatography column, HiScreen™ SP HP
Supplier: GE HEALTHCARE
HiScreen™ SP HP columns are prepacked with SP Sepharose™ High Performance ion exchange chromatography media of 4,7 ml volume and bed height of 10 cm make HiScreen™ columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up.
Expand 1 Items
Disposable PD-10 desalting columns
Supplier: GE HEALTHCARE
PD-10 Desalting Columns contain Sephadex G-25 resin for rapid buffer exchange, desalting, and removal of small contaminants (salts, dyes, radioactive labels) from samples using gravity flow or centrifugation.
Expand 1 Items
Ion-exclusion HPLC columns, Rezex™
Supplier: PHENOMENEX
Rezex™ HPLC ion-exclusion columns achieve reproducible, accurate separations based on multiple modes of interaction.
Expand 2 Items
Water treatment system, Pure Aqua Service
Supplier: BINDER GMBH
This system is used to fully desalinate faucet water for BINDER climate chamber humidification systems. The ion exchanger system consists of a pressure container, a single-use filter cartridge and a pressure container lid.
Expand 1 Items
Ion exchange chromatography column, HiPrep™ Q HP
Supplier: GE HEALTHCARE
HiPrep Q HP is a 20 ml strong anion exchange chromatography column for high resolution small-scale protein purification.
Expand 1 Items
Affinity chromatography columns, HisTrap™ excel
Supplier: GE HEALTHCARE
HisTrap excel columns are prepacked with Ni Sepharose excel affinity resins for capture and purification of histidine-tagged proteins secreted into eukaryotic cell culture supernatants by immobilized metal ion affinity chromatography (IMAC).
Expand 2 Items
Ion exchange columns, ZORBAX® SAX and SCX
Supplier: AGILENT HEWLETT PACKARD
Both strong anion exchange (SAX) and strong cation exchange (SCX) columns are bonded with spherical silica particles for optimum efficiency. SAX is ideal for separation of water-soluble compounds such as aromatic and aliphatic carboxylic acids and sulphonic acids and SCX is ideal for separations of basic, water-soluble compounds and bio-molecules.
Expand 1 Items
Affinity chromatography column, HiPrep IMAC FF
Supplier: GE HEALTHCARE
HiTrap IMAC FF is prepacked with IMAC Sepharose 6 Fast Flow. The resin is charged with the metalion of your choice for Immobilized Metal ion Affinity Chromatography (IMAC) and subsequent purification of polyhistidine tagged proteins.
Expand 1 Items
Ion exchange HPLC columns, monolith, ProSwift™ IEX
Supplier: Thermo Fisher Scientific
High resolution columns used for fast protein analysis.
Expand 1 Items
Affinity chromatography columns, HiTrap™ IMAC HP
Supplier: GE HEALTHCARE
HiTrap IMAC HP is prepacked with IMAC Sepharose High Performance. The resin is charged with the metalion of your choice for Immobilized Metal ion Affinity Chromatography (IMAC) and subsequent high-resolution purification of polyhistidine tagged proteins.
Expand 2 Items
Affinity chromatography columns, HiTrap IMAC FF
Supplier: GE HEALTHCARE
HiTrap IMAC FF is prepacked with IMAC Sepharose 6 Fast Flow. The resin is charged with the metalion of your choice for Immobilized Metal ion Affinity Chromatography (IMAC) and subsequent purification of polyhistidine tagged proteins.
Expand 2 Items
Strong cation exchange HPLC columns, MAbPac™ SCX-10
Supplier: Thermo Fisher Scientific
These columns are ideal for high-resolution, high efficiency analysis of monoclonal antibodies (mAbs) and associated variants. The unique non porous pellicular resin provides the resolving power to separate mAb variants that differ by as little as one charged residue.
Expand 1 Items
Anti-CD73 Rat Monoclonal Antibody (PE (Phycoerythrin)) [clone: eBioTY/11.8 (TY/11.8)]
Supplier: EBIOSCIENCE
5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest. Excitation: 488-561 nm; Emission: 578 nm; Laser: Blue Laser, Green Laser, Yellow-Green Laser Ecto-5-prime-nucleotidase (5-prime-ribonucleotide phosphohydrolase) catalyzes the conversion at neutral pH of purine 5-prime mononucleotides to nucleosides, the preferred substrate being AMP. The enzyme consists of a dimer of 2 identical 70 kD subunits bound externally to the plasma membrane by a glycosyl phosphatidyl inositol linkage. The enzyme is used as a marker of lymphocyte differentiation. Consequently, a deficiency of NT5E occurs in a variety of immunodeficiency diseases. Other forms of 5-prime nucleotidase exist in the cytoplasm and lysosomes and can be distinguished from ecto-NT5 by their substrate affinities, requirement for divalent magnesium ion, activation by ATP, and inhibition by inorganic phosphate. It is not known whether the different enzymes are coded by different genes or result from different posttranslational modifications of a single coding sequence.
Expand 1 Items
AMP (2-Amino-2-methylpropanol), high purity
Supplier: VWR Chemicals
5% water has been added to maintain liquidity at room temperature.
Expand 1 Items
Affinity chromatography media, TALON® Superflow™
Supplier: GE HEALTHCARE
Cobalt-based chromatography medium designed for purification of histidine-tagged recombinant proteins by immobilised metal affinity chromatography (IMAC).
Expand 2 Items
Adenosine 5'-monophosphate disodium salt (AMP disodium salt) hydrate, Ultra Pure Grade for biochemistry
Supplier: VWR Chemicals
AMP Disodium Hexahydrate
Intermediate in energy metabolism.
Expand 1 Items
DNA clean up, Sephadex® G-50 DNA Grade F
Supplier: GE HEALTHCARE
Sephadex G-50 grade F is a size exclusion chromatography resin designed for desalting and buffer exchange, and for purification of DNA and oligonucleotides greater than 20 bases in length using spin columns.
Expand 2 Items
Anti-CD73 Rat Monoclonal Antibody (PE (Phycoerythrin)-Cyanine7) [clone: eBioTY/11.8 (TY/11.8)]
Supplier: EBIOSCIENCE
5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest. Light sensitivity: This tandem dye is sensitive photo-induced oxidation. Please protect this vial and stained samples from light. Fixation: Samples can be stored in IC Fixation Buffer (cat. 00-8222) (100 µL cell sample + 100 µL IC Fixation Buffer) or 1-step Fix/Lyse Solution (cat. 00-5333) for up to 3 days in the dark at 4°C with minimal impact on brightness and FRET efficiency/compensation. Some generalizations regarding fluorophore performance after fixation can be made, but clone specific performance should be determined empirically. Excitation: 488-561 nm; Emission: 775 nm; Laser: Blue Laser, Green Laser, Yellow-Green Laser Ecto-5-prime-nucleotidase (5-prime-ribonucleotide phosphohydrolase) catalyzes the conversion at neutral pH of purine 5-prime mononucleotides to nucleosides, the preferred substrate being AMP. The enzyme consists of a dimer of 2 identical 70 kD subunits bound externally to the plasma membrane by a glycosyl phosphatidyl inositol linkage. The enzyme is used as a marker of lymphocyte differentiation. Consequently, a deficiency of NT5E occurs in a variety of immunodeficiency diseases. Other forms of 5-prime nucleotidase exist in the cytoplasm and lysosomes and can be distinguished from ecto-NT5 by their substrate affinities, requirement for divalent magnesium ion, activation by ATP, and inhibition by inorganic phosphate. It is not known whether the different enzymes are coded by different genes or result from different posttranslational modifications of a single coding sequence.
Expand 1 Items
Affinity chromatography media, Ni Sepharose™ 6 Fast Flow
Supplier: GE HEALTHCARE
Ni Sepharose 6 Fast Flow is a BioProcess medium that combines the advantages of Ni₂₊ for purification of histidine tagged proteins, with the well industrially established properties of the Sepharose Fast Flow platform.
Expand 4 Items
Cation exchange membranes 125x125 mm
Supplier: VWR Chemicals
Cation exchange membranes 125x125 mm