509 Results for: "GE HEALTHCARE"
illustra™ TempliPhi™100/500 Amplification Kits
Supplier: GE HEALTHCARE
TempliPhi™ Kits efficiently prepare micrograms of circular DNA from picogram input material. The DNA templates are prepared by rolling circle amplification (RCA) using bacteriophage Phi29 DNA polymerase. TempliPhi™ uses an isothermal method for the exponential amplification of circular DNA. Phi29 DNA polymerase is active at 30 °C, enabling amplification to be performed at this temperature without the need for thermal cycling. The TempliPhi™ protocol requires less than 20 minutes of hands-on time to amplify 96 samples from bacterial colonies.
Expand 2 Items
Recombinant Taq DNA Polymerase
Supplier: GE HEALTHCARE
For PCR and other procedures requiring DNA polymerase activity at elevated temperatures.
Expand 2 Items
Thiourea
Supplier: GE HEALTHCARE
Thiourea is a chaotrope used together with urea in the IPG strip rehydration to solubilise and denature proteins, and improve the solubility of membrane proteins.
Expand 1 Items
Amersham Cy3 and Cy5 Maleimide Mono-Reactive Dye 5-Packs, Cytiva
Supplier: GE HEALTHCARE
Mono-functional maleimides are particularly suitable for the selective labelling of molecules containing free sulfhydryl groups, such as cysteine residues in proteins and peptides and oligonucleotides.
Expand 1 Items
Gel filtration media, Sephadex™ G-25
Supplier: GE HEALTHCARE
Sephadex™ G-25 is well established gel filtration medium for desalting and buffer exchange in industrial applications.
Expand 7 Items
Columns, SOURCE™ 15S PE
Supplier: GE HEALTHCARE
Source 15S 4.6/100 PE is a strong cation exchanger prepacked in a Tricorn column for intermediate lab-scale purification and large-scale polishing of biomolecules with ion exchange chromatography.
Expand 1 Items
Affinity chromatography columns, GSTrap™ 4B
Supplier: GE HEALTHCARE
GSTrap 4B columns are prepacked Glutathione Sepharose 4B columns for convenient, high capacity one-step purification of glutathione S-transferase (GST) tagged proteins.
Expand 3 Items
Accessories for Multiphor™ II electrophoresis system
Supplier: GE HEALTHCARE
IEF electrode strip, For: Multiphor™ II electrophoresis unit
Expand 2 Items
Tricorn Empty Chromatography Columns
Supplier: GE HEALTHCARE
Tricorn empty columns are for high resolution small-scale chromatography at pressures up to 50 bar (Tricorn 10) or 100 (Tricorn 5).
Expand 12 Items
Buffers for Biacore Systems
Supplier: GE HEALTHCARE
Buffers developed and verified to work in Biacore™ systems.
Expand 9 Items
Anion exchange chromatography column, HiScreen™ Capto™ Q
Supplier: GE HEALTHCARE
HiScreen Capto Q is a column packed with a strong anion exchange modern resin, combining speed and capacity. Suitable for process development.
Expand 1 Items
PBS buffer
Supplier: GE HEALTHCARE
Phosphate buffered saline solution, available with or without detergent, recommended as running buffer for small molecule analysis in Biacore systems. Concentrated stock solution, yielding pH 7,4 when diluted 10X.
Expand 1 Items
Columns, PD SpinTrap™ G-25
Supplier: GE HEALTHCARE
PD SpinTrap G-25 is a single-use column for cleanup of large biomolecules.
Expand 1 Items
Columns, PD MiniTrap™ G-25
Supplier: GE HEALTHCARE
PD MiniTrap G-25 columns are prepacked, single-use gravity columns for desalting, buffer exchange, and sample cleanup.
Expand 1 Items
Cation exchange chromatography column, HiPrep™ SP FF
Supplier: GE HEALTHCARE
HiPrep™ SP FF are ready to use strong cation exchange columns prepacked with SP Sepharose™ Fast Flow for fast, preparative separations of proteins and other biomolecules using ion exchange (IEX) chromatography.
Expand 1 Items
Affinity chromatography column, HiPrep™ Heparin FF
Supplier: GE HEALTHCARE
HiPrep Heparin FF columns are well suited for capture or intermediate purification of proteins with affinity for heparin.
Expand 1 Items
Protein A Mag Sepharose
Supplier: GE HEALTHCARE
Protein A Mag Sepharose magnetic beads are designed to simplifying enrichment of target proteins via immunoprecipitation or pull-down assays used to detect physical interactions between two or more proteins.
Expand 2 Items
Anion exchange chromatography column, HiPrep™ IEX Q Sepharose™ XL
Supplier: GE HEALTHCARE
HiPrep™ Q XL 16/10 is a prepacked, ready to use column for ion exchange chromatography.
Expand 1 Items
Expression vectors, pGEX
Supplier: GE HEALTHCARE
The pGEX vectors have an expanded multiple cloning site (MCS) that contains six restriction sites. The expanded MCS facilitates the unidirectional cloning of cDNA inserts obtained from libraries constructed using many available lambda vectors. pGEX-6P-1, pGEX-6P-2, and pGEX-6P-3 each encode the recognition sequence for site-specific cleavage by PreScission Protease between the GST domain and the multiple cloning site. pGEX-4T-1, pGEX-4T-2, and pGEX-4T-3 are derived from pGEX-2T and contain a Thrombin recognition site. pGEX-5X-1, pGEX-5X-2, and pGEX5X-3 are derivatives of pGEX-3X and possess a Factor Xa recognition site.
Expand 6 Items
Magnetic beads, His Mag Sepharose® Ni
Supplier: GE HEALTHCARE
His Mag Sepharose® Ni are magnetic beads designed for rapid, small-scale purification and screening of histidine-tagged proteins from different sources.
Expand 2 Items
Blotting Papers for Semi-Dry Blotters
Supplier: GE HEALTHCARE
Blotting paper, Sheets, 210×260 mm
Expand 2 Items
Cell culture reagents, microcarriers, Cytopore 1
Supplier: GE HEALTHCARE
Cytopore1 macroporous microcarriers are principally designed for use in suspension culture systems for growth of adherent recombinant Chinese Hamster Ovary (CHO) cells and the production of recombinant proteins.
Expand 1 Items
Cell culture reagents, microcarriers, Cytopore 2
Supplier: GE HEALTHCARE
Cytopore 2 macroporous microcarriers are principally designed for use in suspension culture systems for growth of adherent diploid cells requiering a higher surface charge and the production of recombinant proteins.
Expand 1 Items
Ion exchange chromatography media, Capto™ DEAE
Supplier: GE HEALTHCARE
Capto™ DEAE is a strong anion exchange bioprocessing medium, designed to meet the demands of modern large-scale manufacturers for fast, efficient, and cost-effective capture and intermediate protein purification when high volume throughput is essential.
Expand 2 Items
HiLoad Superdex columns, 75 PG
Supplier: GE HEALTHCARE
Superdex prep grade (pg) is produced by covalent bonding of dextran to highly cross-linked agarose.The separation properties of these media are determined by the dextran component
Expand 2 Items
Ion exchange chromatography media, Capto™ Q ImpRes
Supplier: GE HEALTHCARE
Capto™ Q ImpRes is a strong anion exchange bioprocess medium, designed to meet the demands of modern large-scale manufacturers for fast, efficient, and cost-effective intermediate and polishing protein purification.
Expand 2 Items
Hydrophobic interaction chromatography media, Capto™ Phenyl (high sub)
Supplier: GE HEALTHCARE
Capto™ Phenyl (high sub) is used in the capture and intermediate stages of protein purification.
Expand 1 Items
Affinity chromatography columns, HiTrap™ TALON® crude
Supplier: GE HEALTHCARE
HiTrap TALON® crude 1 and 5 ml columns allow for rapid separations and easy scale-up with a minimum of sample preparation and equipment.
Expand 2 Items
Anion exchange chromatography columns, HiTrap™ Capto™ Q ImpRes
Supplier: GE HEALTHCARE
HiTrap™ Capto™ Q ImpRes is a strong anion exchanger prepacked with BioProcess Capto™ ImpRes media for screening and small-scale protein purifications using ion exchange chromatography (IEX).
Expand 2 Items
Dye terminator removal, illustra™ AutoSeq™ G-50 columns
Supplier: GE HEALTHCARE
illustra™ AutoSeq™ G-50 columns are specifically designed to remove fluorescent dye-terminators from sequencing reactions prior to analysis on automated sequencers. Effective purification is essential for high quality sequencing results since residual dye-terminators can obscure data. illustra™ AutoSeq™ G-50 consists of MicroSpin™ columns containing Sephadex™ G-50, pre-equilibrated in double-distilled water. This is important because even the small amount of salt in traditional buffers (such as TE buffer) can cause electrophoretic artifacts on salt-sensitive automated sequencers.