Ammonia solution 28.0 - 30.0% (NH₃ basis), AR Select® ACS for trace metal analysis, Macron Fine Chemicals™
:1336-21-6
:7664-41-7
:NH₃
:MFCD00066650
:35.05 g/mol
:32…37.7 °C (1013 hPa)
:–60…–57.5 °C
:0.88…0.91 g/cm³ (20 °C)
:Ambient
:215-647-6
:8,III
:Management of Change (MOC) category = N
:2672
:GHS05
:GHS07
:GHS09
Some Products May Appear Restricted
To ensure a smooth and speedy checkout, please log in to your account. Some items may show as restricted simply because you're not logged in.
If you do not have an account, you can register using our registration webform (https://www.avantorsciences.com/us/en/login/register)
If you're still seeing restrictions after logging in, certain products—like chemicals or medical devices—require additional account verification steps to be able to place an order. Some items may additionally require a specific license or customer documentation; additional documentation will be requested for these items prior to shipment.
- ACS - Assay (as NH₃):28.0 - 30.0 %
- Appearance:Passes Test
- ACS - Carbon Dioxide (CO₂):≤0.002 %
- ACS - Pyridine:Passes Test
- ACS - Residue after Ignition:≤0.002 %
- ACS - Substances Reducing Permanganate:Passes Test
- ACS - Specific Gravity at 60°/60°F:0.896 - 0.902
- Trace Impurities - Arsenic (As):≤3.000 ppm
- Chloride (Cl):≤0.5 ppm
- Trace Impurities - Heavy Metals:≤0.5 ppm
- Nitrate (NO₃):≤2 ppm
- Phosphate (PO₄):≤2 ppm
- Total Sulfur (as SO₄):≤2 ppm
- Determine by Flame Photometry & ICP - Aluminum (Al):≤0.100 ppm
- Determine by Flame Photometry & ICP - Barium (Ba):≤0.100 ppm
- Determine by Flame Photometry & ICP - Beryllium (Be):≤0.010 ppm
- Determine by Flame Photometry & ICP - Bismuth (Bi):≤0.010 ppm
- Determine by Flame Photometry & ICP - Boron (B):≤0.050 ppm
- Determine by Flame Photometry & ICP - Cadmium (Cd):≤0.100 ppm
- Determine by Flame Photometry & ICP - Calcium (Ca):≤0.100 ppm
- Determine by Flame Photometry & ICP - Chromium (Cr):≤0.050 ppm
- Determine by Flame Photometry & ICP - Cobalt (Co):≤0.050 ppm
- Determine by Flame Photometry & ICP - Copper (Cu):≤0.050 ppm
- Determine by Flame Photometry & ICP - Gallium (Ga):≤0.500 ppm
- Determine by Flame Photometry & ICP - Germanium (Ge):≤0.500 ppm
- Determine by Flame Photometry & ICP - Gold (Au):≤0.500 ppm
- Determine by Flame Photometry & ICP - Iron (Fe):≤0.100 ppm
- Determine by Flame Photometry & ICP - Lead (Pb):≤0.2 ppm
- Determine by Flame Photometry & ICP - Lithium (Li):≤0.050 ppm
- Determine by Flame Photometry & ICP - Magnesium (Mg):≤0.100 ppm
- Determine by Flame Photometry & ICP - Manganese (Mn):≤0.050 ppm
- Determine by Flame Photometry & ICP - Mercury (Hg):≤0.500 ppm
- Determine by Flame Photometry & ICP - Molybdenum (Mo):≤0.010 ppm
- Determine by Flame Photometry & ICP - Nickel (Ni):≤0.500 ppm
- Determine by Flame Photometry & ICP - Potassium (K):≤0.100 ppm
- Determine by Flame Photometry & ICP - Silicon (Si):≤0.100 ppm
- Determine by Flame Photometry & ICP - Silver (Ag):≤0.050 ppm
- Determine by Flame Photometry & ICP - Sodium (Na):≤0.500 ppm
- Determine by Flame Photometry & ICP - Strontium (Sr):≤0.100 ppm
- Determine by Flame Photometry & ICP - Thallium (Tl):≤0.050 ppm
- Determine by Flame Photometry & ICP - Tin (Sn):≤0.100 ppm
- Determine by Flame Photometry & ICP - Vanadium (V):≤0.010 ppm
- Determine by Flame Photometry & ICP - Zinc (Zn):≤0.100 ppm
- Determine by Flame Photometry & ICP - Zirconium (Zr):≤0.010 ppm