Order Entry
China
ContactUsLinkComponent
VWR® DO-220/DO-220 M, Dissolved Oxygen Meters, Handheld, with Optical sensor
VWR® DO-220/DO-220 M, Dissolved Oxygen Meters, Handheld, with Optical sensor
Supplier:  VWR Collection
Certificates
undefined
VWR® DO-220/DO-220 M, Dissolved Oxygen Meters, Handheld, with Optical sensor
Supplier:  VWR Collection

Some Products May Appear Restricted

To ensure a smooth and speedy checkout, please log in to your account. Some items may show as restricted simply because you're not logged in.

If you do not have an account, you can register using our registration webform (https://www.avantorsciences.com/us/en/login/register)

 

If you're still seeing restrictions after logging in, certain products—like chemicals or medical devices—require additional account verification steps to be able to place an order. Some items may additionally require a specific license or customer documentation;  additional documentation will be requested for these items prior to shipment. 

Specifications

  • Catalog No:
  • VWRI664-0226
  • VWRI664-0225
  • VWRI664-0227
  • VWRI664-0168
  • VWRI664-0170
  • VWRI664-0169
  • Model:
  • DO 220 M
  • DO 220 M
  • DO 220 M
  • DO 220
  • DO 220
  • DO 220
  • DO accuracy:
  • ±1,5% of the reading or ±1,5 % (air saturation), whichever is greater
    ±1,5% of the reading or ±0,15 ppm, whichever is greater
  • ±1,5% of the reading or ±1,5 % (air saturation), whichever is greater
    ±1,5% of the reading or ±0,15 ppm, whichever is greater
  • ±1,5% of the reading or ±1,5 % (air saturation), whichever is greater
    ±1,5% of the reading or ±0,15 ppm, whichever is greater
  • ±1,5% of the reading or ±1,5 % (air saturation), whichever is greater
    ±1,5% of the reading or ±0,15 ppm, whichever is greater
  • ±1,5% of the reading or ±1,5 % (air saturation), whichever is greater
    ±1,5% of the reading or ±0,15 ppm, whichever is greater
  • ±1,5% of the reading or ±1,5 % (air saturation), whichever is greater
    ±1,5% of the reading or ±0,15 ppm, whichever is greater
  • DO concentration:
  • 0 - 20 mg/L
  • 0 - 20 mg/L
  • 0 - 20 mg/L
  • 0 - 20 mg/L
  • 0 - 20 mg/L
  • 0 - 20 mg/L
  • DO concentration resolution:
  • 0,1%; 0,01 mg/L
  • 0,1%; 0,01 mg/L
  • 0,1%; 0,01 mg/L
  • 0,1%; 0,01 mg/L
  • 0,1%; 0,01 mg/L
  • 0,1%; 0,01 mg/L
  • DO saturation:
  • 0 - 200 %
  • 0 - 200 %
  • 0 - 200 %
  • 0 - 200 %
  • 0 - 200 %
  • 0 - 200 %
  • DO barometric pressure range:
  • 375 - 825 mmHg
  • 375 - 825 mmHg
  • 375 - 825 mmHg
  • 375 - 825 mmHg
  • 375 - 825 mmHg
  • 375 - 825 mmHg
  • DO calibration:
  • Saturated air; 1 or 2 points with a zero % value
  • Saturated air; 1 or 2 points with a zero % value
  • Saturated air; 1 or 2 points with a zero % value
  • Saturated air; 1 or 2 points with a zero % value
  • Saturated air; 1 or 2 points with a zero % value
  • Saturated air; 1 or 2 points with a zero % value
  • Temperature range:
  • 0...50 °C
  • 0...50 °C
  • 0...50 °C
  • 0...50 °C
  • 0...50 °C
  • 0...50 °C
  • Temperature resolution:
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • Temperature accuracy:
  • ±0,3 °C
  • ±0,3 °C
  • ±0,3 °C
  • ±0,3 °C
  • ±0,3 °C
  • ±0,3 °C
  • Display:
  • Segmented LCD
  • Segmented LCD
  • Segmented LCD
  • Segmented LCD
  • Segmented LCD
  • Segmented LCD
  • Outputs:
  • Micro USB
  • Micro USB
  • Micro USB
  • -
  • -
  • -
  • Power supply:
  • One 9 V battery
  • One 9 V battery
  • One 9 V battery
  • One 9 V battery
  • One 9 V battery
  • One 9 V battery
  • Compliance:
  • IP 67
  • IP 67
  • IP 67
  • IP 67
  • IP 67
  • IP 67
  • Data logging capacity:
  • 250 data sets
  • 250 data sets
  • 250 data sets
  • 50 data sets
  • 50 data sets
  • 50 data sets
  • W×D×H:
  • 78×37×184 mm
  • 78×37×184 mm
  • 78×37×184 mm
  • 78×37×184 mm
  • 78×37×184 mm
  • 78×37×184 mm
  • Weight:
  • 0,272 kg
  • 0,272 kg
  • 0,272 kg
  • 0,272 kg
  • 0,272 kg
  • 0,272 kg

Specifications

Related Information