In-line filter cartidges, low pressure
Supplier: VICI JOUR RESEARCH
Filters are constructed of PTFE and CTFE, with a type 316 stainless low pressure drop screen. The inner design of the cartridge ensures the equal distribution of the solvent to the screen.
Expand 3 Items
Adapters
Supplier: VICI JOUR RESEARCH
These PEEK adapters connect standard LC fittings to standard LC ports, usable with most common organic and inorganic HPLC solvents without risking corrosion, metal contamination, or protein degradation.
Expand 10 Items
Chromatography tubing, stainless
Supplier: VICI JOUR RESEARCH
SS316, premium grade, seamless.
Expand 3 Items
Accessories for Sample Loops for Rheodyne® Valves, Stainless Steel
Supplier: VICI JOUR RESEARCH
Stainless steel ferrules, 2-step Rheodyne type, 1/16"
Expand 4 Items
Flanged fingertight nuts
Supplier: VICI JOUR RESEARCH
Fiberglass reinforced PP with PP washers. A number of chromatography systems still require or prefer flanged connections. When the tubing is flanged, the washer never comes in contact with the mobile phase.
Expand 4 Items
Sample loops for Valco valves
Supplier: VICI JOUR RESEARCH
These VICI Jour sample loops are made of high quality stainless steel 316.
Expand 8 Items
Pliers for stainless steel tubing
Supplier: VICI JOUR RESEARCH
The pliers type of cutter can be used for quick cuts for non-critical applications or at hard to get places.
Expand 1 Items
Sample loops for Rheodyne® valves
Supplier: VICI JOUR RESEARCH
These PEEK sample loops contain no metals or other extractable compounds. Therefore, no foreign materials will be introduced into the system. Softener free PE caps are used to avoid the contamination of the tubing. Particularly suited for separations involving proteins, peptides, nucleic acids or other samples of biological origin as well as in IC systems where metal traces may interact with ionic samples or release transition metals that may deactivate ion exchange columns.
Expand 1 Items
In-line filters, high pressure
Supplier: VICI JOUR RESEARCH
Filtro in linea, PEEK, Conf: 1
Expand 5 Items
Last drop filters/spargers
Supplier: VICI JOUR RESEARCH
The Last Drop filter/sparger combines filtration and sparging in a single unit. The PTFE housing contains a mobile phase filter with either a stainless steel or PTFE filter element. Connect the solvent line to the stepped connector, which accommodates 1,5, 2,2, and 3,5 mm ID tubing. A 1/4"-28 fitting connector connects a 1/8" helium line connects to the 10 µm sparger. Both connectors are PEEK.
Expand 6 Items
One-piece hex-head fittings
Supplier: VICI JOUR RESEARCH
Peek one-piece hex-head fittings, with their integrated ferrule, are easy to use with the valve-tool and the colour-it colour-coded finger-tight adapters. PEEK one-piece hex-head fittings are available in short and long versions.
Expand 2 Items
Caps
Supplier: VICI JOUR RESEARCH
These caps top bottles are available with two, three, or four colour-coded 1/4-28 thread for ¹/₈ or ¹/₁₆" O.Ø tubing.
Expand 18 Items
Accessories for safety caps, GL 45 threads
Supplier: VICI JOUR RESEARCH
O-ring, FEP coated, GL45 thread
Expand 1 Items
Safety cap
Supplier: VICI JOUR RESEARCH
This cap can be used for helium sparging and for delivering HPLC mobile phases. The tubing ports are made so that you push the tubing through the hole, while 1/4-28 fittings provide the best connection. Unused ports can be plugged as required.
Expand 1 Items
Frits, titanium, Unidense type
Supplier: VICI JOUR RESEARCH
Titanium frits are preferred over stainless steel frits for the application related to the analysis of sensitive substances such as biomolecules.
Expand 8 Items
PEEK unions
Supplier: VICI JOUR RESEARCH
VICI Jour PEEK unions are usable with most common HPLC solvents (organic and inorganic) without the risk of corrosion, metal contamination, or protein degradation that might occur with stainless steel. Connections to these PEEK unions can be made with any 10 to 32 fitting that uses a polymeric ferrule. The unions use the standardized Valco fitting details with smooth transition of the taper into the threaded part.
Expand 19 Items
Low pressure tees and crosses, PEEK
Supplier: VICI JOUR RESEARCH
Connectors for low pressure applications are machined from PEEK.
Expand 16 Items
Sample loops for Valco valves
Supplier: VICI JOUR RESEARCH
These sample loops are made from PEEK tubing and fittings. Mechanically strong, chemically inert polymer ideal for HPLC applications. Softener-free polyethylene caps are used to avoid contamination of the tubing.
Expand 8 Items
Sample loops for Cheminert® valves, stainless steel
Supplier: VICI JOUR RESEARCH
These VICI Jour sample loops are made of high quality stainless steel 316.
Expand 8 Items
Safety caps, GL 45 threads
Supplier: VICI JOUR RESEARCH
GL 45 safety caps seal to the bottle with an O-ring (EPDM) which is resistant to commonly used HPLC solvents. If improved chemical resistance is required (e.g. for halogenated hydrocarbons), order an FEP-coated O-ring separately.
Expand 9 Items
Cutter for stainless steel tubing, cutting wheel type
Supplier: VICI JOUR RESEARCH
This is the ideal tool for cutting ¹/₁₆ and ¹/₈" stainless steel tubing, leaving smooth, uniform cuts requiring a minimum of deburring and/or reaming.
Expand 1 Items
Chromatography tubing, PFA
Supplier: VICI JOUR RESEARCH
These PFA (perfluoro alkoxy) tubing has excellent chemical stability and mechanical strength.
Expand 13 Items
ChromBox kit
Supplier: VICI JOUR RESEARCH
The ChromBox is an all-purpose analytical spare parts kit for HPLC. It contains the most often used spare parts made both of high quality Type 316L SS as well as PEEK and PTFE.
Expand 9 Items
Accessories for waste caps
Supplier: VICI JOUR RESEARCH
Collapsible ferrule, for 1/4" OD tubing
Expand 6 Items
Accessories for safety air inlet valves
Supplier: VICI JOUR RESEARCH
Replacement cellulose filter, PP, Dimensioni pori: 0,2 µm, Ø: 15 mm
Expand 2 Items
Raccordi a chiusura manuale
Supplier: VICI JOUR RESEARCH
PEEK two-piece fingertight fittings. Fits any 10 to 32 fitting. Works with any ¹/₁₆'' OD tubing.
Expand 2 Items
Mobile phase filters
Supplier: VICI JOUR RESEARCH
These filters made from stainless steel 316L protect HPLC systems from small particles in the mobile phase.
Expand 3 Items
End plug
Supplier: VICI JOUR RESEARCH
Plugs can be used to close off an unused port in a valve or manifold. Size ¹/₄ - 28".