Solid phase extraction cartridges, Bond Elut™ Diol

Supplier: VARIAN

Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ C8

Supplier: VARIAN

Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.

Expand 23 Items
Loading...
Empty solid phase extraction cartridges with two frits, Bond Elut™

Empty solid phase extraction cartridges with two frits, Bond Elut™

Supplier: VARIAN

Clean PP reservoirs contain two PP frits pre-inserted, an ideal configuration for simple filtration.

Expand 7 Items
Loading...

Accessories for solid phase extraction cartridges, Bond Elut™ SPEC

Supplier: VARIAN

Bond Elut™, Environmental disk manifold

Expand 3 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ C18

Solid phase extraction cartridges, Bond Elut™ C18

Supplier: VARIAN

Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.

Expand 43 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ NEXUS and NEXUS WCX

Supplier: VARIAN

Bond Elut™ NEXUS is an ultra-clean polymeric sorbent which has bi-modal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no pre-conditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine.

Based on the same base polymer technology, Bond Elut™ NEXUS WCX is a weak cation exchange sorbent that offers extra selectivity for analytes, such as quaternary ammonium drugs and anabolic steroids.

Expand 8 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Plexa PCX

Supplier: VARIAN

Bond Elut™ Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut™ Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removes neutral and acidic interferences from the matrix, concentrates basic analytes and therefore improves sensitivity in the determination of basic compounds.

Expand 11 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ SCX

Supplier: VARIAN

Bond Elut™ SCX is a strong cation exchanger with a very low pKa. Although the pKa is similar to Bond Elut™ PRS, the presence of the benzene ring in the functional group increases the potential for non-polar interactions. This non-polar characteristic becomes particularly important when conducting ion-exchange from aqueous systems, where selectivity towards compounds exhibiting cationic and non-polar character is seen.

Expand 24 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying

Supplier: VARIAN

Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.

Expand 5 Items
Loading...
Hazardous Waste Filtration System

Hazardous Waste Filtration System

Supplier: Merck

If your waste samples contain non-volatile or semi-volatile substances or metals, use this hazardous waste filtration system for saparation, extratction, and filtration. Developed in collaboration with the US Environmental Protection Agency (EPA), the system is designed specifically for the US EPA Extraction Procedure (EP) Toxicity Test and Toxicity Characteristic Leaching Procedure (TCLP). The device separates solid and liquid phases of waste samples for analysis.

Expand 3 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Tebufenpyrad

Supplier: Merck

Profenofos CRM may also be used as given below: Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. Gas chromatography-tandem mass spectrometry (GC-MS/MS) based analysis of 213 pesticide residues in soybean after their extraction by QuEChERS procedure. Detection of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Multi-residue analysis of 160 multiclass pesticides using ethyl acetate (EtAC)/n. hexane mixture for extraction from chamomile thyme and marjoram samples and their analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). Simultaneous determination of 34 pesticides in various environmental water samples by dispersive liquid-liquid microextraction (DLLME) technique in combination with gas chromatography-mass spectrometry(GC-MS/MS). Quantitation of 40 multi-class insecticides and fungicides in 81 apple samples by using gas- and liquid- chromatography-mass following a QuEChERS-based extraction.

Expand 1 Items
Loading...

SampliQ SPE cartridges

Supplier: AGILENT HEWLETT PACKARD

High quality SampliQ SPE (Solid Phase Extraction) products help the user confidently extract and concentrate samples from complex matrices, ensuring fast, accurate, and reproducible results from the very first step. The SampliQ line includes polymers, silica and non-silica options to meet user's specific SPE needs.

Expand 2 Items
Loading...

SPE cartridges, Dionex™, SolEx™

Supplier: DIONEX

Dionex™ SolEx™ SPE cartridges are designed for use with Dionex AutoTrace 280 SPE system or other SPE instrumentation and vacuum manifolds. They are suitable for extracting organic pollutants from a liquid sample off-line using a solid-phase adsorbent.

Expand 14 Items
Loading...
Accessories for 96-well Bond Elut™ plates

Accessories for 96-well Bond Elut™ plates

Supplier: VARIAN

96-well manifold, acrylic

Expand 6 Items
Loading...
Accessories for SPE plates, OMIX 96-well VersaPlate™

Accessories for SPE plates, OMIX 96-well VersaPlate™

Supplier: VARIAN

Piastra di base per provette VersaPlate™, 96 pozzetti

Expand 1 Items
Loading...
LH software, TRILUTION®

LH software, TRILUTION®

Supplier: GILSON LCMS

TRILUTION® LH provides a solution for customers using Windows 10 and is a comprehensive software package for seamless automation of all liquid handling and solid phase extraction (SPE) methods. With its intuitive interface, simple drag-and-drop method creation, and application simulation, it combines flexibility and ease of use.

Expand 1 Items
Loading...