VWR® pHenomenal® MD 8000 H Multi-Parameter Instruments, Handheld
Supplier: VWR Collection
Certificates
About this item
These digital meters combine six parameters in one instrument: pH, mV, temperature, conductivity, dissolved oxygen and turbidity. IDP technology optimises use and makes measurement easier (no need to recalibrate when changing the meter and no need to adjust the meter’s settings). The measured data is complete with serial number, settings and calibration data.
- One universal measuring channel
- Digital sensor recognition: The measured parameter and settings are recognised automatically
- Suitable for Intelligent Digital Probes (IDP)
- Suitable for measurements with cable length up to 100 metres
- 4500-point memory
- Easy to read backlit B/W graphic display
- Low energy consumption (1000 operating hours)
Ordering information: Additional probes for other parameters can be added. Please contact your local Avantor sales office for further information on other electrodes available.
Delivery: 665-0494 includes meter, case, stand, 4 LR06 batteries, short instructions, CD ROM with manual, 50 ml plastic beaker, 50 ml buffer 4, 50 ml buffer 7, plugin power supply, pH electrode pHenomenal IDP 7211 and USB cable.
665-0495 includes meter, case, stand, 4 LR06 batteries, short instructions, CD ROM with manual, 50 ml plastic beaker, 50 ml conductivity standard 0,01 mol/L KCl, conductivity cell IDP 761-C and USB cable.
665-0496 includes meter, case, stand, 4 LR06 batteries, short instructions, CD ROM with manual, 50 ml plastic beaker, optical DO sensor OPOX11-3 and USB cable.
665-0495 includes meter, case, stand, 4 LR06 batteries, short instructions, CD ROM with manual, 50 ml plastic beaker, 50 ml conductivity standard 0,01 mol/L KCl, conductivity cell IDP 761-C and USB cable.
665-0496 includes meter, case, stand, 4 LR06 batteries, short instructions, CD ROM with manual, 50 ml plastic beaker, optical DO sensor OPOX11-3 and USB cable.
Specifications
- Catalog No:
- 665-0494
- 665-0496
- 665-0495
- pH - range:
- 0 - 14
- 0 - 14
- 0 - 14
- pH - risoluzione:
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- pH - accuratezza:
- ±0,1, ±0,01, ±0,005
- ±0,1, ±0,01, ±0,005
- ±0,1, ±0,01, ±0,005
- mV - range:
- ±2500; ±1200
- ±2500; ±1200
- ±2500; ±1200
- mV - risoluzione:
- 0,1; 1
- 0,1; 1
- 0,1; 1
- mV - accuratezza:
- ±0,3; ±1
- ±0,3; ±1
- ±0,3; ±1
- Intervallo di conducibilità:
- 0,01 µS/cm - 1000 mS/cm (depending on sensor)
- 0,01 µS/cm - 1000 mS/cm (depending on sensor)
- 0,01 µS/cm - 1000 mS/cm (depending on sensor)
- Precisione della conducibilità:
- ±0,5% of value
- ±0,5% of value
- ±0,5% of value
- Costante di cella di conducibilità:
- Automatic
- Automatic
- Automatic
- Resistività - range:
- 1 Ωcm - 20 MΩcm (depending on sensor)
- 1 Ωcm - 20 MΩcm (depending on sensor)
- 1 Ωcm - 20 MΩcm (depending on sensor)
- Salinità - range:
- 0 - 70
- 0 - 70
- 0 - 70
- TDS - risoluzione:
- 0 mg/L - 199,9 g/L
- 0 mg/L - 199,9 g/L
- 0 mg/L - 199,9 g/L
- OD concentrazione:
- 0,00 - 20,00 / 0,0 - 50,0 mg/L
- 0,00 - 20,00 / 0,0 - 50,0 mg/L
- 0,00 - 20,00 / 0,0 - 50,0 mg/L
- OD - saturazione:
- 0,0 - 200,0; 0 - 500 %
- 0,0 - 200,0; 0 - 500 %
- 0,0 - 200,0; 0 - 500 %
- Range di temperatura:
- Auto: −5...+105 °C
- Auto: −5...+105 °C
- Auto: −5...+105 °C
- Risoluzione della temperatura:
- 0,1 °C
- 0,1 °C
- 0,1 °C
- Accuratezza della temperatura:
- ±0,2 K
- ±0,2 K
- ±0,2 K
- Display:
- Backlit B/W graphic LCD
- Blacklit B/W graphic LCD
- Blacklit B/W graphic LCD
- Datalog - funzione di registrazione:
- Manual/time controlled
- Manual/time controlled
- Manual/time controlled
- Capacità della memoria:
- Up to 4500 data sets in automatic
- Up to 4500 data sets in automatic
- Up to 4500 data sets in automatic
- Capacità memoria:
- 4500 points
- 4500 points
- 4500 points
- Protezione IP:
- IP 67
- IP 67
- IP 67
- Interfacce:
- 1 measurement input
- 1 measurement input
- 1 measurement input
- Temperatura di riferimento:
- 20/25 °C
- 20/25 °C
- 20/25 °C
- Interfaccia:
- Mini USB-B (USB 1.1) for data downloads
- Mini USB-B (USB 1.1) for data downloads
- Mini USB-B (USB 1.1) for data downloads
- Parametro:
- pH, mV, temperature, conductivity, dissolved oxygen, turbidity
- pH, mV, temperature, conductivity, dissolved oxygen, turbidity
- pH, mV, temperature, conductivity, dissolved oxygen, turbidity
- Calibrazione:
- Anycal 5-point customer buffer calibration
- Anycal 5-point customer buffer calibration
- Anycal 5-point customer buffer calibration
- Punti di calibrazione:
- 1 to 5 (automatic buffer recognition)
- 1 to 5 (automatic buffer recognition)
- 1 to 5 (automatic buffer recognition)
Specifications
pH electrode
Product Information
Frequently Bought Together