Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216
About this item
This benchtop meter is ideal for a wide range of applications and advanced pH and dissolved oxygen analysis in the lab. It offers two measuring channels allowing users to measure pH and dissolved oxygen simultaneously or view each channel separately. Can be used with RDO optical or polarographic DO probes.
- Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
- Measurement stability indicator and selectable read modes - Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
- Data log collects and date/time stamps up to 2000 measurement sets with optional sample ID and user ID
- Calibration log stores ten most recent calibrations
- Non volatile meter memory ensures your data and settings are protected, even with loss of power
- Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
- Flexible power options with universal power adapter or optional AA batteries
- Three year meter warranty
IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.
Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two.
Perform up to a five point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values and calibration editing option that allows individual points to be fixed without a full recalibration. Calibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options.
Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings.
: Supplied with electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate.
The kit additionally includes: 8157BNUMD ROSS Ultra Triode refillable epoxy-body pH/ATC electrode, 083005MD Polarographic DO sensor with calibration sleeve, ROSS pH buffer and storage solution kit, DO sensor maintenance kit and BOD adapter, funnel and stirrer.
2 Options Available Below
Product Details & Documents
This benchtop meter is ideal for a wide range of applications and advanced pH and dissolved oxygen analysis in the lab. It offers two measuring channels allowing users to measure pH and dissolved oxygen simultaneously or view each channel separately. Can be used with RDO optical or polarographic DO probes.
- Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
- Measurement stability indicator and selectable read modes - Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
- Data log collects and date/time stamps up to 2000 measurement sets with optional sample ID and user ID
- Calibration log stores ten most recent calibrations
- Non volatile meter memory ensures your data and settings are protected, even with loss of power
- Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
- Flexible power options with universal power adapter or optional AA batteries
- Three year meter warranty
IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.
Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two.
Perform up to a five point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values and calibration editing option that allows individual points to be fixed without a full recalibration. Calibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options.
Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings.
: Supplied with electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate.
The kit additionally includes: 8157BNUMD ROSS Ultra Triode refillable epoxy-body pH/ATC electrode, 083005MD Polarographic DO sensor with calibration sleeve, ROSS pH buffer and storage solution kit, DO sensor maintenance kit and BOD adapter, funnel and stirrer.
Specifications for Product Family
Specifications
- Catalog No:
- 665-0273
- 665-0274
- Modello:
- A216
- A216
- pH - range:
- –2,000...+20,000
- –2,000...+20,000
- pH - risoluzione:
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- pH - accuratezza:
- ±0,002
- ±0,002
- pH - calibrazione:
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- mV - range:
- ±2000,0
- ±2000,0
- mV - risoluzione:
- 0,1
- 0,1
- mV - accuratezza:
- ±0,2 mV or ±0,05% of reading, whichever is greater
- ±0,2 mV or ±0,05% of reading, whichever is greater
- OD concentrazione:
- 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
- 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
- OD - risoluzione:
- 0,1/0,01 mg/L
- 0,1/0,01 mg/L
- OD - saturazione:
- 0 - 600% (polarographic); 0 - 500% (RDO)
- 0 - 600% (polarographic); 0 - 500% (RDO)
- OD accuratezza:
- Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L) - Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
- OD calibrazione:
- Water-saturated air, air saturated water, manual (Winkler) and zero point
- Water-saturated air, air saturated water, manual (Winkler) and zero point
- OD - range di pressione barometrica:
- Automatic or manual, 450 - 850 mm Hg
- Automatic or manual, 450 - 850 mm Hg
- Range dell'ossigeno disciolto:
- 0,00 - 90,00 mg/L
- 0,00 - 90,00 mg/L
- Range di temperatura:
- –5,0...+50,0 °C
- –5,0...+50,0 °C
- Risoluzione della temperatura:
- 0,1 °C
- 0,1 °C
- Accuratezza della temperatura:
- ±0,1 °C
- ±0,1 °C
- Temperatura - compensazione:
- Automatic or manual
- Automatic or manual
- Range di pressione:
- 400 - 850 mm Hg
- 400 - 850 mm Hg
- Display:
- Graphic LCD with backlight
- Graphic LCD with backlight
- Tipo di batteria:
- 4 AA (sold separately)
- 4 AA (sold separately)
- Durata batteria:
- 800 h
- 800 h
- Alimentazione:
- AC adapter (included) or 4 AA batteries
- AC adapter (included) or 4 AA batteries
- Conformità:
- CE, TUV 3-1, FCC Class A
- CE, TUV 3-1, FCC Class A
- Range della temperatura di esercizio:
- 5...45 °C (ambient)
- 5...45 °C (ambient)
- Datalog - funzione di registrazione:
- Manual/Automatic with AUTO-READ™
- Manual/Automatic with AUTO-READ™
- Capacità della memoria:
- 2000 with date and time stamp
- 2000 with date and time stamp
- Capacità memoria:
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Lingue:
- English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
- English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
- Protezione IP:
- IP 54
- IP 54
- Interfacce:
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
- Uscite:
- RS232, USB
- RS232, USB
- Ingresso:
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
- Allarme:
- High/low limit alarm, calibration due alarm
- High/low limit alarm, calibration due alarm
- N. di canali:
- 2
- 2
- Calibrazione:
- pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
- pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
- Punti di calibrazione:
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- L×P×A:
- 240×180×110 mm
- 240×180×110 mm
- Peso:
- 0,9 kg
- 0,9 kg
Specifications
Product Family Options
Product Information
- DescrizioneAvailabilityPrice
- Specifications:
More
Specifications
Cat. No.665-0273ModelloA216pH - range–2,000...+20,000pH - risoluzione0,1/0,01/0,001pH - accuratezza±0,002pH - calibrazioneUp to 5 points; Automatic buffer recognition (USA/NIST and DIN)mV - range±2000,0mV - risoluzione0,1mV - accuratezza±0,2 mV or ±0,05% of reading, whichever is greaterOD concentrazione0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)OD - risoluzione0,1/0,01 mg/LOD - saturazione0 - 600% (polarographic); 0 - 500% (RDO)OD accuratezzaPolarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)OD calibrazioneWater-saturated air, air saturated water, manual (Winkler) and zero pointOD - range di pressione barometricaAutomatic or manual, 450 - 850 mm HgRange dell'ossigeno disciolto0,00 - 90,00 mg/LRange di temperatura–5,0...+50,0 °CRisoluzione della temperatura0,1 °CAccuratezza della temperatura±0,1 °CTemperatura - compensazioneAutomatic or manualRange di pressione400 - 850 mm HgDisplayGraphic LCD with backlightTipo di batteria4 AA (sold separately)Durata batteria800 hAlimentazioneAC adapter (included) or 4 AA batteriesConformitàCE, TUV 3-1, FCC Class ARange della temperatura di esercizio5...45 °C (ambient)Datalog - funzione di registrazioneManual/Automatic with AUTO-READ™Capacità della memoria2000 with date and time stampCapacità memoriaNon-volatile memory preserves data log, calibration log and meter settingsLingueEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software updateProtezione IPIP 54InterfacceBNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)UsciteRS232, USBIngressoBNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)AllarmeHigh/low limit alarm, calibration due alarmN. di canali2CalibrazionepH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperaturePunti di calibrazione1 point relative mV (RmV) mode, 1 point ORP modeL×P×A240×180×110 mmPeso0,9 kg - Bench pH/DO meter Orion Star A216, kit incl. ROSS Ultra Triode pH/ATC probe and polarographic DO probeLog in for availability1 * 1 STSFr. 3’240.00Specifications:
More
Specifications
Cat. No.665-0274ModelloA216pH - range–2,000...+20,000pH - risoluzione0,1/0,01/0,001pH - accuratezza±0,002pH - calibrazioneUp to 5 points; Automatic buffer recognition (USA/NIST and DIN)mV - range±2000,0mV - risoluzione0,1mV - accuratezza±0,2 mV or ±0,05% of reading, whichever is greaterOD concentrazione0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)OD - risoluzione0,1/0,01 mg/LOD - saturazione0 - 600% (polarographic); 0 - 500% (RDO)OD accuratezzaPolarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)OD calibrazioneWater-saturated air, air saturated water, manual (Winkler) and zero pointOD - range di pressione barometricaAutomatic or manual, 450 - 850 mm HgRange dell'ossigeno disciolto0,00 - 90,00 mg/LRange di temperatura–5,0...+50,0 °CRisoluzione della temperatura0,1 °CAccuratezza della temperatura±0,1 °CTemperatura - compensazioneAutomatic or manualRange di pressione400 - 850 mm HgDisplayGraphic LCD with backlightTipo di batteria4 AA (sold separately)Durata batteria800 hAlimentazioneAC adapter (included) or 4 AA batteriesConformitàCE, TUV 3-1, FCC Class ARange della temperatura di esercizio5...45 °C (ambient)Datalog - funzione di registrazioneManual/Automatic with AUTO-READ™Capacità della memoria2000 with date and time stampCapacità memoriaNon-volatile memory preserves data log, calibration log and meter settingsLingueEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software updateProtezione IPIP 54InterfacceBNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)UsciteRS232, USBIngressoBNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)AllarmeHigh/low limit alarm, calibration due alarmN. di canali2CalibrazionepH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperaturePunti di calibrazione1 point relative mV (RmV) mode, 1 point ORP modeL×P×A240×180×110 mmPeso0,9 kg
Accessories
Product Information
- Catalog #DescrizionePerAvailabilityPrice
- ORIOSTARA-BEABenchtop meter-attached electrode stand (electrode holder arm and head), Orion™ Star A series, 360° motion (without weighted base)Orion Star A110 + A210 series, Orion Versa Star benchtop metersLog in for availability1 * 1 ST - SFr. 202.00
Product Information
- Catalog #DescrizioneAvailabilityPrice
- 662-1140Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cableLog in for availability1 * 1 SET - SFr. 94.40
Product Information
- Catalog #DescrizioneAvailabilityPrice
- 662-1547Spare universal power adapter for Thermo Scientific™ Orion™ Star A series benchtop and portable meters and legacy Orion™ Star and Star Plus series metersLog in for availability1 * 1 ST - SFr. 89.50
Product Information
- Catalog #DescrizioneAvailabilityPrice
- ORIOSTARA-HBOrion™ Star™ A Series weighted base for use with meter-attached electrode standLog in for availability1 * 1 ST - SFr. 69.60
Product Information
- Catalog #DescrizioneAvailabilityPrice
- ORIO1010053RS232 cable, for connecting a meter to a PC or printerLog in for availability1 * 1 ST - SFr. 56.10
Product Information
- Catalog #DescrizioneAvailabilityPrice
- ORIO1010005Cable adapter, for connecting the RS232 port of a meter to a USB portLog in for availability1 * 1 ST - SFr. 162.00