Temperature gradient plate for MFFT test
Informazioni su questo articolo
Temperature gradient plate for determining minimum film forming temperature (MFFT) test. The instrument can be used to define the white point/glass transition temperature of dispersion materials, synthetic resins, enamels and the blocking power and stacking capability of coated papers, foils, prints.
- Ground hard-chrome plated metal platen as to deposit the specimen
- Displays nominal and actual value of hot and cold side
- Electronic controller with digital display, temperature preselecting and overshoot protection
- Integrated membrane drying unit with flow meter
The temperature is controlled through an integrated digital controller with a digital display and measuring-point selector that covers the whole range. To determine the blocking power the specimens on the platen are weighed by defined loads to simulate the stacking capability.
MFFT 10: Includes 10 built-in temperature sensors and hinged transparent cover made of PMMA. Recommended standard cryostat type is C10K20.
MFFT 20: Includes 20 built-in temperature sensors and hinged transparent cover made of stainless steel and safety glass for temperatures up to +250 °C. Recommended standard cryostat type is KWK10.
W×D×H (with closed cover): 350×800×320 mm
Certifications: Conforms to DIN ISO 2115 – DIN 53366 – ASTM D 2354 – ASTM D 1465 – ISO 2115 – ISO/DIS 4622.
Informazioni per l'ordine: Optional cooling unit must be ordered separately.
2 varianti
Product Details & Documents
Temperature gradient plate for determining minimum film forming temperature (MFFT) test. The instrument can be used to define the white point/glass transition temperature of dispersion materials, synthetic resins, enamels and the blocking power and stacking capability of coated papers, foils, prints.
- Ground hard-chrome plated metal platen as to deposit the specimen
- Displays nominal and actual value of hot and cold side
- Electronic controller with digital display, temperature preselecting and overshoot protection
- Integrated membrane drying unit with flow meter
The temperature is controlled through an integrated digital controller with a digital display and measuring-point selector that covers the whole range. To determine the blocking power the specimens on the platen are weighed by defined loads to simulate the stacking capability.
MFFT 10: Includes 10 built-in temperature sensors and hinged transparent cover made of PMMA. Recommended standard cryostat type is C10K20.
MFFT 20: Includes 20 built-in temperature sensors and hinged transparent cover made of stainless steel and safety glass for temperatures up to +250 °C. Recommended standard cryostat type is KWK10.
W×D×H (with closed cover): 350×800×320 mm
Certifications: Conforms to DIN ISO 2115 – DIN 53366 – ASTM D 2354 – ASTM D 1465 – ISO 2115 – ISO/DIS 4622.
Informazioni per l'ordine: Optional cooling unit must be ordered separately.
Documents
TQC Company Video
Video
Product Family Options
Informazioni sul prodotto
- DisponibilitàPrice
- SIMEVF9600MFFT 10, temperature range −5...+80 °C, with a maximum gradient on surface of 20 °CMFFT 10, temperature range −5...+80 °C, with a maximum gradient on surface of 20 °CLog in per disponibilità1 * 1 STSFr. 29’350.00
- SIMEVF9700MFFT 20- Temperature range of −30...+250 °C with a maximum gradient on surface of 100 °CMFFT 20- Temperature range of −30...+250 °C with a maximum gradient on surface of 100 °CLog in per disponibilità1 * 1 STSFr. 46’060.00
I suggerimenti saranno personalizzati in base alle tue preferenze di acquisto solo se hai attivato "Migliora la mia esperienza di acquisto" nella pagina "Informazioni personali".
Altrimenti riceverai suggerimenti generici..



