Use the humidity/temperature probes (with an appropriate measuring instrument) for the reliable measurement of relative humidity and temperature.
10 varianti
Product Details & Documents
Use the humidity/temperature probes (with an appropriate measuring instrument) for the reliable measurement of relative humidity and temperature.
Product Family Options
Informazioni sul prodotto
- TipoRange di misuraAccuratezzaDisponibilitàPrice
- 620-1860Sonda di ricambio esterna per EBI 300 TE, Ø×L: 4×50 mm, TPC 300Sonda di ricambio esterna per EBI 300 TE, Ø×L: 4×50 mm, TPC 300TPC 300 (NTC)–35...+75 °CT: ±0,5 °C (–20…+40 °C); ±0,8 °C for the remaining measurement rangeLog in per disponibilità1 * 1 STSFr. 89.80
- 620-1861Sonda di ricambio esterna per EBI 310 TE, Ø×L: 5×50 mm, TPX 220Sonda di ricambio esterna per EBI 310 TE, Ø×L: 5×50 mm, TPX 220−200...+250 °CT: ±2,0 °C (–200…–100 °C); ±1,0 °C (–100 …–20 °C); ±0,2 °C (–20…+60 °C); ±0,5 °C (+60…+250 °C)Log in per disponibilità1 * 1 STSFr. 280.00
- 620-2394Sonda di ricambio esterna per EBI 310 TH, TPH 500Sonda di ricambio esterna per EBI 310 TH, TPH 500–30… +75 °C; 0 - 100 % RHRH: ±2% between 10 - 90% (at +25 °C); ±4 % for the remaining measuring range
T: ±0,5 °C (+20… +60 °C); ±0,8 °C for the remaining measuring rangeLog in per disponibilità1 * 1 STSFr. 313.00 - 620-2762External replacement probe for EBI 310TX- P1, Ø×L: 5×45 mm, blunt, with 3 m PTFE cableExternal replacement probe for EBI 310TX- P1, Ø×L: 5×45 mm, blunt, with 3 m PTFE cable−200...+200 °C—Log in per disponibilità1 * 1 STSFr. 135.00
- 620-2763External replacement probe for EBI 310TX- P2, Ø×L: 5×45 mm, blunt, with 3 m PTFE cableExternal replacement probe for EBI 310TX- P2, Ø×L: 5×45 mm, blunt, with 3 m PTFE cable−50...+180 °C—Log in per disponibilità1 * 1 STSFr. 135.00
- 620-2764External replacement probe for EBI 310TX- P3, Ø×L: 5×45 mm, blunt, with 1 m PTFE cableExternal replacement probe for EBI 310TX- P3, Ø×L: 5×45 mm, blunt, with 1 m PTFE cable−50...+180 °C—Log in per disponibilità1 * 1 STSFr. 135.00
- 620-2765External replacement probe for EBI 310TX- P4, Ø×L: 5×45 mm, blunt, with 3 m metal wrapped cableExternal replacement probe for EBI 310TX- P4, Ø×L: 5×45 mm, blunt, with 3 m metal wrapped cable100...400 °C—Log in per disponibilità1 * 1 STSFr. 433.00
- 620-2823External replacement probe for PT 1000, Ø×L: 5×50 mm, TPX 220-3External replacement probe for PT 1000, Ø×L: 5×50 mm, TPX 220-3−200...+250 °CT: ±2,0 °C (–200…–100 °C); ±1,0 °C (–100 …–20 °C); ±0,2 °C (–20…+60 °C); ±0,5 °C (+60…+250 °C)Log in per disponibilità1 * 1 STSFr. 280.00
- 620-2262Sonda di ricambio interna per EBI 300 TH, TPH 400Sonda di ricambio interna per EBI 300 TH, TPH 400TPH 300 (NTC, capacitive)–30… +70 °C; 0 - 100 % RHRH: ±3% between 10 - 90% (at +25 °C); ±5 % for the remaining measuring range
T: ±0,5 °C (+20… +40 °C); ±1 °C for the remaining measuring rangeLog in per disponibilità1 * 1 STSFr. 122.00 - 620-2761Replacement adapter for EBI 310 TX, type TPX 310