You searched for: Indicatori di sterilità
Changing appearances in color or pattern, the sterilization indicators visually show if cleaning conditions are passing or procedures have been completed. Eliminating any confusion or possibility instruments will not be sterile, indicators are used routinely in clinical and research environments where contamination elimination is crucial. With the temperature resistance required to endure the purification, the sterilization indicators are available in different forms such as tapes, ampoules, and sticks. Geobacillus stearothermophilus spores demonstrate a high resistance towards steam and vaporized hydrogen peroxide and are therefore used in BIs that monitor these sterilization processes.
Bioindicatore, Sterikon® plus
Supplier: Merck
I bioindicatori Sterikon® plus possono essere utilizzati per verificare il funzionamento delle autoclavi (15 minuti a 121°C). Possono essere utilizzati per valutare la sterilizzazione in autoclave di qualunque carico. Ad esempio, prodotti farmaceutici, in particolare prodotti in fiale, alimenti in scatola ecc.
Expand 2 Items
Biological indicators, self-contained tests, STERILtest
Supplier: LIOFILCHEM
Biological indicators for validating the sterilisation using steam sterilisation (autoclaves).
Expand 4 Items
Single Use Test Packs, Bowie and Dick Type
Supplier: VP Medical Packaging
Indicator di sterilità, Bowie-dick single use test pack (prime-pack)
Expand 1 Items
Biological indicators, stainless steel coupons, OXI CONTROL
Supplier: LIOFILCHEM
Biological indicators for validating the sterilisation using VHP in isolators.
Expand 18 Items
Biological indicators, ampoules for steam sterilisation, STERIL CONTROL
Supplier: LIOFILCHEM
Biological indicators for validating sterilisation using steam sterilisation (autoclaves).
Expand 4 Items
Biological indicators, strips
Supplier: LIOFILCHEM
Biological indicators for validating the sterilisation using steam sterilisation (autoclaves).
Expand 6 Items
Cleanroom autoclave indicator tape
Supplier: MICRONOVA
Saturated crepe paper/synthetic poly isoprene adhesive in plastic core. It is a proven method of positively confirming a completed sterilisation cycle in both gravity discharge and vacuum autoclaves. Green indicator lines change to black when proper levels of steam pressure and temperature have been achieved. After use, the tape removes quickly and completely, leaving minimal residue or staining.
Expand 6 Items
Biological indicators, spore suspensions
Supplier: LIOFILCHEM
Biological indicators for validating the sterilisation using steam (autoclaves), VHP (isolators), dry heat and irradiation processes.
Expand 10 Items
Lead-free steam indicator tapes, Comply™
Supplier: 3M MEDICAL
An exposure monitor that securely seals packs, and provides a visual assurance that the package has been exposed to the steam sterilisation process.
Expand 3 Items
Cleanroom labels, autoclavable
Supplier: Texwipe
Indicator di sterilità, Labels, Cleanroom labels, autoclavable, Lunghezza: 50 mm, Larghezza: 50 mm
Expand 1 Items
Chemical indicator strip, Comply™
Supplier: 3M MEDICAL
This steam chemical indicator offers a distinct off-white to dark brown/black color change when exposed to steam sterilization.
Expand 1 Items
Dry heat indicator tapes, Comply™
Supplier: 3M MEDICAL
This chemical indicator tape is designed for use as packaging tape and for the immediate identification of items exposed to dry heat processing.
Expand 1 Items
Sterilisation indicators
Supplier: Brand
This self-adhesive crepe indicator tape turns from white to brown upon autoclaving.
Expand 1 Items
Steam sterilisation indicator labels, Comply™ (SteriGage™)
Supplier: 3M MEDICAL
Integrating indicator for use in determining whether the process conditions necessary for sterilisation were met inside each pack. Can be used in all 118 to 138 °C (245 to 280 °F) steam sterilisation cycles.
Expand 1 Items
Indicatori per sterilizzazione a calore secco
Supplier: KARTELL
Nastro adesivo.
Expand 1 Items
Steam indicator tape, Comply™
Supplier: 3M MEDICAL
Indicator tapes are Class 1 process indicators used for exposure monitoring. They provide assurance to the operator handling the processed items that the pack has been exposed to the sterilisation process without the need to open the pack or check load control records. Optional tape dispensers are available for easy dispensing of indicator tapes.
Expand 1 Items
Nastri adesivi per autoclave
Supplier: PRECISION DYNAMICS TIMEM
Nastro adesivo bianco crespo, per l'utilizzo nelle autoclavi standard
Expand 3 Items
Super Rapid Readout Steam Challenge Pack 1496VX, 3M™ Attest™
Supplier: 3M MEDICAL
Twenty four minute Biological Indicator Challenge Pack for 132°C (270°F) 4 minute and 135°C (275°F) 3 minute Dynamic Air Removal Steam Sterilization. Each pack contains one 3M™ Attest™ Super Rapid Readout Biological Indicator 1492V.
Expand 1 Items
Rapid readout biological indicator 1295 for vaporised hydrogen peroxide sterilisation, Attest™
Supplier: 3M MEDICAL
3M™ Attest™ Rapid Readout Biological Indicators 1295 for vaporised hydrogen peroxide (VH2O2) sterilisation provide faster results.
Expand 1 Items
Spore strips, Attest™
Supplier: 3M MEDICAL
Biological indicators provide the best assurance of sterility by challenging the steriliser with quantifiable, highly resistant spores. After sterilisation, the vial is 'crushed' to join the growth media with the processed spore strip. A colour change to yellow indicates surviving spores and a positive result. Biological indicators are used for load control monitoring which is the process by which a load is monitored and released based on the result of a biological indicator (BI) in a test pack.
Expand 2 Items
Sterilisation indicators
Supplier: 3M MEDICAL
These chemical integrators are Class 5 integrating indicators used for pack control as a method for monitoring sterilisation process conditions inside each pack. They can also be used inside a process challenge device (PCD) to release processed items, excluding implants (load control), however they do not replace the use of biological indicators.
Expand 1 Items
Rapid readout biological indicator for ethylene oxide sterilisation, 1294, Attest™
Supplier: 3M MEDICAL
Rapid readout biological indicator for EO (ethylene oxide) sterilization.
Expand 1 Items
Sospensioni di spore, Sportrol™
Supplier: CROSSTEX
Sospensioni pure di spore vitali di microrganismi specifici caratterizzati da resistenza nota a diversi processi di sterilizzazione. Gli indicatori biologici sono utilizzati per verificare che le spore batteriche siano state completamente distrutte. L'indicatore è processato semplicemente insieme al carico nello sterilizzatore. L'assenza di crescita batterica dopo avere posto le spore in coltura indica che il processo di sterilizzazione è stato efficace. La crescita indica che la sterilizzazione non è stata efficace.
Expand 3 Items
Ethylene oxide chemical indicator strips 1251, Comply™
Supplier: 3M MEDICAL
The 3M™ Comply™ Steam Chemical Indicator 1251 is a paper strip 1,5 cm wide by 20 cm long printed with a chemical indicator ink that turns from red to green when exposed to the steam sterilisation process.
Expand 1 Items
Indicatori per sterilizzazione a vapore
Supplier: CROSSTEX
Gli indicatori chimici di sterilizzazione, non tossici virano dal blu al rosa dopo un'esposizione di 10 minuti a 121 °C o 2 minuti a 134 °C, in presenza di vapore saturo. Esposizioni più lunghe si traducono in una tonalità di rosa più brillante. La variazione del colore dal blu al rosa è sensibile al tempo, alla temperatura e alla presenza di vapore saturo.
Expand 1 Items
Self contained biological indicators (SCBI)
Supplier: CROSSTEX
Self-contained biological indicators (SCBIs) for monitoring steam sterilisation consist of a durable PC vial with cap, a crushable glass ampoule with Trypticase® soy broth (TSB) modified with pH indicator, and a disc inoculated with Geobacillus stearothermophilus spores.
Expand 2 Items
Mini spore discs
Supplier: CROSSTEX
Inoculated carrier mini spore discs for monitoring EO and dry heat processes.
Expand 1 Items
Sterilisation indicator tapes
Supplier: DELTALAB
Sterilisation indicator tapes for steam autoclave.
Expand 2 Items
Attest™ 390 Auto-Reader for Steam
Supplier: 3M MEDICAL
This auto-reader for steam, 390, is designed to incubate and automatically read the biological indicators for steam at 60 °C for a final fluorescent result.