Colonne cromatografiche
Le colonne cromatografiche separano le molecole all’interno delle miscele durante metodi a gas o liquido. Riempite con fasi stazionarie o resine, le opzioni preconfezionate riducono il tempo di preparazione richiesto. I pezzi verticali sono in grado di resistere a temperature estreme e fluttuazioni di pressione quando la fase mobile viene forzata attraverso il mezzo. Soddisfa le procedure di laboratorio preparative e analitiche con le colonne cromatografiche per separare componenti mobili dissimili in base a polarità, composizione e dimensione.
HPLC columns, LiChroCART®, LiChrospher® 100 DIOL
Supplier: Merck
Stainless steel LiChroCART® cartridges are available with LiChrospher® sorbents. Ideal for separation of compounds under basic eluents.
Expand 19 Items
Hibar® HPLC Columns, with Purospher® Sorbents
Supplier: Merck
Stainless steel Hibar® columns are complete with endfittings. These columns are available with various types of Purospher® sorbents.
Expand 52 Items
HPLC columns, LiChroCART®, Purospher® STAR RP-8e
Supplier: Merck
Stainless steel LiChroCART® cartridges are available with various types of Purospher® sorbents.
Expand 31 Items
HPLC columns, LiChroCART®, LiChrospher® 100 RP-18e
Supplier: Merck
Stainless steel LiChroCART® cartridges are available with LiChrospher® sorbents. Ideal for separation of compounds under basic eluents.
Expand 29 Items
HPLC columns, Hibar®, LiChrospher® 100 RP-8e
Supplier: Merck
Stainless steel Hibar® columns are complete with endfittings. These columns are available with various types of LiChrospher® sorbents.
Expand 8 Items
HPLC columns, SUPELCOSIL™, LC-NH₂, Supelco®
Supplier: Merck
Silica based SUPELCOSIL™ LC-NH₂ columns separate monosaccharides, disaccharides, and some trisaccharides, with elution generally in order of increasing molecular weight. Retention decreases as the proportion of water:acetonitrile in the mobile phase is increased.
Expand 9 Items
apHera™ HPLC Columns, Reversed Phase
Supplier: Merck
apHera™ reversed columns were developed specifically to provide the superior advantages of both silica and polystyrene columns, without the disadvantages of either. This was accomplished using a vinyl alcohol copolymer base that keeps the surface wetted even with high carbon loads. The porous structure has an average pore diameter large enough to produce ideal results for small analytes, peptides and small proteins.
Expand 6 Items
SPE tubes, Supelclean™ ENVI-18, Supelco®
Supplier: Merck
This Reversed phase Supelclean™ ENVI-18 are suitable for excellent for cleaning, extracting and concentrating pollutants from aqueous environmental sample (drinking, ground, waste water). Also suitable for extracting herbicides, fungicides and pesticides from waste material.
Expand 7 Items
Supelco® Ascentis® C8 HPLC Columns
Supplier: Merck
Ascentis® C8 HPLC columns are optimised to the three terms of the resolution equation: efficiency, retention, and selectivity.
Expand 11 Items
Supelco® Ascentis® Express Phenyl-Hexyl HPLC and UHPLC Columns
Supplier: Merck
Ascentis® Express 90 Å Phenyl-Hexyl high-speed, high-performance liquid chromatography columns are based on a Fused-Core® particle design.
Expand 52 Items
Supelco® Ascentis® Express ES-C18 HPLC and UHPLC Columns
Supplier: Merck
Ascentis® Express ES-C18 is a non-endcapped C18 stationary phase based on the proven Fused-Core® particle design.
Expand 23 Items
Discovery® RP-Amide C16 HPLC Columns
Supplier: Merck
The Discovery® RP-Amide C16 HPLC Column with unique retention and selectivity.
Expand 8 Items
Capillary columns, traditional phases, SPB-5, Supelco®
Supplier: Merck
These bonded poly(5% diphenyl/95% dimethylsiloxane) low phenyl content columns improve thermal stability of the phase, while still providing essentially a boiling point elution order, and a slight increase in selectivity, especially for aromatic compounds.
Expand 19 Items
Avantor® ACE® Excel® C18-AR, HPLC/UHPLC Columns, Analytical, 3 µm
Supplier: Avantor
The Avantor® ACE® Excel® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
Expand 21 Items
Avantor® ACE® Excel® C18-PFP, HPLC/UHPLC Columns, Analytical, 2 µm
Supplier: Avantor
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
Expand 17 Items
Avantor® ACE® Excel® C18-Amide, HPLC/UHPLC Columns, Analytical, 3 µm
Supplier: Avantor
Avantor® ACE® Excel® C18-Amide is a uniquely designed stationary phase offering improved retention of polar compounds, enhanced phenolic resolution and alternative selectivity to C18 bonded columns. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
Expand 19 Items
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.



