SPE Plate, 96-well, NBE TRACE-N20
Supplier: Tecan
An end-capped C18 silica sorbent ideal for reverse-phase retention of neutral and polar analytes.
Expand 1 Items
Atlas® SPE Plates, 96-well, RCH
Supplier: Tecan
A hydrophilic/lipophilic balanced chemistry offering selectivity to a wide range of analytes. It provides enhanced selectivity for polar species, also comes in larger particle for more viscous samples. A direct alternative to Waters Oasis® HLB and Phenomenex Strata X.
Expand 4 Items
Pesticide reference standard, Promecarb, PESTANAL®, analytical standard, Supelco®
Supplier: Merck
Promecarb may be used as a reference standard for the determination of promecarb in water by solid-phase extraction and liquid chromatography coupled with ionspray mass spectrometry.
Expand 1 Items
Atlas® RCH SCX SPE Plates, 96-well
Supplier: Tecan
A hydrophilic/lipophilic balanced strong cationic chemistry offering excellent selectivity to basic and neutral compounds. A direct alternative to waters Oasis® MCX and Phenomenex Strata XC.
Expand 2 Items
Atlas® NBE SPE Plates, 96-well
Supplier: Tecan
A hydrophilic/Lipophilic balanced chemistry offering selectivity to a wide range of analytes. It provides enhanced selectivity for polar species along with a unique NBE column platform. A direct alternative to Waters Oasis® HLB µElution.
Expand 2 Items
Organic reference standard, 4-Hydroxy-4-methyl-2-pentanone, analytical standard, Supelco®
Supplier: Merck
4-Hydroxy-4-methyl-2-pentanone may be used as an internal standard in the analysis of volatile odor-active compounds present in wine using solid phase extraction with gas chromatography (SPE-GC).
Expand 1 Items
Aluminium oxyde activé neutre Brockmann Grade I, Supelco®
Supplier: Merck
Brockmann aluminum oxides are suitable for column chromatography and adsorptive filtration. Aluminum oxides are generally used as solid support phases in solid phase extraction (SPE)-based clean-up procedures employed in chromatographic methods
Expand 2 Items
Cerex® RCH OFQC SPE Plate, 96-well
Supplier: Tecan
Proprieatary blend of ion-exchange and water-wettable polymer targeted towards oral fluid collection devices.
Expand 1 Items
Organic reference standard, Bisphenol E, analytical standard, Supelco®
Supplier: Merck
Bisphenol E may be used as a reference standard in the determination of bisphenol E in beverages using on-line solid-phase extraction with fast liquid chromatography coupled with tandem mass spectrometry (on-line SPE fast LC-MS/MS).
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Metrafenone
Supplier: Merck
Metrafenone CRM may also be used in the residue analysis of: 209 pesticides and persistent organic pollutants (POPs) extracted by QuEChERS-based procedure from fresh bovine and chicken liver samples using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). 379 pesticides in human serum samples extracted by QuEChERS method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Metrafenone in nine fresh vegetable samples using matrix solid-phase dispersion (MSPD) and HPLC-UV. Metrafenone in bitter gourd and soil samples using gas chromatography combined with an electron capture detector (GC-ECD).
Expand 1 Items
Vacuum manifolds, Visiprep
Supplier: Merck
Solid phase extraction vacuum manifolds allow to simultaneously process up to 12 or up to 24 SPE tubes. Precise flow control is provided through each SPE tube by rotating the independent, screw-type valves in the cover, this ensures the packing will not dry out in some tubes while others finish draining.
Expand 4 Items
Système d'extraction et équipement de séchage, LiChrolut®
Supplier: Merck
Toutes les étapes individuelles associées à l'extraction en phase solide peuvent être réalisées en utilisant le système d'extraction LiChrolut®. Ce système transparent et adapté au vide fabriqué en verre peut être utilisé pour préparer jusqu'à 12 échantillons simultanément.
Expand 3 Items
Positive pressure manifold, ASPEC®
Supplier: GILSON LCMS
The ASPEC® Positive pressure manifold uses positive pressure to improve reproducibility and recovery for solid phase extraction (SPE) applications.
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Monolinuron
Supplier: Merck
Monolinuron CRM may also be used as given below: Determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Extraction of 13 pesticides from four groundwater and three river water samples using silica-based MSU-1 mesoporous solid as a sorbent for their solid-phase extraction (SPE) followed by ultra-performance liquid chromatography-triple quadrupole-mass spectrometric (UHPLC- QqQ-MS/MS) determination. Development and validation of a UHPLC-diode array detection (DAD) method for simultaneous determination of urea and tebuthiuron herbicides in four fresh vegetable samples. Multi-residue analysis of 50 herbicides in 51 grain samples of soybean corn and wheat by ultra-performance liquid chromatography-electrospray ionisation-mass spectrometry (UPLC-ESI-MS). Extraction of 109 pesticide residues from different chemical classes from 345 tomato samples by modified QuEChERS method and their determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simultaneous analysis of 238 pesticides and 78 veterinary drugs in 80 bovine milk samples using ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).
Expand 1 Items
ASPEC® 241 system
Supplier: GILSON LCMS
This compact ASPEC® system combines positive pressure solid phase extraction (SPE) with small footprint and precise liquid handling for reliable automated SPE applications.
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Simazine
Supplier: Merck
Simazine CRM may also be used as given below: Development and validation of an ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME) method for sample extraction followed by gas chromatography-mass spectrometry based determination of endocrine-disrupting herbicides in the river and seawater samples. Determination of triazine pesticide residues in samples of apples pears carrots potatoes tomatoes avocado cucumber spinach bananas and oranges by modified QuEChERS and solid-phase extraction (SPE) procedures followed by liquid chromatography-photodiode array (LC-DAD) analysis. Multi-residue analysis of 67 pesticides in olive oil olives and avocado samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) to evaluate various clean-up sorbents. Quantitation of 20 pesticides in eel and shrimp samples by a scheduled multiple reaction monitoring (sMRM) method and QuEChERS with EDTA for sample extraction and purification. Analysis of 35 micropollutants including pesticides in water samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after their solid-phase extraction. Simultaneous quantification of 58 pharmaceuticals and personal care products (PPCPs) and pesticides in water samples by solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) combined with liquid chromatography-tandem mass spectrometry (LCMS/MS).
Expand 1 Items
Cartouches d'extraction en phase solide, LiChrolut®
Supplier: Merck
Les cartouches et accessoires LiChrolut® pour extraction en phase solide sont fabriqués selon des critères rigoureux. Toutes les cartouches pour extraction en phase solide (SPE) sont en polypropylène, sauf mention contraire. Elles sont compatibles avec tous les instruments automatisés et les robots pour extraction en phase solide. Trois critères essentiels sont soigneusement contrôlés.
Expand 8 Items
Supelco® TraceCERT® Organic Reference Standard, Tebutam
Supplier: Merck
Tebutam CRM may also be used as given below:
Optimisation of sample extraction based on QuEChERS and dispersive-solid-phase extraction (d-SPE) clean-up for the multi-residue analysis of 120 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls by liquid and gas chromatography coupled with tandem mass spectrometry (MS/MS)
Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)
Determination of 90 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls in honey samples by using QuEChERS combined with dispersive solid-phase extraction (SPME) for sample pre-treatment and liquid chromatography-triple-quadrupole tandem mass spectrometry and gas chromatography-ion-trap tandem mass spectrometry for quantitation
Screening and quantification of 569 pesticides in honeysuckle samples by a combination of ultrahigh-performance liquid chromatography (UHPLC) and quadrupole-Orbitrap high-resolution mass spectrometry
Simultaneous determination of 134 pesticide residues in tea samples using d-SPE extraction with a multi-functional filter (MFF) followed by ultra-high performance liquid chromatography (UPLC) and quadrupole time-of-flight mass spectrometry (TOF-MS).
Expand 1 Items
Micro-extraction en phase solide (MEPS™)
Supplier: Trajan Scientific and Medical
"Micro Extraction by Packed Sorbent" (MEPS™) est une technique développée pour la préparation d'échantillons par SPE (extraction en phase solide). Le produit MEPS™ se compose de deux parties, la seringue MEPS™ et le "Barrel Insert and Needle assembly" (BIN ensemble aiguille et piston). La technique MEPS™ pour préparer l'échantillon est utilisable en mode direct, mode phase inverse, en mode mixte et en échange d'ions. Comme les MEPS™ BIN peuvent s'utiliser pour des petits volumes jusqu'à 10 µl, ils représentent un outil performant pour l'usage en ligne d'analyses LC-MS de volumes réduits.
Expand 7 Items
Hazardous Waste Filtration System
Supplier: Merck
If your waste samples contain non-volatile or semi-volatile substances or metals, use this hazardous waste filtration system for saparation, extratction, and filtration. Developed in collaboration with the US Environmental Protection Agency (EPA), the system is designed specifically for the US EPA Extraction Procedure (EP) Toxicity Test and Toxicity Characteristic Leaching Procedure (TCLP). The device separates solid and liquid phases of waste samples for analysis.
Expand 3 Items
ASPEC® 274 system
Supplier: GILSON LCMS
This ASPEC® system for positive pressure solid phase extraction (SPE) automation maximises throughput by processing up to four samples in parallel. With its small footprint and multiple probes, it is the ideal choice for reproducible and efficient sample cleanup for clinical, forensic, doping, food, and environmental testing labs.
Expand 1 Items
Cerex® FLORASIL SPE Columns
Supplier: Tecan
Florisil is used for sample preparation (solid phase extraction) of e.g., organic tin compounds and aliphatic carboxylic acids. Florisil is a magnesium silicate.
Expand 1 Items
Colonnes SPE, à base de polymères, J.T.Baker®, BAKERBOND spe™ SDB
Supplier: Avantor
En tant que technique de préparation des échantillons, l’extraction en phase solide nécessite souvent une bonne stabilité des phases stationnaires dans toute la plage de pH. L'absorbant en copolymère de styrène-divinylbenzène (SDB) peuvent améliorer la qualité de la préparation des échantillons.
Expand 11 Items
Supelco® TraceCERT® Organic Reference Standard, Tebufenpyrad
Supplier: Merck
Profenofos CRM may also be used as given below: Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. Gas chromatography-tandem mass spectrometry (GC-MS/MS) based analysis of 213 pesticide residues in soybean after their extraction by QuEChERS procedure. Detection of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Multi-residue analysis of 160 multiclass pesticides using ethyl acetate (EtAC)/n. hexane mixture for extraction from chamomile thyme and marjoram samples and their analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). Simultaneous determination of 34 pesticides in various environmental water samples by dispersive liquid-liquid microextraction (DLLME) technique in combination with gas chromatography-mass spectrometry(GC-MS/MS). Quantitation of 40 multi-class insecticides and fungicides in 81 apple samples by using gas- and liquid- chromatography-mass following a QuEChERS-based extraction.
Expand 1 Items
C18 EWP plates, Bond Elut
Supplier: VARIAN
Bond Elut C18 EWP uses a special silica with wide pores. This is endcapped.
Expand 2 Items
SPEC 96-well plates
Supplier: VARIAN
Solid Phase Extraction (SPE) plate, SPEC 96-well plate, Silica-based sorbents, 30 mg
Expand 13 Items
SPE Plates, 96-Well, Hypersep™ Hypercarb
Supplier: Thermo Fisher Scientific
Solid Phase Extraction (SPE) plate, HyperSep™, Hypercarb™, 50 mg, 1 ml
Expand 3 Items
SI plates, Bond Elut™
Supplier: VARIAN
Native silica is generally regarded as the most polar SPE sorbent available. Bond Elut SI is particularly effective at separating compounds with a very similar structure.
Expand 2 Items
Colonnes SPE pour applications spéciales, J.T.Baker®, BAKERBOND spe™ PCB-N
Supplier: Avantor
Cette colonne pour extraction en phase solide a été conçue pour l’extraction des PCB dans l’huile.
Expand 1 Items
96-well plates, Bond Elut™ Plexa™ PAX
Supplier: VARIAN
Solid Phase Extraction (SPE) plate, Bond Elut™ Plexa™ PAX, 30 mg, 30 mg