Discovery® C8 HPLC Columns

Discovery® C8 HPLC Columns

Supplier:   Merck
Discovery® C8 HPLC Columns
Supplier:  Merck
Certificates

9 Options Available Below

Product Details & Documents

The Discovery® C8 columns provide the best suitable selectivity for many applications.

  • Less hydrophobic reversed-phase selectivity
  • Retention with excellent peak shape for all compounds
  • Very high stability and no-bleeding properties for LC-MS application
  • Impurity: <10 ppm metals
  • Surface coverage: 3,4 µmol/m²

Designed to meet the exacting requirements of pharmaceutical analysis and purification. Discovery® columns are also ideal for all application segments requiring reversed phase HPLC.

Ordering information: Column test certificate available inside the box.

Specifications for Product Family

Specifications

  • Catalog No:
  • 577501-U
  • 59353-U21
  • 569426-U
  • 59352-U
  • 569427-U
  • 59353-U
  • 59354-U
  • 59588-U
  • 59589-U
  • Application:
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Small molecule separation, Food and beverage, HPLC and LC/MS suitable
  • Charge de carbone:
  • 8%
  • 8%
  • 8%
  • 8%
  • 8%
  • 8%
  • 8%
  • 8%
  • 8%
  • End-capping:
  • Oui
  • Oui
  • Oui
  • Oui
  • Oui
  • Oui
  • Oui
  • Oui
  • Oui
  • Pression max.:
  • 400 bar
  • 400 bar
  • 400 bar
  • 400 bar
  • 400 bar
  • 400 bar
  • 400 bar
  • 400 bar
  • 400 bar
  • Plage de pH:
  • 2 - 8
  • 2 - 8
  • 2 - 8
  • 2 - 8
  • 2 - 8
  • 2 - 8
  • 2 - 8
  • 2 - 8
  • 2 - 8
  • Surface area:
  • 200 m²/g
  • 200 m²/g
  • 200 m²/g
  • 200 m²/g
  • 200 m²/g
  • 200 m²/g
  • 200 m²/g
  • 200 m²/g
  • 200 m²/g
  • Temperature limit:
  • ≤70 °C
  • ≤70 °C
  • ≤70 °C
  • ≤70 °C
  • ≤70 °C
  • ≤70 °C
  • ≤70 °C
  • ≤70 °C
  • ≤70 °C
  • Code USP:
  • L7
  • L7
  • L7
  • L7
  • L7
  • L7
  • L7
  • L7
  • L7
  • Conditions de transport:
  • 100% methanol
  • 100% methanol
  • 100% methanol
  • 100% methanol
  • 100% methanol
  • 100% methanol
  • 100% methanol
  • 100% methanol
  • 100% methanol

Specifications

Product Family Options

Analytical columns, 5 µm

Product Information

  • Désignation
    Type de colonne
    Greffage
    Matériau de colonne
    Taille de pore
    Granulométrie
    Ø int.
    Longueur
    Availability
    Price
  • C8 HPLC columns
    Analytique
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    2,1 mm
    20 mm
    Log in for availability
    Log in for availability
    1 * 1 Un.
    1 * 1 Un.

    Specifications:
    More
    Specifications
    Cat. No.
    577501-U
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7
    Conditions de transport
    100% methanol
  • C8 HPLC columns
    Analytique
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    2,1 mm
    150 mm
    Log in for availability
    Log in for availability
    1 * 1 Un.
    1 * 1 Un. - SFr. 814.00
    SFr. 814.00
    1 * 1 Un.
       SFr. 814.00

    Specifications:
    More
    Specifications
    Cat. No.
    59353-U21
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7
    Conditions de transport
    100% methanol
  • C8 HPLC columns
    Analytique
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    4,0 mm
    125 mm
    Log in for availability
    Log in for availability
    1 * 1 Un.
    1 * 1 Un. - SFr. 740.00
    SFr. 740.00
    1 * 1 Un.
       SFr. 740.00

    Specifications:
    More
    Specifications
    Cat. No.
    569426-U
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7
    Conditions de transport
    100% methanol
  • C8 HPLC columns
    Analytique
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    4,6 mm
    50 mm
    Log in for availability
    Log in for availability
    1 * 1 Un.
    1 * 1 Un. - SFr. 524.00
    SFr. 524.00
    1 * 1 Un.
       SFr. 524.00

    Specifications:
    More
    Specifications
    Cat. No.
    59352-U
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7
    Conditions de transport
    100% methanol
  • C8 HPLC columns
    Analytique
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    4,6 mm
    125 mm
    Log in for availability
    Log in for availability
    1 * 1 Un.
    1 * 1 Un. - SFr. 740.00
    SFr. 740.00
    1 * 1 Un.
       SFr. 740.00

    Specifications:
    More
    Specifications
    Cat. No.
    569427-U
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7
    Conditions de transport
    100% methanol
  • C8 HPLC columns
    Analytique
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    4,6 mm
    150 mm
    Log in for availability
    Log in for availability
    1 * 1 Un.
    1 * 1 Un. - SFr. 814.00
    SFr. 814.00
    1 * 1 Un.
       SFr. 814.00

    Specifications:
    More
    Specifications
    Cat. No.
    59353-U
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7
    Conditions de transport
    100% methanol
  • C8 HPLC columns
    Analytique
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    4,6 mm
    250 mm
    Log in for availability
    Log in for availability
    1 * 1 ST
    1 * 1 ST - SFr. 888.00
    SFr. 888.00
    1 * 1 ST
       SFr. 888.00

    Specifications:
    More
    Specifications
    Cat. No.
    59354-U
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7
    Conditions de transport
    100% methanol

Supelguard™ guard cartridge, 5 µm

Product Information

  • Désignation
    Type de colonne
    Greffage
    Matériau de colonne
    Taille de pore
    Granulométrie
    Ø int.
    Longueur
    Availability
    Price
  • C8 HPLC columns (2 guard cartridges)
    Cartouche de garde
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    2,1 mm
    20 mm
    Log in for availability
    Log in for availability
    1 * 1 Un.
    1 * 1 Un. - SFr. 271.00
    SFr. 271.00
    1 * 1 Un.
       SFr. 271.00

    Specifications:
    More
    Specifications
    Cat. No.
    59588-U
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7
    Conditions de transport
    100% methanol

Supelguard™ guard kit, 5 µm

Product Information

  • Désignation
    Type de colonne
    Greffage
    Matériau de colonne
    Taille de pore
    Granulométrie
    Ø int.
    Longueur
    Availability
    Price
  • C8 HPLC columns (Kit: guard cartridge, stand-alone holder, tubing, 2 nuts and ferrules)
    Cartouche de garde
    C8 (Octyl), RP-Amide
    Acier inoxydable
    180 Å
    5 µm
    4,0 mm
    20 mm
    Log in for availability
    Log in for availability
    1 * 1 ST
    1 * 1 ST - SFr. 275.00
    SFr. 275.00
    1 * 1 ST
       SFr. 275.00

    Specifications:
    More
    Specifications
    Cat. No.
    59589-U
    Application
    Small molecule separation, Food and beverage, HPLC and LC/MS suitable
    Charge de carbone
    8%
    End-capping
    Oui
    Pression max.
    400 bar
    Plage de pH
    2 - 8
    Surface area
    200 m²/g
    Temperature limit
    ≤70 °C
    Code USP
    L7