Saisie de commande
Switzerland
Lien pour commandesContactUsLinkComponent
Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216

Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216

Fournisseur:   Thermo Orion
Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216
Fournisseur:  Thermo Orion
Certificats
Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216

2 variantes

Product Details & Documents

This benchtop meter is ideal for a wide range of applications and advanced pH and dissolved oxygen analysis in the lab. It offers two measuring channels allowing users to measure pH and dissolved oxygen simultaneously or view each channel separately. Can be used with RDO optical or polarographic DO probes.

  • Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
  • Measurement stability indicator and selectable read modes - Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
  • Data log collects and date/time stamps up to 2000 measurement sets with optional sample ID and user ID
  • Calibration log stores ten most recent calibrations
  • Non volatile meter memory ensures your data and settings are protected, even with loss of power
  • Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
  • Flexible power options with universal power adapter or optional AA batteries
  • Three year meter warranty

IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.

Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two.

Perform up to a five point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values and calibration editing option that allows individual points to be fixed without a full recalibration. Calibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options.

Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings.

Informations de livraison: Supplied with electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate.
The kit additionally includes: 8157BNUMD ROSS Ultra Triode refillable epoxy-body pH/ATC electrode, 083005MD Polarographic DO sensor with calibration sleeve, ROSS pH buffer and storage solution kit, DO sensor maintenance kit and BOD adapter, funnel and stirrer.

Spécifications de la famille de produits

Spécifications

  • Catalog No:
  • 665-0273
  • 665-0274
  • Modèle:
  • A216
  • A216
  • pH - Gamme:
  • –2,000...+20,000
  • –2,000...+20,000
  • pH - Résolution:
  • 0,1/0,01/0,001
  • 0,1/0,01/0,001
  • Précision - pH:
  • ±0,002
  • ±0,002
  • pH - Étalonnage:
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • mV - Gamme:
  • ±2000,0
  • ±2000,0
  • mV - Résolution:
  • 0,1
  • 0,1
  • mV - Précision:
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • OD Concentration:
  • 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
  • 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
  • Oxygène dissous - Résolution:
  • 0,1/0,01 mg/L
  • 0,1/0,01 mg/L
  • Oxygène dissous - saturation:
  • 0 - 600% (polarographic); 0 - 500% (RDO)
  • 0 - 600% (polarographic); 0 - 500% (RDO)
  • OD Précision:
  • Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
  • Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
  • OD Etalonnage:
  • Water-saturated air, air saturated water, manual (Winkler) and zero point
  • Water-saturated air, air saturated water, manual (Winkler) and zero point
  • Oxygène dissous - Gamme de pression barométrique:
  • Automatic or manual, 450 - 850 mm Hg
  • Automatic or manual, 450 - 850 mm Hg
  • DO range:
  • 0,00 - 90,00 mg/L
  • 0,00 - 90,00 mg/L
  • Gamme de température:
  • –5,0...+50,0 °C
  • –5,0...+50,0 °C
  • Détermination dela température:
  • 0,1 °C
  • 0,1 °C
  • Exactitude de la températue:
  • ±0,1 °C
  • ±0,1 °C
  • Compensation de température:
  • Automatic or manual
  • Automatic or manual
  • Gamme de pression:
  • 400 - 850 mm Hg
  • 400 - 850 mm Hg
  • Affichage:
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Type de batterie:
  • 4 AA (sold separately)
  • 4 AA (sold separately)
  • Batterie - Durée de vie:
  • 800 h
  • 800 h
  • Alimentation:
  • AC adapter (included) or 4 AA batteries
  • AC adapter (included) or 4 AA batteries
  • Conformités:
  • CE, TUV 3-1, FCC Class A
  • CE, TUV 3-1, FCC Class A
  • Température de service:
  • 5...45 °C (ambient)
  • 5...45 °C (ambient)
  • Acquisition des données - Enregistrement:
  • Manual/Automatic with AUTO-READ™
  • Manual/Automatic with AUTO-READ™
  • Acquisition des données - Capacité:
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • Mémoire:
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Langues:
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • Indice IP:
  • IP 54
  • IP 54
  • Connexions:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • Sorties:
  • RS232, USB
  • RS232, USB
  • Entrée:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • Alarme:
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • Nombre de canaux:
  • 2
  • 2
  • Étalonnage:
  • pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
  • pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
  • Points d’étalonnage:
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • L×P×H:
  • 240×180×110 mm
  • 240×180×110 mm
  • Poids:
  • 0,9 kg
  • 0,9 kg

Spécifications

Product Family Options

Informations sur le produit

  • Désignation
    Disponibilité
    Prix
  • Bench pH/DO meter Orion Star A216, instrument alone
    Connexion Pour la disponibilité
    Connexion Pour la disponibilité
    1 * 1 ST
    1 * 1 ST - SFr. 1’990.00
    SFr. 1’990.00
    1 * 1 ST
       SFr. 1’990.00

    Spécifications :
    Plus
    Specifications
    Cat. No.
    665-0273
    Modèle
    A216
    pH - Gamme
    –2,000...+20,000
    pH - Résolution
    0,1/0,01/0,001
    Précision - pH
    ±0,002
    pH - Étalonnage
    Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
    mV - Gamme
    ±2000,0
    mV - Résolution
    0,1
    mV - Précision
    ±0,2 mV or ±0,05% of reading, whichever is greater
    OD Concentration
    0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
    Oxygène dissous - Résolution
    0,1/0,01 mg/L
    Oxygène dissous - saturation
    0 - 600% (polarographic); 0 - 500% (RDO)
    OD Précision
    Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
    OD Etalonnage
    Water-saturated air, air saturated water, manual (Winkler) and zero point
    Oxygène dissous - Gamme de pression barométrique
    Automatic or manual, 450 - 850 mm Hg
    DO range
    0,00 - 90,00 mg/L
    Gamme de température
    –5,0...+50,0 °C
    Détermination dela température
    0,1 °C
    Exactitude de la températue
    ±0,1 °C
    Compensation de température
    Automatic or manual
    Gamme de pression
    400 - 850 mm Hg
    Affichage
    Graphic LCD with backlight
    Type de batterie
    4 AA (sold separately)
    Batterie - Durée de vie
    800 h
    Alimentation
    AC adapter (included) or 4 AA batteries
    Conformités
    CE, TUV 3-1, FCC Class A
    Température de service
    5...45 °C (ambient)
    Acquisition des données - Enregistrement
    Manual/Automatic with AUTO-READ™
    Acquisition des données - Capacité
    2000 with date and time stamp
    Mémoire
    Non-volatile memory preserves data log, calibration log and meter settings
    Langues
    English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
    Indice IP
    IP 54
    Connexions
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Sorties
    RS232, USB
    Entrée
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Alarme
    High/low limit alarm, calibration due alarm
    Nombre de canaux
    2
    Étalonnage
    pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
    Points d’étalonnage
    1 point relative mV (RmV) mode, 1 point ORP mode
    L×P×H
    240×180×110 mm
    Poids
    0,9 kg
  • Bench pH/DO meter Orion Star A216, kit incl. ROSS Ultra Triode pH/ATC probe and polarographic DO probe
    Connexion Pour la disponibilité
    Connexion Pour la disponibilité
    1 * 1 ST
    1 * 1 ST - SFr. 3’240.00
    SFr. 3’240.00
    1 * 1 ST
       SFr. 3’240.00

    Spécifications :
    Plus
    Specifications
    Cat. No.
    665-0274
    Modèle
    A216
    pH - Gamme
    –2,000...+20,000
    pH - Résolution
    0,1/0,01/0,001
    Précision - pH
    ±0,002
    pH - Étalonnage
    Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
    mV - Gamme
    ±2000,0
    mV - Résolution
    0,1
    mV - Précision
    ±0,2 mV or ±0,05% of reading, whichever is greater
    OD Concentration
    0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
    Oxygène dissous - Résolution
    0,1/0,01 mg/L
    Oxygène dissous - saturation
    0 - 600% (polarographic); 0 - 500% (RDO)
    OD Précision
    Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
    OD Etalonnage
    Water-saturated air, air saturated water, manual (Winkler) and zero point
    Oxygène dissous - Gamme de pression barométrique
    Automatic or manual, 450 - 850 mm Hg
    DO range
    0,00 - 90,00 mg/L
    Gamme de température
    –5,0...+50,0 °C
    Détermination dela température
    0,1 °C
    Exactitude de la températue
    ±0,1 °C
    Compensation de température
    Automatic or manual
    Gamme de pression
    400 - 850 mm Hg
    Affichage
    Graphic LCD with backlight
    Type de batterie
    4 AA (sold separately)
    Batterie - Durée de vie
    800 h
    Alimentation
    AC adapter (included) or 4 AA batteries
    Conformités
    CE, TUV 3-1, FCC Class A
    Température de service
    5...45 °C (ambient)
    Acquisition des données - Enregistrement
    Manual/Automatic with AUTO-READ™
    Acquisition des données - Capacité
    2000 with date and time stamp
    Mémoire
    Non-volatile memory preserves data log, calibration log and meter settings
    Langues
    English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
    Indice IP
    IP 54
    Connexions
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Sorties
    RS232, USB
    Entrée
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Alarme
    High/low limit alarm, calibration due alarm
    Nombre de canaux
    2
    Étalonnage
    pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
    Points d’étalonnage
    1 point relative mV (RmV) mode, 1 point ORP mode
    L×P×H
    240×180×110 mm
    Poids
    0,9 kg
Accessories

Informations sur le produit

  • N° de catalogue
    Désignation
    Pour
    Disponibilité
    Prix
  • ORIOSTARA-BEA
    Support d'électrode relié à un appareil de mesure pour paillasse (bras et tête de support d'électrode), Orion™ Star A, mouvement à 360° (sans base lestée)
    Appareils de mesure pour paillasse Orion Star A110 + A210, Orion Versa Star
    Connexion Pour la disponibilité
    1 * 1 ST - SFr. 202.00

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • 662-1140
    Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cable
    Connexion Pour la disponibilité
    1 * 1 SET - SFr. 94.40

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • 662-1547
    Adaptateur universel supplémentaire de rechange pour appareils de mesure de paillasse et portables Thermo Scientific™ Orion™ Star A et appareils de mesure hérités Orion™ Star et Star Plus
    Connexion Pour la disponibilité
    1 * 1 ST - SFr. 89.50

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • ORIOSTARA-HB
    Base lestée Orion™ Star™ A pour utilisation avec un support d'électrode relié à l'appareil de mesure
    Connexion Pour la disponibilité
    1 * 1 ST - SFr. 69.60

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • ORIO1010053
    Câble RS232, pour raccorder un appareil de mesure à un PC ou une imprimante
    Connexion Pour la disponibilité
    1 * 1 ST - SFr. 56.10

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • ORIO1010005
    Adaptateur de câble, pour raccorder le port RS232 d'un appareil de mesure à un port USB
    Connexion Pour la disponibilité