Specifications

  • Catalog No:
  • ORIOVSTAR50
  • 662-2496
  • Modèle:
  • Orion™ Versa Star Pro™, with pH and conductivity module
  • Orion™ Versa Star Pro™, with pH and conductivity module
  • pH - Gamme:
  • −2,000...+20,000
  • −2,000...+20,000
  • pH - Résolution:
  • 0,1/0,01/0,001
  • 0,1/0,01/0,001
  • Précision - pH:
  • ±0,002
  • ±0,002
  • pH - Étalonnage:
  • Up to 6 points
  • Up to 6 points
  • mV - Gamme:
  • ±2000,0
  • ±2000,0
  • mV - Résolution:
  • 0,1
  • 0,1
  • mV - Précision:
  • ±0,2 or 0,05% of reading (whichever is greater)
  • ±0,2 or 0,05% of reading (whichever is greater)
  • Plage de conductivité:
  • 0,001 µS/cm - 3000 mS/cm
  • 0,001 µS/cm - 3000 mS/cm
  • Résolution de conductivité:
  • 0,001 μS minimum, auto ranging up to 4 significant digits
  • 0,001 μS minimum, auto ranging up to 4 significant digits
  • Précision de la conductivité:
  • 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
  • 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
  • Constante de cellule de conductivité:
  • 0,001 - 199,9 cm⁻¹
  • 0,001 - 199,9 cm⁻¹
  • Étalonnage de conductivité:
  • Up to 6 points
  • Up to 6 points
  • Salinité - Gamme:
  • 0,06 - 80,00 psu / 0,05 - 42,00 ppt
  • 0,06 - 80,00 psu / 0,05 - 42,00 ppt
  • Salinité - Résolution:
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • Salinité - Précision:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • TDS - Gamme:
  • 0,001 - 200,0 ppm
  • 0,001 - 200,0 ppm
  • TDS - Résolution:
  • 0,001 ppm minimum, auto ranging up to 4 significant digits
  • 0,001 ppm minimum, auto ranging up to 4 significant digits
  • TDS - Précision:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • TDS - Facteur de conversion:
  • Linear (0,02 - 9,99)
  • Linear (0,02 - 9,99)
  • Gamme de température:
  • −5,0...+105,0 °C
  • −5,0...+105,0 °C
  • Détermination dela température:
  • 0,1 °C
  • 0,1 °C
  • Exactitude de la températue:
  • ±0,1 °C
  • ±0,1 °C
  • Calibrage de température:
  • 1 point temperature offset calibration, 3 point LogR temperature calibration
  • 1 point temperature offset calibration, 3 point LogR temperature calibration
  • Compensation de température:
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Affichage:
  • Colour graphic LCD with backlight
  • Colour graphic LCD with backlight
  • Conformités:
  • IP 54
  • IP 54
  • Température de service:
  • 5...45 °C
  • 5...45 °C
  • Acquisition des données - Enregistrement:
  • Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
  • Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
  • Acquisition des données - Capacité:
  • 2000 points
  • 2000 points
  • Connexions:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe)
  • Sorties:
  • RS232, USB (2)
  • RS232, USB (2)
  • L×P×H:
  • 280×240×100 mm
  • 280×240×100 mm
  • Poids:
  • 1,2 kg (modules add 0,2 kg each)
  • 1,2 kg (modules add 0,2 kg each)