Water testing kit, MINIKIT
À propos de cet article
MINIKIT provides quick and simple tests for the analysis of boiler water, cooling water, drinking and industrial water.
- MINIKITS are based on titrimetric methods
- Easy operation and exact reagent dosing
- Foil-wrapped tablet reagents with a minimum guaranteed shelf life of five years
Tablet count method: In this method the liquid titration solution and indicator are replaced by AQUALYTIC® tablet reagents. A specific number of tablets is added to a defined sample volume until a chemically induced colour change takes place. The concentration of the parameter being measured is calculated from the number of tablets required. The measuring range can be expanded by varying the sample volume.
Yes/No test: This method tells whether a specific ingredient is present in the water and/or if its concentration is higher or lower than a defined level.
Turbidity method: A two-section calibrated test tube is filled with the water sample and a reagent tablet added. The reagent creates a level of turbidity that is proportional to the concentration of the parameter being measured. The inner tube, which has a black dot on its base, is lowered until the dot is obscured by the turbidity. The result is read off from the water level in the inner tube.
19 variantes
Product Details & Documents
MINIKIT provides quick and simple tests for the analysis of boiler water, cooling water, drinking and industrial water.
- MINIKITS are based on titrimetric methods
- Easy operation and exact reagent dosing
- Foil-wrapped tablet reagents with a minimum guaranteed shelf life of five years
Tablet count method: In this method the liquid titration solution and indicator are replaced by AQUALYTIC® tablet reagents. A specific number of tablets is added to a defined sample volume until a chemically induced colour change takes place. The concentration of the parameter being measured is calculated from the number of tablets required. The measuring range can be expanded by varying the sample volume.
Yes/No test: This method tells whether a specific ingredient is present in the water and/or if its concentration is higher or lower than a defined level.
Turbidity method: A two-section calibrated test tube is filled with the water sample and a reagent tablet added. The reagent creates a level of turbidity that is proportional to the concentration of the parameter being measured. The inner tube, which has a black dot on its base, is lowered until the dot is obscured by the turbidity. The result is read off from the water level in the inner tube.
Documents
Certificats
Rechercher par numéro de lotSpécifications de la famille de produits
Spécifications
Product Family Options
Tablet count method
Informations sur le produit
- DésignationPlage de mesureTypeCdtDisponibilitéPrix
- Cleaning Acid Strength0,75 - 10 % acidAF 4101 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.LOVI414100 - Organo-Phosphonate1 - 20 mg/l active O-PAF 4111 KITConnexion Pour la disponibilité1 * 1 KITSFr. 267.00Spécifications :
Plus
Specifications
Cat. No.LOVI414110 - Alkalinity, Total (M)10 - 500 mg/l CaCO3, ~0,1 - 5 mmol/lAF 4131 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.705-0410 - Spécifications :
Plus
Specifications
Cat. No.705-0411 - Alkalinity Caustic/P20 - 500 mg/l CaCO3AF 4151 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.705-0413 - Calcium Hardness10 - 500 mg/l CaCO3, ~ 0,1 - 5 mmol/lAF 4161 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.705-0414 - Spécifications :
Plus
Specifications
Cat. No.705-0415 - Hardness Total5 - 500 mg/l CaCO3, ~ 0,05 - 5 mmol/lAF 4241 KITConnexion Pour la disponibilité1 * 1 KITSFr. 88.80Spécifications :
Plus
Specifications
Cat. No.LOVI414240 - Hardness Total (low range)1 - 50 mg/l CaCO3, ~ 0,01 - 0,5 mmol/lAF 4251 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.LOVI414250 - Hardness Total (very low range)1 - 10 mg/l CaCO3, ~ 0,01 - 0,1 mmol/lAF 4261 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.LOVI414260 - Spécifications :
Plus
Specifications
Cat. No.705-0417 - Sulphate (low range)20 - 200 mg/l Na2SO4AF 4321 KITConnexion Pour la disponibilité1 * 1 KITSFr. 126.00Spécifications :
Plus
Specifications
Cat. No.LOVI414320 - Sulphite (low range)2 - 50 mg/l Na2SO3AF 4341 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.LOVI414340 - Sulphite (high range)20 - 500 mg/l Na2SO3AF 4351 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.705-0421 - Spécifications :
Plus
Specifications
Cat. No.705-0422
Yes/No test method
Informations sur le produit
- DésignationPlage de mesureTypeCdtDisponibilitéPrix
- QAC (Quaternary Ammonium Comp.)0 - 500 mg/l active QAC Limit 200 mg/l (Yes/No)AF 4171 KITConnexion Pour la disponibilité1 * 1 KITSFr. 116.00Spécifications :
Plus
Specifications
Cat. No.705-0420 - Hardness Total (Yes/No)Limit 4 mg/l, 8 mg/l or 20 mg/l CaCO3, ~ 0,04 or 0,08 or 0,2 mmol/lAF 4231 KITConnexion Pour la disponibilité1 * 1 KITSFr. 91.60Spécifications :
Plus
Specifications
Cat. No.LOVI414230
Turbidity test method
Informations sur le produit
- DésignationPlage de mesureTypeCdtDisponibilitéPrix
- Spécifications :
Plus
Specifications
Cat. No.LOVI414220 - Sulphate40 - 200 mg/l SO4 (40 - 4000 mg/l by dilution)AF 4311 KITConnexion Pour la disponibilité1 * 1 KITSFr. 126.00Spécifications :
Plus
Specifications
Cat. No.LOVI414310
Accessories
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
- LOVI385130Dilution/shaker tube with lid, plastic, graduated, 100 mlConnexion Pour la disponibilité1 * 1 ST - SFr. 14.20
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
- LOVI385132Dilution/shaker tube with lid, plastic, graduated, 30 mlConnexion Pour la disponibilité1 * 1 ST - SFr. 14.20