PCR tests detect if even low levels of organisms are present. Pathogens that are ordinarily difficult to locate within culture samples are demonstrated with the simple polymerase chain reaction supplies. Working more rapidly than culturing procedures, researchers can achieve more accurate results before time impacts the overall viability. With the complete supplies required, the automated PCR tests identify microbes or bacteria within samples that pose a threat.
qPCR detection kits for gastrointestinal infections, Genesig®
Supplier: PRIMERDESIGN
PCR kits for the detection and simultaneous quantification of gastrointestinal pathogens.
Expand 27 Items
Real Time PCR Detetction Test Kit Gluten
Supplier: BIOPREMIER
Gluten detection test kit by using qPCR. Celiac disease is an autoimmune disorder associated with an intolerance to gluten proteins mainly present in wheat, barley, and rye.
Expand 1 Items
Real-Time PCR detection kits, Allergen
Supplier: BIOPREMIER
These kits allow the detection of allergic substances. Ideal for controlling and monitoring the various steps of food production.
Expand 22 Items
Real Time PCR Detetction Test Kits, SUPREME
Supplier: BIOPREMIER
SUPREME Real time detection uses real-time PCR for the detection of DNA present in the mitochondrial genome in a simple, reliable, and rapid procedure. The assay is based on 5’ nuclease real time PCR reactions to amplify a unique genomic sequence in the target.
Expand 28 Items
qPCR detection kits for hepatitis virus, genesig®
Supplier: PRIMERDESIGN
PCR kits for the detection and simultaneous quantification of hepatitis viruses.
Expand 5 Items
qPCR detection kits for herpes infections, genesig®
Supplier: PRIMERDESIGN
PCR kits for the detection and simultaneous quantification of human herpes viruses.
Expand 11 Items
Real-Time PCR kit for detection of mycoplasma, Microsart® RESEARCH Mycoplasma
Supplier: Sartorius
The Microsart® RESEARCH Mycoplasma real-time PCR kit is especially designed for fast and reliable Mycoplasma contamination control in cell cultures, cell culture supernatants and media most applicable in research and development, e.g. biotech and biopharmaceutical research and development, universities and governmental research groups or for in-process control during biopharmaceutical production processes.
Expand 2 Items
Real-Time PCR kit for detection of mycoplasma, Microsart® ATMP Mycoplasma
Supplier: Sartorius
The Microsart® ATMP Mycoplasma detection kit is especially designed for an easy and fast detection of mycoplasma in cell-based therapeutics like autologous chondrocyte transplants (ATMPs –advanced therapy medical products). Due to the short shelf life of these therapeutics, a fast result is needed. The PCR-technology makes it possible to reduce the time-to-result to only 3 hours.
Expand 1 Items
qPCR detection kits for Human Papillomaviruses (HPV), Genesig®
Supplier: PRIMERDESIGN
Papillomaviruses are a diverse group of DNA-based viruses that infect the skin and mucous membranes of humans and a variety of animals. Although more than 100 different human papillomavirus (HPV) types have been characterised HPV 6, HPV 11, HPV-16 and HPV 18 are the most clinically relevant.
Expand 9 Items
Coffrets de test pour l'identification de micro-organismes pathogènes
Supplier: BIOPREMIER
Les coffrets de test pour la sécurité alimentaire offrent une procédure simple, fiable et rapide pour détecter la présence de bactéries pathogènes spécifiques. Le dosage repose sur des réactions PCR en temps réel utilisant une nucléase marquée en 5' pour amplifier une séquence génomique unique dans l'organisme cible. La PCR est une méthode utilisée pour amplifier une séquence d'ADN spécifique qui est généralement amplifiée dans une réaction contenant une ADN polymérase thermostable, des nucléotides et des amorces complémentaires de la séquence cible. Lorsque cette solution est chauffée, la molécule d'ADN se dénature et se sépare en deux brins. À mesure que la solution refroidit, les amorces se fixent aux séquences cibles par annelage dans les brins d'ADN séparés, et la polymérase d'ADN synthétise un nouveau brin en étendant les amorces à l'aide de nucléotides, créant ainsi une copie de la séquence d'ADN (amplicons). Lorsqu'il est répété, ce cycle de dénaturation, de recuisson et d'extension augmente de façon exponentielle le nombre d'amplicons cibles. Dans la PCR en temps réel, les sondes fluorescentes spécifiques sont utilisées pour détecter l'ADN amplifié par hybridation avec les amplicons. Ces sondes sont liées à un fluorophore à une extrémité et à un suppresseur (quencher) qui supprime la fluorescence à une autre. Si la séquence cible est présente pendant la PCR, une amplification se produit et la sonde est dégradée, provoquant ainsi une augmentation de la fluorescence. La fluorescence est mesurée par un détecteur et le logiciel associé trace l'intensité de la fluorescence par rapport au nombre de cycles, permettant ainsi de déterminer la présence ou l'absence de l'organisme cible.
Expand 12 Items
Kits de sécurité alimentaire pour la détection d'espèces animales dans les produits à base de viande
Supplier: BIOPREMIER
Les kits de sécurité alimentaire constituent une procédure simple, fiable et rapide pour détecter la présence d'espèces animales dans la viande et les produits à base de viande. Le dosage repose sur des réactions PCR en temps réel utilisant une nucléase marquée en 5' pour amplifier une séquence génomique unique dans l'organisme cible.
Conformément à la Directive de la commission européenne 2002/86/CE, les ingrédients alimentaires doivent être déclarés. Dans le cas de viande et de produits à base de viande, les espèces animales doivent être mentionnées sur l'étiquette. En outre, l'authenticité des espèces peut être extrêmement importante pour les consommateurs pour des raisons économiques, médicales, culturelles et religieuses. L'utilisation frauduleuse de viandes bon marché à la place d'espèces plus onéreuses, l'ajout de viande dans des produits (végétariens) non carnés et la présence d'allergènes dans les denrées alimentaires témoignent clairement de l'importance du problème (Ballin, 2010 ; Dooley et al., 2004).
Plusieurs méthodes sont basées sur l'identification de protéines au moyen de procédés électrophorétiques et/ou immunologiques. Cependant, ces méthodes n'offrent aucune fiabilité lorsqu'elles sont appliquées à des produits hautement transformés et chauffés en raison de la détérioration des protéines. L'ADN est plus stable que les protéines pendant le traitement et même s'il peut être fragmenté en plusieurs procédés, des méthodologies génétiques modernes telles que les techniques basées sur la PCR permettent toujours l'identification de l'ADN à partir de différentes espèces présentes dans un échantillon (Lockley & Bardsley, 2000). Les techniques de PCR en temps réel sont particulièrement adaptées à ces produits, car les petits fragments d'ADN peuvent toujours être amplifiés et identifiés avec une sensibilité et une spécificité élevées (Dooley et al., 2004).
Expand 6 Items
Real-Time PCR kit for detection of toxic Vibrio cholerae
Supplier: Q BIOANALYTIC
Kit for Vibrio cholerae tox gene (ctx). Food safety experts like the German DGHM recommend to test warm water fish for vibrio cholerae. With this Real-Time PCR test you have a very versatile method for testing whether or not the present strain has the ability to produce toxins. You can use our Real-Time PCR Test for Vibrio cholerae for testing for the presence of the species before. You can use this test in combination with an appropriate pre- enrichment in alkaline peptone-water or you can confirm bacterial colonies on agar plates.
Expand 4 Items
Real-Time PCR kit for detection of Staphylococcus aureus
Supplier: Q BIOANALYTIC
Real-Time kit for the detection of Staphylococcus aureus.
Expand 4 Items
Real-Time PCR kit for detection of toxic Vibrio parahaemolyticus
Supplier: Q BIOANALYTIC
Vibrio parahaemolyticus tox gene (tdh/trh): Food safety experts like the German DGHM recommend to test warm water fish for Vibrio parahaemolyticus. With this Real-Time PCR test you have a very versatile method for testing whether or not the present strain has the ability to produce toxins (tdh/trh). You can use our Real-Time PCR Test for Vibrio parahaemolyticus for testing for the presence of the species before. You can use this test in combination with an appropriate pre- enrichment in alkaline peptone-water or you can confirm bacterial colonies on agar plates.
Expand 4 Items
Real-Time PCR kit for detection of EHEC
Supplier: Q BIOANALYTIC
Testing for pathogenic E. coli like EHEC, EPEC , EIEC etc. can help to prevent foodborne infections as it has taken place in 2011 with E. coli strain O104 in Germany and with strain O157 at other places in the world. The real-time PCR kit allows the detection of stx1, stx2 and the eaeA gene which covers all different strains of pathogenic E. coli. The test can also be used for the confirmation of bacterial colonies.
Expand 3 Items
Real-Time PCR kit for detection of Vibrio alginolyticus
Supplier: Q BIOANALYTIC
Vibrio alginolyticus causes eye, ear and wound infections. It can be tested using this Real-Time PCR test. The analysis can be done in water and food samples. You can use this test in combination with an appropriate pre- enrichment in alkaline peptone-water or you can confirm bacterial colonies on agar plates.
Expand 4 Items
Real-Time PCR kit for detection of Legionella spec.
Supplier: Q BIOANALYTIC
Legionella spec. is tested usually with cultural methods. However, this may take up to 14 days to deliver results and some strains are living but are not culturable. Using this Real-Time PCR test you may have results already after a few hours. You can use this test in combination with an appropriate pre- enrichment or you can do a DNA purification directly from the filter without pre-enrichment. The kit is also suitable to confirm bacterial colonies on agar plates.
Expand 3 Items
Kits de détection PCR en temps réel pour microorganismes, QuickBlue RealQuick
Supplier: Q BIOANALYTIC
La gamme de produits RealQuick est optimisée pour la PCR en temps réel et elle utilise la technologie de sonde Taqman® pour la détection de bactéries pathogènes pour l'homme. Les kits sont généralement coordonnés de façon à pouvoir être utilisés ensemble.
Expand 4 Items
Real-Time PCR kit for detection of Vibrio cholerae
Supplier: Q BIOANALYTIC
Food safety experts like the German DGHM recommend to test warm water fish for vibrio cholerae . With this Real-Time PCR test you have a very versatile method for food testing, which can gives you results within 24 hrs. The test was developed and validated within the German Network for Vibrio Research 'VibrioNet' with many scientific institutions involved. It can be applied for food and sea water samples. In case of positive results you may be interested to determine whether or not the present strain has the ability to produce toxins. You can use our Real-Time PCR Test for toxicity gene of Vibrio cholera for this purpose VWR catalogue number: QBIAQB-RTI-19. You can use this test in combination with an appropriate pre- enrichment in alkaline peptone-water or you can confirm bacterial colonies on agar plates.
Expand 4 Items
Real-Time PCR kit for detection of Cronobacter sakazakii
Supplier: Q BIOANALYTIC
Cronobacter sakazakii (formerly Enterobacter sakazakii) is found naturally in the environment and can survive in dry conditions. It occurs in dry foods, such as powdered infant formula, milk powder and starches as well as in teas. Especially young infants are at high risk developing severe meningitis, if infected. All common Real-Time PCR block cyclers are usable for the test. Each reactions contains an internal amplification control. Therefore, false negative results due to inhibition of the reaction can be excluded. The test included the UNG enzyme to prevent re-amplification of contaminating amplicons. The test can also be used for the confirmation of bacterial colonies. The Real-Time PCR Test allows the detection of the species with high accuracy and is more precise than, cultural methods often are.
Expand 4 Items
Real-Time PCR kit for detection of EHEC and Shigella
Supplier: Q BIOANALYTIC
Testing for pathogenic E. coli like EHEC, EPEC , EIEC etc. can help to prevent foodborne infections as it has taken place in 2011 with E. coli strain O104 in Germany and with strain O157 at other places in the world. The real-time PCR kit allows the detection of stx1, stx2 and the eaeA gene which covers all different strains of pathogenic E. coli. It also includes a test for Shigella. The test can also be used for the confirmation of bacterial colonies.
Expand 4 Items
Real-Time PCR kit for the detection of the allergen hazel-nut in food samples
Supplier: Q BIOANALYTIC
Hazel-nut is allergenic for a considerable number of individuals. Using DNA based tests also processed food samples might be tested. Our Real-Time PCR test exhibits the required limit of detection laid down in the codex alimentarius. The Real-Time PCR kit has a limit of detection of ≤ 20 DNA-copies. The limit of detection can be influenced by sample matrix, level of processing, DNA-preparation and DNA-content.
Expand 3 Items
Real-Time PCR kit for detection of Vibrio vulnificus
Supplier: Q BIOANALYTIC
Vibrio vulnificus causes severe wound infections and is harmful when ingested. 33% of patients being infected die. The detection in food and water samples using this Real-Time PCR Test is very rapid and versatile. You have results available already after 24 hours. You can use this test in combination with an appropriate pre- enrichment in alkaline peptone-water or you can confirm bacterial colonies on agar plates.
Expand 4 Items
Real-Time PCR kit for detection of Pseudomonas aeruginosa
Supplier: Q BIOANALYTIC
Pseudomonas aeruginosa is tested usually with cultural methods. However, this may take several days to deliver results. Using this Real-Time PCR test you may have results already after a few hours using a DNA purification directly from filtered water without pre-enrichment. You can also use this test in combination with an appropriate pre- enrichment according to DIN EN ISO 20837. The kit is also suitable to confirm bacterial colonies on agar plates.
Expand 2 Items
Real-Time PCR kit for screening for genetically modified organisms in food and feed
Supplier: Q BIOANALYTIC
The Real-Time PCR screening kit is addressing three different targets: 35S promoter; NOS Terminator; CTP2-CP4 EPSPS. The tests are all in accordance with the JRC guideline. Advantage of the CTP2-CP4 EPSPS compared to FMV detection is that the used target includes artificial sequences, which are not present naturally like the virus sequence of FMV.
Expand 3 Items
Real-Time PCR kit for detection of Vibrio parahaemolyticus
Supplier: Q BIOANALYTIC
Food safety experts like the German DGHM recommend to test warm water fish for Vibrio parahaemolyticus. With this Real-Time PCR test you have a very versatile method for food testing, which can gives you results within 24 hrs. The test was developed and validated within the German Network for Vibrio Research “VibrioNet” with many scientific institutions involved. It can be applied for food and sea water samples. In case of positive results you may be interested to determine whether or not the present strain has the ability to produce toxins (tdh/trh). You can use our Real-Time PCR Test for toxicity gene of Vibrio cholera for this purpose VWR catalogue number: QBIAQB-RTI-50. You can use this test in combination with an appropriate pre- enrichment in alkaline peptone-water or you can confirm bacterial colonies on agar plates.
Expand 4 Items
Real-Time PCR kit for detection of pork meat in food samples
Supplier: Q BIOANALYTIC
Sus scrofa (pork) halal and kosher food does exclude pork meet. To make sure that pork meat is really absent in complex food it is advisable to test for the presence of it using our Real-Time test. Positive DNA and all required components are included in the kit.
Expand 4 Items
Real-Time PCR kit for detection of Listeria monocytogenes
Supplier: Q BIOANALYTIC
OneCup it‘s so easy! The OneCup assay comes along with a minimum of pipetting steps. Everything is included in the mix. You only need to combine 20μl of the mix with 2 μl of your DNA sample and everything is ready. You have a minimum of hands-on time and you avoid mistakes during pipetting. You can run the test on all common block cyclers. Application: Detection of Listeria monocytogenes in food samples and environmental samples subsequent to a pre-enrichment step according to DIN EN ISO 20837 and 20838.Test principle. The test is dedicated to detect DNA of Listeria monocytogenes in a sample using Real-Time PCR in compliance with the ISO method mentioned below. The kit uses the TaqMan® principle. Thus the requirements of the standard, that an amplification product has to be confirmed by a hybridization step, is fulfilled. Each reactions contains an internal amplification control. Therefore, false negative results due to inhibition of the reaction can be excluded. The test included the UNG enzyme to prevent re-amplification of contaminating amplicons.
Expand 2 Items
Real-Time PCR kit for detection of Salmonella
Supplier: Q BIOANALYTIC
OneCup it‘s so easy! The OneCup assay comes along with a minimum of pipetting steps. Everything is included in the mix. You only need to combine 20 μl of the mix with 2 μl of your DNA sample and everything is ready. You have a minimum of hands-on time and avoid mistakes during pipetting. You can run the test on all common block cyclers. Application: Detection of Salmonella in food samples and environmental samples subsequent to a pre-enrichment step according to DIN EN ISO 20837 and 20838. In combination with an appropriate pre-enrichment and DNA preparation the test complies with the official method of the German food and feed law §64. ASU L00.00-98. Test principle: The test is dedicated to detect DNA of Salmonella in a sample using Real-Time PCR in compliance with the ISO method mentioned below. The kit uses the TaqMan® principle. Thus the requirements of the ISO standard, that an amplification product has to be confirmed by a hybridization step, is fulfilled. Each reactions contains an internal amplification control. Therefore, false negative results due to inhibition of the reaction can be excluded. The test included the UNG enzyme to prevent re-amplification of contaminating amplicons.
Expand 3 Items
DNA extraction and purification kit
Supplier: Q BIOANALYTIC
Successful PCR applications depend on well purified DNA. In diagnostics and analytics of food and medical samples PCR and real-time PCR has many advantages over conventional methods. In all cases it is of importance to have well purified DNA for subsequent PCR, real-time PCR, hybridization or sequencing purposes. Purified DNA leads to higher sensitivity and also specificity of PCR based tests in difficult matrices. With QuickBlue Extraction and Purification Kit you always get high DNA yields and highly purified DNA. The kit uses paramagnetic nano-particles for purification. It can help to purify DNA from difficult matrices like food or even blood in soil for applications in forensic sciences. DNA in Seawater can also be purified. This method avoids extensive centrifugation steps and can thus be applied in environments where centrifuges are not usable. The kits includes proteinase K as a reagent for cell disruption, so that extraction and purification can be performed with the kit. DNA yield from 1 ml bacterial enrichment is 10 μg of Genomic DNA. The protocol can be adapted to automated magnetic bead separation instruments.