31 Results for: "VARLP280425VARI00013"
Water standards for Karl Fischer titration, Aquastar®, Supelco®
Supplier: Merck
Aquastar® standards for Karl Fischer titration can be used for monitoring and qualification of your Karl Fischer instruments, for checking and evaluating measuring results, and for performing titer determination of volumetric Karl Fischer reagents.
Expand 11 Items
Titrators, potentiometric and volumetric, Titroline® 7750
Supplier: SI Analytics
The Titroline® 7750 is the all-rounder for both potentiometric titration and volumetric KF titration. The titrator combines the features of the potentiometric titrator TitroLine® 7000 and the volumetric Karl Fischer titrator TitroLine® 7500.
Expand 2 Items
HYDRANAL™ - NEXTGEN solvents for Karl Fischer titration, Fluka™
Supplier: Honeywell Chemicals
Medium for volumetric two-component Karl Fischer titration (ethanol or methanol based), Free of imidazole (free of CMR substances)
Expand 2 Items
VWR®, Standards for water determination by the Karl Fischer method
Supplier: VWR Chemicals
The tightening of regulatory requirements and the increasing demands of QA/QC methodology is becoming more important across all market sectors. The demand for standards to support testing methods continues to increase, and this growth applies to water determination according to Karl Fischer. Avantor now offers a complete range of Karl Fischer water standards as CRMs to calibrate and monitor equipment and check test results.
Expand 27 Items
VWR® TITRINORM®, pH Buffers, for Karl Fischer Titrations
Supplier: VWR Chemicals
The volumetric and coulometric reagents are buffered systems, stabilised around the ideal value between 5 to 7 ensuring a rapid and stoichiometric course of reaction. Buffering systems which neutralise and stabilise the pH during the reaction are suitable for this purpose.
Expand 1 Items
VWR®, Coulometric reagents for water determination by the Karl Fischer method
Supplier: VWR Chemicals
Both anolyte and catholyte solutions are with improved formulation to increase the speed and accuracy of titration when determining water content at the microgram level.
Expand 10 Items
J.T.Baker® HYDRA-POINT™, Volumetric Reagents for Water Determination by Karl Fischer titration
Supplier: Avantor
No matter what your requirements are for volumetric systems, HYDRA-POINT™ Karl Fischer reagents make water determination easy and trouble-free. They are pyridine-free and specially formulated for existing application procedures to give you consistent, reliable results for all types of samples.
Expand 19 Items
VWR®, Volumetric reagents for water determination by the Karl Fischer method
Supplier: VWR Chemicals
These reagents are ideal for water determination including the analysis of aldehydes and ketones.
Expand 23 Items
Titrators, Karl Fischer, coulometric, TitroLine® 7500 KF Trace
Supplier: SI Analytics
These very compact, easy to operate instruments are ideal for coulometric water determination according to Karl Fischer in low water content, as well as for bromine number determination. They are suitable for small liquid or gaseous sample amounts, and can be used for quality control in the chemical, petrochemical, pharmaceutical and food industries.
Expand 6 Items
Titrators, Karl Fischer, volumetric, TitroLine® 7500 KF
Supplier: SI Analytics
TitroLine® 7500 KF is a volumetric generalist for a wide range of uses. Applications include KF volumetry, dead-stop titrations (SO₂, bromine number), dosing tasks and preparation of solutions. Ideal for KF analysis in pharmaceutical, chemical, food and mineral oil industries.
Expand 3 Items
Titrator, Karl Fischer, volumetric, TitroLine® 7800
Supplier: SI Analytics
The Titroline® 7800 enhanced the universal features of the TitroLine® 7750 (potentiometric titration and volumetric KF titration), with an additional IDS measurement socket. Hence the TitroLine® 7800 is able to perform potentiometric titrations with analogue or IDS® electrodes as well as volumetric Karl Fischer titrations. The digital (IDS) measurement socket allows the connection of various digital sensors, such as for measuring of conductivity.
Expand 3 Items
Coulomat oils for Karl Fischer titration, HYDRANAL™
Supplier: Honeywell Chemicals
Coulomat oil is a reagent for coulometric KF titration in oils (anolyte solution), preferred to use for the cells with diaphragm.
Expand 4 Items
HYDRANAL™ - NEXTGEN Coulomat C-FA, Catholyte for Coulometric Karl Fischer Titration, Fluka™
Supplier: Honeywell Chemicals
Catholyte for coulometric Karl Fischer titration of ketones and Li-ion battery electrolytes, Acetonitrile-based, free of alcohols (free of CMR substances)
Expand 2 Items
HYDRANAL™ - NEXTGEN Coulomat A-FA, Anolyte for Coulometric Karl Fischer Titration, Fluka™
Supplier: Honeywell Chemicals
Anolyte for coulometric Karl Fischer titration of ketones and Li-ion battery electrolytes, preferred for cells with diaphragm, acetonitrile-based, free of alcohols (free of CMR substances)
Expand 3 Items
Formamide, dry, Hydranal™ solubilizer for Karl Fischer titration, Fluka™
Supplier: Honeywell Chemicals
Formamide, dry, Hydranal™ solubilizer for Karl Fischer titration, Fluka™
Expand 2 Items
Karl Fischer reagents, buffer for bases, HYDRANAL™
Supplier: Honeywell Chemicals
Liquid buffer medium for Karl Fischer titration in alkaline samples (based on salicylic acid).
Expand 2 Items
, Hydranal™ drying agent, for air and gases for Karl Fischer titration, Ø ~2 mm, Fluka™
Supplier: Honeywell Chemicals
, Hydranal™ drying agent, for air and gases for Karl Fischer titration, Ø ~2 mm, Fluka™
Expand 1 Items
Reagents for Karl Fischer titrations, Aquastar®, Supelco®
Supplier: Merck
The Aquastar® range is designed to provide reagents for the determination of water by Karl Fischer titration of a wide range of substrates and by a variety of methodologies. These include reagents for one- or two-component systems; combined coulometric reagents; solvents for oils and fats; reagents and solvents for determination of water in ketones and aldehydes. Calibration standards are also available.
Expand 40 Items
Benzoic acid, Certipur® Reag. USP, Reag. Ph. Eur. volumetric standard, secondary reference material for alkalimetry, traceable to NIST Standard Reference Material (SRM), Supelco®
Supplier: Merck
Benzoic acid, Certipur® Reag. USP, Reag. Ph. Eur. volumetric standard, secondary reference material for alkalimetry, traceable to NIST Standard Reference Material (SRM), Supelco®
Expand 2 Items
Reagents for water determination by the Coulometric Titration Karl Fischer method, Hydranal™
Supplier: Honeywell Chemicals
Coulometric Karl Fischer titrations normally require two reagent solutions: an anolyte (the solution in the anodic compartment) and a catholyte (the solution in the cathodic compartment).
Expand 22 Items
Chloroform, Hydranal™ solubilizer for Karl Fischer titration, Fluka™
Supplier: Honeywell Chemicals
Chloroform, Hydranal™ solubilizer for Karl Fischer titration, Fluka™
Expand 2 Items
Karl fischer reagents, Fluka™
Supplier: Honeywell Chemicals
Karl fischer reagents can be used for for pyridine-based volumetric KF titration.
Expand 4 Items
HYDRANAL™ humidity absorber for Karl Fischer titration
Supplier: Honeywell Chemicals
HYDRANAL™ Humidity absorber is a drying agent for air and gases for Karl Fischer titration (with indicator).
Expand 3 Items
Water standards, CRM, Karl Fischer titration, HYDRANAL™, Fluka™
Supplier: Honeywell Chemicals
Certified reference material for Karl Fischer titration, exact value on certificate of analysis.
Expand 3 Items
Reagent for volumetric KF titration, HYDRANAL™
Supplier: Honeywell Chemicals
Buffer acid buffer substance for KF titration, HYDRANAL™, Glass bottle
Expand 2 Items
HYDRANAL™ - NEXTGEN Coulomat AG-FI, Anolyte for Coulometric Karl Fischer Titration, Fluka™
Supplier: Honeywell Chemicals
Anolyte for coulometric Karl Fischer titration, for cells with and without diaphragm, Methanol-based, free of Imidazole (free of CMR substances).
Expand 1 Items
Water standards for Karl Fischer titration, Hydranal™
Supplier: Honeywell Chemicals
Broad product range for volumetric and coulometric Karl Fischer applications, as well as the indirect oven application.
Expand 21 Items
Karl Fischer reagents, buffer substances, HYDRANAL™, Fluka™
Supplier: Honeywell Chemicals
Salicylic acid, HYDRANAL™, Plastic bottle
Expand 3 Items
o-Xylene, Hydranal™ solubilizer for Karl Fischer titration, Fluka™
Supplier: Honeywell Chemicals
o-Xylene, Hydranal™ solubilizer for Karl Fischer titration, Fluka™
Expand 2 Items
Titrants and reagents for volumetric Karl Fischer titrations, HYDRANAL™, Fluka™
Supplier: Honeywell Chemicals
HYDRANAL™-Composite is a frequently used pyridine-free Karl Fischer reagent. This one-component reagent has been proving its capabilities in volumetric titration for more than thirty five years in a large range of applications in the most diverse fields of research and industry.
The one component system have the following advantages: