22 Results for: "EUPROMOHITS000005"
VWR®, Fittings for Capillary Connector
Supplier: VWR Collection
Choose the suitable fitting for your tubing size.
Expand 4 Items
J.T.Baker® BAKERBOND®, Supported Liquid Extraction Plates
Supplier: Avantor
J.T.Baker® BAKERBOND® supported liquid extraction (SLE) plates are an ideal and faster alternative to traditional liquid-liquid extraction methods and allow excellent recoveries of analytes from biological matrices.
Expand 4 Items
J.T.Baker® BAKERBOND®, Protein Precipitation Plates
Supplier: Avantor
J.T.Baker® BAKERBOND® protein precipitation plates enable fast protein removal from biological samples.
Expand 2 Items
VWR®, TLC Aluminium Plates, Silica, Unmodified Layers
Supplier: VWR Collection
These TLC aluminium plates are suitable for easy and quick sample applications. They are flexible and can be cut to match different plate size requirements.
Expand 5 Items
Pipette controller, accu-jet® S
Supplier: Brand
The accu-jet® S pipette controller brings versatility and endurance to your team. It makes lab work simple, easy, and efficient, whether you work with cell cultures, in quality control or in a pharma lab.
Expand 8 Items
J.T.Baker®, Syringe Filters
Supplier: Avantor
These syringe filters are specifically designed for chromatography sample preparation applications and optimised to provide the most consistent results with less extractables.
Expand 92 Items
TLC plates, aluminium oxide 60
Supplier: Merck
Merck TLC aluminium oxide plates use neutral or basic aluminium oxide of 60 or 150 Å pore size with or without fluorescent indicator to suit different application needs. Under aqueous conditions, basic compounds can be best separated on basic aluminium oxide plates, while neutral compounds are best separated on neutral plates.
Expand 4 Items
HPTLC plates with spherical particles, LiChrospher®
Supplier: Merck
HPTLC LiChrospher® plates are based on spherical-shaped silica 60 with a particle size of 7 µm, and narrow particle size distribution similar to the phases used in HPLC. LiChrospher® HPTLC plates possess a selectivity that is comparable to respective HPTLC plates, however, plate height and separation numbers are further improved resulting in shorter analysis times.
Expand 3 Items
Avantor® ACE® UltraCore Phenyl Hexyl, Analytical HPLC/UHPLC Columns
Supplier: Avantor
Avantor® ACE® UltraCore Phenyl Hexyl are high performing solid-core (core-shell) particle columns designed for a range of chromatographic applications and is especially well suited for retention of aromatic compounds where π-π interactions can be exploited.
Expand 12 Items
Avantor® ACE® UltraCore C18-Amide, Analytical HPLC/UHPLC Columns
Supplier: Avantor
Avantor® ACE® UltraCore C18-Amide are high performing solid-core (core shell) particle columns designed for a range of reversed-phase chromatographic applications. Additional mechanisms of interaction such as H-bonding give an alternative selectivity for moderately polar analytes.
Expand 12 Items
HPTLC and GLP plates, silica gel 60, unmodified layers, glass backed
Supplier: Merck
HPTLC plates, unmodified silica gel 60
This range of plates uses an optimised Merck silica gel 60 with a particle size of only 5 to 6 µm, which results in higher packing density and a smoother surface, therefore, reducing band diffusion. Less sample is required, 0,1 to 0,5 µl than for classic TLC.
Expand 21 Items
TLC and GLP plates, silica gel 60, unmodified layers, glass backed
Supplier: Merck
TLC plates, unmodified silica gel 60
Merck silica gel 60 has a unique polymeric binder that results in a uniform, hard surface that will not easily crack or blister. This smooth, extremely dense plate coating ensures narrow bands and maximum separation efficiency with the lowest background noise. Layer thickness 250 μm and particle size of 10 to 12 µm. Two inorganic fluorescent indicators for UV detection of colourless substances.
Expand 17 Items
Avantor® ACE® UltraCore Biphenyl, Analytical HPLC/UHPLC Columns
Supplier: Avantor
Avantor® ACE® UltraCore Biphenyl are high performing solid-core (core-shell) particle columns, designed for a range of chromatographic applications and is especially well suited for retention of aromatic compounds that elute early on alkyl phases.
Expand 12 Items
Chromatography papers
Supplier: Ahlstrom-Munksjö
Ahlstrom-Munksjö offers a full range of high quality cotton papers with high absorbency - ideal for chromatographic analysis and blotting methods with gel (Southern, Northern and Western Blots). Ahlstrom-Munksjö manufactures, both in Europe and in the US, absorbent papers made of the highest purity cotton linters. These media do not contain additive of any kind, thus preventing any contamination during the transfer steps.
Expand 15 Items
LC columns, MAbPac™ RP
Supplier: Thermo Fisher Scientific
These columns are designed for high performance reversed-phase HPLC and LC-MS characterisation of monoclonal antibodies (mAbs), fragments, variants, antibody drug conjugates (ADCs), PEGylated proteins and bispecific proteins.
Expand 10 Items
EZ-fill® Vials, Stevanato Group
Supplier: DWK Life Sciences
EZ-fill® Vials, offered in nest and tub and trays.
Expand 10 Items
Avantor® ACE® UltraCore C18, Analytical HPLC/UHPLC Columns
Supplier: Avantor
Avantor® ACE® UltraCore C18 are high performing solid-core (core-shell) particle columns designed for a wide range of LC applications. This densely bonded octadecyl phase can be used to separate acidic, basic and neutral molecules, based on hydrophobic retention mechanisms.
Expand 12 Items
TLC plates, silica gel 60, unmodified and chemically modified layers, aluminium backed
Supplier: Merck
TLC plates, unmodified silica gel 60
This range of plates uses Merck silica gel 60 with a unique polymeric binder that results in a uniform, hard surface that will not easily crack or blister. The smooth, extremely dense plate coating ensures narrow bands and maximum separation efficiency with the lowest background noise. Layer thickness 200 μm and, particle size of 10 to 12 µm. Flexible aluminium plates that can easily be cut to match individual separation requirements. Two inorganic fluorescent indicators for UV detection of colourless substances. Samples which absorb shortwave UV at 254 nm are detected due to fluorescence quenching.
Expand 15 Items
Magnetic hotplate stirrer, RCT basic
Supplier: IKA
The RCT basic magnetic stirrer provides reliability, an exceptionally long product lifetime and the highest safety standards. RCT basic is suitable for stirring tasks up to 20 L (H₂O) and reaches temperatures up to 310 °C. With the connection option for an external temperature sensor (PT1000.60), the temperature can be measured and controlled directly in the reaction medium. Thanks to insulation of the aluminium heating plate, maintenance-free EC motor and electronic switching power supply, RCT basic features excellent energy efficiency as well as reduced self-heating of the heating plate during stirring operation, contributing to a more sustainable laboratory.
Expand 1 Items
Glass crimp top vials, 2 ml, level 2 high-throughput applications, SureSTART™
Supplier: Thermo Fisher Scientific
Choose Thermo Scientific™ SureSTART™ 2 ml glass crimp top vials, performance level 2, to ensure high quality data with an uninterrupted workflow in high-throughput applications using GC, HPLC/UHPLC, and single or triple quadrupole MS systems.
Expand 6 Items
Glass crimp top headspace vials, 10 ml, level 2 high-throughput applications, SureSTART™
Supplier: Thermo Fisher Scientific
Use Thermo Scientific™ SureSTART™ 10 ml glass crimp top headspace vials in your high-throughput volatile gas analyses. Performance level 2 vials ensure high quality data with an uninterrupted workflow in high-throughput applications using GC and single or triple quadrupole MS systems.
Expand 6 Items
Glass screw top vials, 2 ml, level 2 high-throughput applications, SureSTART™
Supplier: Thermo Fisher Scientific
Choose Thermo Scientific™ SureSTART™ 2 ml glass screw top vials, performance level 2, to ensure high quality data with an uninterrupted workflow in high-throughput applications using GC, HPLC/UHPLC, and single or triple quadrupole MS systems. Use level 2 vials for routine QA/QC applications, where the analyte levels are achievable or close to the method detection level. Available in clear and amber glass, these 2 ml screw top vials have very low metal content, extractables, and leachables and conform to high standards so that you can to meet your regulatory requirements. They are specification certified to ensure their physical dimensions and autosampler compatibility.