12 Results for: "CX1-pH Gradient Buffers"
VWR® PerfectBlue Maxi ExW 'Revolution', Wide format gel system
Supplier: VWR Collection
The Maxi ExW 'Revolution' offers built-in buffer recirculation - without the need for pumps or additional tubing. The Maxi ExW 'Revolution' offers the same high throughput, rapid separation as the Maxi ExW model but, with the position of the cathode and a rising tube, the system uses hydrogen bubbles to slowly mix the buffer. This system thereby avoids the build-up of pH or ionic gradients for electrophoresis of maximum quality and stability.
Expand 1 Items
VWR® PerfectBlue Maxi M 'Revolution', Gel system
Supplier: VWR Collection
Based on the Maxi M model, the Maxi M 'Revolution' offers a built-in buffer circulation system, powered by the system’s electrodes. At the cathode, hydrogen bubbles are produced and pass up a diagonally positioned pipe connected to the two sides of the tank to produce a gentle and continual circulation of the buffer. The system nulls any pH and ionic gradient – without the fuss of mechanical pumps. The system offers 6 comb positions enabling the gel to be partitioned into 2, 3 or 4 areas. In addition, the system can accommodate any of the 23 standard and microtitre comb designs described for the Maxi M model.
Expand 1 Items
VWR® PerfectBlue Mini L Revolution, Gel System
Supplier: VWR Collection
The 'Revolution' series includes a buffer circulation system, powered by the electrodes themselves. Hydrogen bubbles produced at the cathode pass up a diagonally positioned pipe connected to the two sides of the tank producing a gentle circulation of the buffer. The result is no pH and ionic gradient – without need of mechanical pumps.
Expand 1 Items
Peqlab PerfectBlue Maxi M 'Revolution', Gel system
Supplier: VWR Peqlab
Based on the Maxi M model, the Maxi M 'Revolution' offers an in-built buffer circulation system, powered by the system's electrodes. At the cathode, hydrogen bubbles are produced and pass up a diagonally positioned pipe connected to the two sides of the tank to produce a gentle and continual circulation of the buffer. The system nulls any pH and ionic gradient – without the fuss of mechanical pumps. The system offers 6 comb positions enabling the gel to be partitioned into 2, 3 or 4 areas. Additionally, the system can accommodate any of the 23 standard and microtitre comb designs described for the Maxi M model.
Expand 1 Items
pH Buffer solutions, CX-1
Supplier: Thermo Fisher Scientific
Delivers robust reproducible gradients with the Thermo Scientific™ pH buffer platform that is applicable to a wide range of MAbs and ready to use with existing LC columns and systems, without the need to formulate mobile phases.
Expand 4 Items
Mini horizontal gel electrophoresis systems, Owl™ B2 EasyCast™ and B3
Supplier: THERMO OWL SCIENTIFIC
The Owl™ B2 EasyCast™ mini horizontal gel system provides flexibility in a small footprint and is available with or without buffer exchange ports. The Owl™ B3 with built-in recirculation system prevents formation of pH and ionic gradients for high resolution and uniform reproducible results. The Owl™ B3 is ideal for long runs, multiple sample sets or RNA gels. It also eliminates uneven migration, band distortion or disassociation of pH dependent glycoxylated RNA molecules that can result when ionic depletion occurs. As the recirculation system is built into the buffer chamber, no external pumps, tubing or stirring bars are required.
Expand 1 Items
Rehydration reagent, DeStreak
Supplier: Cytiva
The appearance of streaks that distort 2-D electrophoresis maps is a common problem, occurring most frequently when running gels that contain regions greater than pH 7,0. Increased sample load, increased length of the IPG strip, or using a narrower pH gradient worsens the problem. Extra spots on 2-D gels, caused by non specific oxidation of proteins, is another difficulty encountered when running gels containing basic regions. Both streaking and non specific oxidation result in poorly resolved protein patterns and reduced reproducibility between electrophoresis runs.
Expand 1 Items
Large horizontal gel electrophoresis systems, Owl™ A2 and A5
Supplier: THERMO OWL SCIENTIFIC
The Owl™ A2 horizontal gel system is a simple, convenient and fast system for detailed DNA/RNA analysis on multiple samples. It is available with or without buffer exchange ports. The Owl A5 large gel system with built-in recirculation prevents formation of pH and ionic gradients for high resolution and uniform reproducible results. The Owl A5 is ideal for long runs, multiple sample sets or RNA gels. It also eliminates uneven migration, band distortion or disassociation of pH dependent glycoxylated RNA molecules that can result when ionic depletion occurs.
Expand 2 Items
CX-1 PH GRADIENT BUFFER B, PH 10.2, 1L 1 * 1 items
Supplier: Thermo Fisher Scientific
CX-1 PH GRADIENT BUFFER B, PH 10.2, 1L 1 * 1 items
Expand 1 Items
BUFFER B CX-1 PH 10.2 , CX-1 PH GRADIENT BUFFER B (PH 10.2) 500ML 1 * 500 mL
Supplier: Thermo Fisher Scientific
BUFFER B CX-1 PH 10.2 , CX-1 PH GRADIENT BUFFER B (PH 10.2) 500ML 1 * 500 mL
Expand 1 Items
CX-1 PH GRADIENT BUFFER A (PH 5.6) 500ML 1 * 500 mL
Supplier: Thermo Fisher Scientific
CX-1 PH GRADIENT BUFFER A (PH 5.6) 500ML 1 * 500 mL
Expand 1 Items
Lysates, human
Supplier: Rockland Immunochemicals
Whole cell lysates are derived from cell lines tissues using highly refined extraction protocols to ensure quality, protein integrity and high reproducibility. Lysates are prepared in denaturing buffer without dissociating agents.