You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Capillary columns, VF-WAXms
Supplier: VARIAN
VF-WAXms is a high performance column for applications in the food, flavours and fragrances markets, and especially where trace analyses are required.
Expand 25 Items
Capillary columns, CP-Sil 5 CB for Formaldehyde
Supplier: VARIAN
CP-Sil 5 CB for Formaldehyde is optimized for the analysis of formaldehyde, water and methanol, and can deliver trace analysis of sulfur compounds and partial permanent gases.
Expand 2 Items
HPLC columns, MetaSil® Basic
Supplier: VARIAN
MetaSil® Basic columns tends to retain polar compounds better than standard phases, often showing improved retention for compounds that elute in the void volume on standard alkyl phases. These columns are recommended for use at pH 2 to 7,5.
Expand 4 Items
Capillary columns, CP-Wax 57 CB
Supplier: VARIAN
CP-Wax 57 CB for Glycols and Alcohols is guaranteed for the analysis of glycols, diols and alcohols. It has a unique, high polarity wax phase that produces symmetrical peaks.
Expand 2 Items
Capillary columns, CP-Sil 5/C₁₈ CB for PCB
Supplier: VARIAN
CP-Sil 5/C₁₈ CB for PCB has a lower polarity than 100% polydimethylsiloxane due to its C₁₈ substitutions. Due to the absence of cyano groups it provides high signal-to-noise ratios for ECD detectors.
Expand 2 Items
GC columns, J&W CP-Wax 58 FFAP CB
Supplier: VARIAN
Agilent JW CP-Wax 58 FFAP CB column is a nitroterephthalic acid-modified, chemically bonded polyethylene glycol phase.
Expand 7 Items
Preparative columns, PLgel™
Supplier: VARIAN
These preparative columns is ideal to fractionate polymers, isolate components in a polymer formulation or simplify mixtures of relatively small molecules in complex matrices.
Expand 10 Items
High efficiency purification columns, biomolecule seperation
Supplier: VARIAN
Column type: HPLC column, PLRP-S, Seperation of macromolecular plasmids by anion exchange, Ø int.: 7,50 mm, Length: 50 mm, Pore size: 4000 Å, Particle size: 8 µm
Expand 11 Items
Capillary columns, Select PAH
Supplier: VARIAN
Select PAH is the first capillary column that provides a single solution for PAH analysis by separating all the isomers, thereby avoiding false positives and inaccurate results.
Expand 2 Items
SPE cartridge, iSPE®-HILIC
Supplier: HICHROM
Designed for operated in positive ionization mode for analysis of standards.
Expand 4 Items
Capillary columns, CP-Sil 8 CB for amines
Supplier: VARIAN
CP-Sil 8 CB for amines is a base-deactivated 5% phenyl polydimethylsiloxane column that can be used for a wide range of amines.
Expand 8 Items
GC columns, J&W CP-Wax 57 CB
Supplier: VARIAN
CP-Wax 57 CB has a unique selectivity, especially for the analysis of alcohols in the brewing and wines/spirits industry.
Expand 5 Items
Capillary columns, VF-200ms
Supplier: VARIAN
VF-200ms is designed with a unique selectivity for compounds rich in dipole-dipole interactions, resulting from the electrophilic nature of the trifluoropropyl stationary phase.
Expand 12 Items
Capillary columns, VF-23ms
Supplier: VARIAN
VF-23ms features a unique combination of high polarity and low bleed to enable more accurate analysis of very polar analytes.
Expand 9 Items
Strong cation exchange HPLC columns, PL-SCX
Supplier: VARIAN
Macroporous PS/DVB matrix with a very hydrophilic coating and strong cation exchange functionality provide good mass transfer characteristics for a range of solute sizes.
Expand 23 Items
Solid phase extraction cartridges, Bond Elut™ C2
Supplier: VARIAN
Bond Elut™ C2 is a fairly non-polar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions.
Expand 10 Items
Bond Elut™ SAX SPE cartridges
Supplier: VARIAN
Bond Elut™ SAX is a strong anion-exchanger suited for extracting weak anions such as carboxylic acids that may not retain well on weak anion-exchangers.
Expand 3 Items
SPE cartridges, Bond Elut™ Plexa PAX
Supplier: VARIAN
Bond Elut™ plexa PAX non-polar/anion-exchange polymeric SPE offers excellent clean-up and reproducibility, and is suitable for polar and non-polar acidic analytes.
Expand 2 Items
Solid phase extraction cartridges, Bond Elut™ C18
Supplier: VARIAN
Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.
Expand 43 Items
Solid phase extraction cartridges, Bond Elut™ LMS
Supplier: VARIAN
Bond Elut™ LMS polymeric sorbent lets you elute without having to add amine modifiers, buffers, or acids. The elimination of secondary interactions means that elution of analytes can be achieved with pure organic solvents or HPLC mobile phase-compatible solvent mixtures of low ionic strength. These characteristics are crucial to allow compatibility with LC/MS or other delicate analytical techniques.
Expand 6 Items
Cation exchange chromatography columns, TSK-GEL® SP-NPR
Supplier: TOSOH Bioscience
TSK-Gel® SP-NPR are polymer based stainless steel columns. These columns provide fast separations due to their small spherical particles.
Expand 1 Items
Solid phase extraction cartridges, Bond Elut™ NEXUS and NEXUS WCX
Supplier: VARIAN
Bond Elut™ NEXUS is an ultra-clean polymeric sorbent which has bi-modal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no pre-conditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine.
Based on the same base polymer technology, Bond Elut™ NEXUS WCX is a weak cation exchange sorbent that offers extra selectivity for analytes, such as quaternary ammonium drugs and anabolic steroids.
Expand 8 Items
Solid phase extraction cartridges, Bond Elut™ PPL
Supplier: VARIAN
Bond Elut™ PPL is a styrene-divinylvenzene (SDVB) polymer that has been modified with a proprietary non-polar surface. PPL will retain even the most polar classes of analytes, including phenols. The large particle size allows ease of flow for viscous or particulate rich water samples, while the high surface area and strong hydrophobicity ensure reproducible extractions with high recoveries upon elution. Bond Elut™ PPL is suitable for EPA Method 528 ‘Determination of Phenols in Drinking Water by SPE and Capillary GC/MS’.
Expand 9 Items
Omnifit® EZ SolventPlus™ Glass Chromatography Columns for FPLC and LPLC
Supplier: OMNIFIT
EZ SolventPlus™ columns are designed for maximum chemical compatibility. Borosilicate glass and PTFE construction, with Chemraz® o-rings and PTFE frits, only the most inert materials are present in the fluid path. ETFE end caps and fitting nuts ensure a chemically inert connection into and out of the system.
Expand 21 Items
Anion exchange chromatography columns, TSK-GEL®, DEAE
Supplier: TOSOH Bioscience
TSK-Gel® DEAE is a strong anion exchange resin composed of highly cross-linked polymethacrylate beads for bimolecule purification.
Expand 13 Items
Capillary columns, VF-35ms
Supplier: VARIAN
VF-35ms is a medium polarity column, which is the ideal choice for trace environmental and chemical analyses, and as a confirmation column.
Expand 11 Items
HPLC columns, Chromspher
Supplier: VARIAN
Column type: HPLC column, Chromspher Si, Ø int.: 4,60 mm, Length: 250 mm, Pore size: 120 Å, Particle size: 5 µm
Expand 3 Items
PLOT columns, CP-PoraPLOT Amines
Supplier: VARIAN
CP-PoraPLOT Amines is a unique column specially designed for the high retention analysis of very volatile amines.
Expand 2 Items
HPLC Columns, OPTIMAPACK
Supplier: HICHROM
OPTIMAPAK is a range of HPLC columns which are available in three bonded phases and an unbonded silica phase.
Expand 2 Items
Capillary columns, CP-Cyclodextrin-β-2,3,6-M-19
Supplier: VARIAN
The CP-Cyclodextrin-β-2,3,6-M-19 column separates many optical isomers that could not be analyzed previously.