Pure water systems, Milli-Q® IX 7003/05/10/15
Supplier: Merck
Certificates
About this item
Reliable water purification for results reproducibility and lab productivity.
- Constant-quality Elix® pure water
- Intuitive E-POD® dispenser (optional)
- Touchscreen interface
- New pure water storage solution
- Elix® EDI technology lowers running costs
- Mercury-free UV lamps
The Milli-Q IX pure water system provides a reliable source of high quality type 2 pure water to feed your lab's needs: From general laboratory uses, such as instrument feed or buffer preparation, to sensitive applications, such as microbiology culture media or staining solutions.
Advanced and ergonomic E-POD point of dispense (optional) gives rapid and convenient access to pressurised pure water throughout the lab.
Certifications: Manufactured in accordance to IECEE; UL listed; ASTM® D1193 (type 2 reagent water); ISO® 3696 (grade 2 water).
Ordering information: A range of accessories are available to support your specific needs and environment; contact your Avantor representative for more information.
Specifications
- Catalog No:
- 172-0055
- 172-0061
- 172-0056
- 172-0057
- 172-0058
- 172-0059
- 172-0060
- 172-0062
- Modell:
- Milli-Q® IX 7003
- Milli-Q® IX 7015
- Milli-Q® IX 7003
- Milli-Q® IX 7005
- Milli-Q® IX 7005
- Milli-Q® IX 7010
- Milli-Q® IX 7010
- Milli-Q® IX 7015
- Speisewasser:
- Potable tap water
- Potable tap water
- Potable tap water
- Potable tap water
- Potable tap water
- Potable tap water
- Potable tap water
- Potable tap water
- Produktionsfließrate:
- 3 L/h
- 15 L/h
- 3 L/h
- 5 L/h
- 5 L/h
- 10 L/h
- 10 L/h
- 15 L/h
- Leitfähigkeit:
- <0,2 μS/cm at 25 °C, typically 0,1 μS/cm (values are typical and may vary depending on the feed water)
- <0,2 μS/cm at 25 °C, typically 0,1 μS/cm (values are typical and may vary depending on the feed water)
- <0,2 μS/cm at 25 °C, typically 0,1 μS/cm (values are typical and may vary depending on the feed water)
- <0,2 μS/cm at 25 °C, typically 0,1 μS/cm (values are typical and may vary depending on the feed water)
- <0,2 μS/cm at 25 °C, typically 0,1 μS/cm (values are typical and may vary depending on the feed water)
- <0,2 μS/cm at 25 °C, typically 0,1 μS/cm (values are typical and may vary depending on the feed water)
- <0,2 μS/cm at 25 °C, typically 0,1 μS/cm (values are typical and may vary depending on the feed water)
- <0,2 μS/cm at 25 °C, typically 0,1 μS/cm (values are typical and may vary depending on the feed water)
- TOC-Gehalt:
- ≤30 ppb (values are typical and may vary depending on the feed water)
- ≤30 ppb (values are typical and may vary depending on the feed water)
- ≤30 ppb (values are typical and may vary depending on the feed water)
- ≤30 ppb (values are typical and may vary depending on the feed water)
- ≤30 ppb (values are typical and may vary depending on the feed water)
- ≤30 ppb (values are typical and may vary depending on the feed water)
- ≤30 ppb (values are typical and may vary depending on the feed water)
- ≤30 ppb (values are typical and may vary depending on the feed water)
- Spezifischer Widerstand bei +25 °C:
- >5 MΩ.cm, 10 - 15 MΩ.cm (typical) [resistivity can also be displayed non temperature compensated as required by USP]
- >5 MΩ.cm, 10 - 15 MΩ.cm (typical) [resistivity can also be displayed non temperature compensated as required by USP]
- >5 MΩ.cm, 10 - 15 MΩ.cm (typical) [resistivity can also be displayed non temperature compensated as required by USP]
- >5 MΩ.cm, 10 - 15 MΩ.cm (typical) [resistivity can also be displayed non temperature compensated as required by USP]
- >5 MΩ.cm, 10 - 15 MΩ.cm (typical) [resistivity can also be displayed non temperature compensated as required by USP]
- >5 MΩ.cm, 10 - 15 MΩ.cm (typical) [resistivity can also be displayed non temperature compensated as required by USP]
- >5 MΩ.cm, 10 - 15 MΩ.cm (typical) [resistivity can also be displayed non temperature compensated as required by USP]
- >5 MΩ.cm, 10 - 15 MΩ.cm (typical)
- Bakterien:
- ≤10 cfu/L [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters or Biopak® polisher when installed and used in a laminar flow hood)
- ≤10 cfu/L [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters or Biopak® polisher when installed and used in a laminar flow hood)
- ≤10 cfu/L [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters or Biopak® polisher when installed and used in a laminar flow hood)
- ≤10 cfu/L [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters or Biopak® polisher when installed and used in a laminar flow hood)
- ≤10 cfu/L [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters or Biopak® polisher when installed and used in a laminar flow hood)
- ≤10 cfu/L [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters or Biopak® polisher when installed and used in a laminar flow hood)
- ≤10 cfu/L [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters or Biopak® polisher when installed and used in a laminar flow hood)
- ≤10 cfu/L [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters or Biopak® polisher when installed and used in a laminar flow hood)
- Partikel:
- No particulates with size >0,22 µm [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters)
- No particulates with size >0,22 µm [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters)
- No particulates with size >0,22 µm [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters)
- No particulates with size >0,22 µm [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters)
- No particulates with size >0,22 µm [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters)
- No particulates with size >0,22 µm [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters)
- No particulates with size >0,22 µm [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters)
- No particulates with size >0,22 µm [from an E-POD® dispenser with final filter] (with Millipak® or Millipak® Gold filters)
- Endotoxin:
- <0,001 EU/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher when installed and used in a laminar flow hood)
- <0,001 EU/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher when installed and used in a laminar flow hood)
- <0,001 EU/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher when installed and used in a laminar flow hood)
- <0,001 EU/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher when installed and used in a laminar flow hood)
- <0,001 EU/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher when installed and used in a laminar flow hood)
- <0,001 EU/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher when installed and used in a laminar flow hood)
- <0,001 EU/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher when installed and used in a laminar flow hood)
- <0,001 EU/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher when installed and used in a laminar flow hood)
- RNasen:
- <1 pg/ml [From an E-POD® dispenser with final filter] (with Biopak® polisher)
- <1 pg/ml [From an E-POD® dispenser with final filter] (with Biopak® polisher)
- <1 pg/ml [From an E-POD® dispenser with final filter] (with Biopak® polisher)
- <1 pg/ml [From an E-POD® dispenser with final filter] (with Biopak® polisher)
- <1 pg/ml [From an E-POD® dispenser with final filter] (with Biopak® polisher)
- <1 pg/ml [From an E-POD® dispenser with final filter] (with Biopak® polisher)
- <1 pg/ml [From an E-POD® dispenser with final filter] (with Biopak® polisher)
- < 1 pg/ml [From an E-POD® dispenser with final filter] (with Biopak® polisher)
- DNasen:
- <5 pg/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher)
- <5 pg/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher)
- <5 pg/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher)
- <5 pg/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher)
- <5 pg/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher)
- <5 pg/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher)
- <5 pg/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher)
- <5 pg/ml [from an E-POD® dispenser with final filter] (with Biopak® polisher)
- B×T×H:
- 315×380×498 mm (12,4×15×19,6")
- 375×380×498 mm (14,8×15×19,6")
- 315×380×498 mm (12,4×15×19,6")
- 315×380×498 mm (12,4×15×19,6")
- 315×380×498 mm (12,4×15×19,6")
- 375×380×498 mm (14,8×15×19,6")
- 375×380×498 mm (14,8×15×19,6")
- 375×380×498 mm (14,8×15×19,6")
- Gewicht:
- 23,4 kg (POD unit operation weight: 5,5 kg)
- 27,4 kg (POD unit operation weight: 5,5 kg)
- 23,4 kg
- 23,4 kg (POD unit operation weight: 5,5 kg)
- 23,4 kg
- 27,1 kg (POD unit operation weight: 5,5 kg)
- 27,1 kg
- 27,4 kg
Specifications