Multi-parameter meter (pH/mV/conductivity), bench, Orion Star™ A215
Multi-parameter meter (pH/mV/conductivity), bench, Orion Star™ A215
Supplier:  Thermo Orion
Certificates
undefined
Multi-parameter meter (pH/mV/conductivity), bench, Orion Star™ A215
Supplier:  Thermo Orion

Specifications

  • Catalog No:
  • 665-0272
  • 665-0271
  • Modell:
  • A215
  • A215
  • pH - Bereich:
  • –2,000...+20,000
  • –2,000...+20,000
  • pH - Auflösung:
  • 0,1 / 0,01 / 0,001
  • 0,1 / 0,01 / 0,001
  • pH - Genauigkeit:
  • ±0,002
  • ±0,002
  • pH - Kalibrierung:
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • mV - Bereich:
  • ±2000,0
  • ±2000,0
  • mV - Auflösung:
  • 0,1
  • 0,1
  • mV - Genauigkeit:
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • Leitfähigkeitsbereich:
  • 0,001 µS/cm - 3000 mS/cm
  • 0,001 µS/cm - 3000 mS/cm
  • Auflösung der Leitfähigkeit:
  • 0,001 μS minimum, auto ranging, up to 4 significant digits
  • 0,001 μS minimum, auto ranging, up to 4 significant digits
  • Genauigkeit der Leitfähigkeit:
  • 0,5% of reading ±1 digit > 3 μS, 0,5% of reading ±0,01 μS ≤ 3 μS
  • 0,5% of reading ±1 digit > 3 μS, 0,5% of reading ±0,01 μS ≤ 3 μS
  • Zellkonstante Leitfähigkeit:
  • 0,001 - 199,9 cm⁻¹
  • 0,001 - 199,9 cm⁻¹
  • Kalibrierung der Leitfähigkeit:
  • Up to 5 points
  • Up to 5 points
  • Spezifischer Widerstand - Bereich:
  • 2 Ω/cm - 100 MΩ/cm
  • 2 Ω/cm - 100 MΩ/cm
  • Spezifischer Widerstand - Genauigkeit:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • Resistivity resolution:
  • 1 ohm or 0,1 meg-ohm, auto ranging
  • 1 ohm or 0,1 meg-ohm, auto ranging
  • Salinität - Bereich:
  • 0,06 - 80,00 psu / 0,05 - 42,00 ppt
  • 0,06 - 80,00 psu / 0,05 - 42,00 ppt
  • Salinität - Auflösung:
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • Salinität - Genauigkeit:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • TDS - Bereich:
  • 0,001 - 200,0 ppm
  • 0,001 - 200,0 ppm
  • TDS - Auflösung:
  • 0,001 ppm minimum, auto ranging, up to 4 significant digits
  • 0,001 ppm minimum, auto ranging, up to 4 significant digits
  • TDS - Genauigkeit:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • Temperaturbereich:
  • –5,0...+105,0 °C
  • –5,0...+105,0 °C
  • Temperaturauflösung:
  • 0,1 °C
  • 0,1 °C
  • Temperaturgenauigkeit:
  • ±0,1 °C
  • ±0,1 °C
  • Temperatur - Kompensation:
  • Linear, non linear nLFn, non linear nLFu, EP (USP), off
  • Linear, non linear nLFn, non linear nLFu, EP (USP), off
  • Sensortyp:
  • DuraProbe 4-cell conductivity sensor
  • DuraProbe 4-cell conductivity sensor
  • Display:
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Batterielebensdauer:
  • 800 h
  • 800 h
  • Stromversorgung:
  • AC adapter or 4 AA batteries
  • AC adapter or 4 AA batteries
  • Konformität:
  • IP 54
  • IP 54
  • Operating temperature range:
  • 5...45 °C (ambient)
  • 5...45 °C (ambient)
  • Datenprotokollierung - Logfunktion:
  • Manual / Automatic with AUTO-READ™
  • Manual / Automatic with AUTO-READ™
  • Kapazität Datenprotokollierung:
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • Schutzklasse:
  • IP 54
  • IP 54
  • Anschlüsse:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
  • Ausgänge:
  • RS232, USB
  • RS232, USB
  • Eingang:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
  • Referenztemperatur:
  • 5 / 10 / 15 / 20 / 25 °C
  • 5 / 10 / 15 / 20 / 25 °C
  • Alarm:
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • Anzahl der Kanäle:
  • 2
  • 2
  • Kalibrierung:
  • pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option
  • pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option
  • Kalibrierpunkte:
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • B×T×H:
  • 240×180×110 mm
  • 240×180×110 mm
  • Gewicht:
  • 0,9 kg
  • 0,9 kg

Specifications