Sie haben gesucht nach: Antigen-Antikörper-Tests
Antigen-antibody tests rely on the fact that there is a specific antibody for each antigen, and so each one can be used to detect the presence of the other. These tests are usually performed on serum, but occasionally samples of other body fluids, tissue, or stool may be used. Different models of antigen-antibody tests are available for the isolation and differentiation of various strains of infectious diseases. Superior testing kits deliver efficient detection of multiple antigens.
Latextests
Supplier: THERMO FISHER DIAGNOSTICS
Antigen-Antikörper Tests, Streptex
Expand 27 Items
Bacterial antigen rapid latex agglutination test, Wellcogen™
Supplier: THERMO FISHER DIAGNOSTICS
Directly detect antigens present in human cerebrospinal fluid (CSF), serum, urine, or blood cultures using Thermo Scientific™ Wellcogen™ Bacterial Antigen Rapid Latex Agglutination Test.
Expand 8 Items
Latex tests
Supplier: LIOFILCHEM
Identification of the main pathogenic microorganisms directly from clinical specimens.
Expand 1 Items
Latex agglutination test, Wellcolex®
Supplier: THERMO FISHER DIAGNOSTICS
Wellcolex® Rapid Latex Agglutination test kits are designed for rapid and accurate identification of enteric bacteria, such as Salmonella, Shigella and E.coli. With its high positive and negative predictive values (PPV >98,7%) and results in less than three minutes, laboratories can use this rapid screening test to eliminate Salmonella-negative samples from further testing, reducing the number of samples requiring confirmatory testing.
Expand 4 Items
Latex-Kit zur Antikörperbestimmung
Supplier: LIOFILCHEM
Dieses Kit dient zur qualitativen und halbquantitativen Bestimmung von Treponema pallidum Antikörpern.
Expand 1 Items
Clostridium difficile toxoid A
Supplier: ENZO LIFE SCIENCES
Clostridium difficile toxoid A from Clostridium difficile, strain VPI10463 is a high potency toxin applicable to ELISA, antibody capture, cytotoxicity studies, immunogen and LINE assay.
Expand 1 Items
Latex tests, Dryspot
Supplier: THERMO FISHER DIAGNOSTICS
Dry latex test designed to demonstrate by slide agglutination strains possessing a serogroup antigen.
Expand 24 Items
Ag-AK, Immunofluorescence test, IMAGEN™
Supplier: THERMO FISHER DIAGNOSTICS
IMAGEN™ is a qualitative direct immunofluorescence test used for detection and confirmation of the presence of virus in cell culture or in clinical specimen.
Expand 8 Items
Lateral Flow Test für Campylobacter, Singlepath® Campylobacter
Supplier: Merck
Campylobacteriosis is an infection caused by Campylobacter, most commonly C. jejuni. It produces an inflammatory, sometimes bloody, diarrhea or dysentery, including cramps, fever and abdominal pain. The debilitating neurological disorder, Guillain-Barre Syndrome (GBS), as well as reactive arthritis have also been associated with recent infections with certain C. jejuni strains. C. lari and the emerging pathogen, C. upsaliensis, have also been reported in a small percentage of cases of human Campylobacter infection. Campylobacter spp. are highly infectious - as few as 500 bacteria can cause illness. There is an increasing demand for Campylobacter testing in food to meet regulations regarding Campylobacter levels in poultry. The majority of Campylobacter spp. are relatively metabolically inactive, making identification based on biochemical characteristics difficult. Currently, the most commonly used techniques to test food products for Campylobacter are traditional methods based on culture media. Innovative, rapid tests make screening for pathogenic organisms easier. The one-step format reduces the possibility of errors during handling.
Expand 1 Items
Lateral Flow Tests für Salmonellen, Singlepath® Salmonella
Supplier: Merck
Most individuals infected with Salmonella develop diarrhea, fever, and abdominal cramps 12 to 72 H after infection. The illness usually lasts 4 to 7 days, and the majority of patients recover without treatment. However, in some cases, the diarrhea may be so severe that hospitalisation is required. Salmonella is a genus of rod-shaped, Gram-negative, non spore-forming, predominantly motile bacteria, belonging to the Enterobacteriaceae family. Salmonella spp. are one of the most common causes of food poisoning worldwide and have been isolated from most types of raw food (e.g. meats, eggs and plant products). Their high resistance to drying combined with a very high heat resistance once dried makes Salmonella a potential problem in most foods, particularly in dry and semi-dry products. Food legislation in many countries includes limits on Salmonella – typically absence in 25 g of food. Traditional microbiological methods for detection of Salmonella in food and animal feed require a total of up to five days to obtain a simple yes/no result. Innovative, rapid tests make screening for pathogenic organisms easier. The one-step format reduces the possibility of errors during handling.
Expand 1 Items
Clostridium difficile toxin B
Supplier: ENZO LIFE SCIENCES
Clostridium difficile toxin B from Clostridium difficile, strain VPI10463 is a high purity toxin applicable to ELISA, antibody capture, cytotoxicity studies and LINE assay.
Expand 1 Items
Clostridium difficile toxin A
Supplier: ENZO LIFE SCIENCES
Clostridium difficile toxin A from Clostridium difficile, strain VPI10463 is a high potency toxin applicable to ELISA, antibody capture, cytotoxicity studies and LINE assay.
Expand 1 Items
Clostridium difficile toxoid B
Supplier: ENZO LIFE SCIENCES
Clostridium difficile toxoid A from Clostridium difficile, strain VPI10463 is a high potency toxin applicable to ELISA, antibody capture, cytotoxicity studies, immunogen and LINE assay.
Expand 1 Items
Bordetella pertussis toxin
Supplier: ENZO LIFE SCIENCES
Bordetella pertussis toxin (Islet-activating protein, PTX) from Bordetella pertussis, strain NCTC 10739. is a high purity toxin applicable to ELISA, antibody capture, cytotoxicity studies, LINE assay.
Expand 1 Items
Latex toxin detection kits, RPLA
Supplier: THERMO FISHER DIAGNOSTICS
The technique of reversed passive latex agglutination (RPLA) enables soluble antigen such as bacterial toxins to be detected in an agglutination assay. In a standard agglutination assay, soluble antibody reacts with particulate antigen such as bacterial cells. However, in a reversed agglutination assay the antibody, which is attached to particles, reacts with the soluble antigen. The particles (in this case, latex) do not themselves play a part in the reaction and they are therefore passive.
Expand 6 Items
Lateral Flow Test für E. coli, Singlepath® E. coli O157 und Duopath® Verotoxins
Supplier: Merck
EHEC kann lebensbedrohliche Krankheiten auslösen, insbesondere bei Menschen mit Immunschwäche, kleinen Kindern und älteren Menschen. Obwohl die häufigste Ursache von EHEC ist E. coli O157, andere Serotypen wie O26, O45, O103, O111, O121 und O145 sind ebenfalls relativ häufige Infektionsursachen. Typische Symptome sind starke Bauchschmerzen und Durchfall, der zunächst wässrig, aber oft blutig wird. E. coli sind gramnegative, nicht sporulierende, fakultativ anaerobe Bazillen. Unter den pathogenen E. coli haben in den letzten Jahren Verotoxin-bildende Stämme (STEC oder VTEC) an Bedeutung gewonnen. Die Gruppe der enterohämorrhagischen E. coli (EHEC) mit seinem hochpathogenen Serovar O157:H7-Stamm ist in dieser Hinsicht besonders interessant. Hauptansteckungsquellen sind kontaminierte, rohe oder unzureichend erhitzte Lebensmittel tierischen Ursprungs, wie Fleisch und Milchprodukte. Das Reservoir für EHEC ist der Darm von Wiederkäuern. Bei der Verarbeitung von Fleisch- und Milchprodukten können Mikroorganismen bei unzureichenden hygienischen Bedingungen in Lebensmittel gelangen. Der drastische Anstieg der Lebensmittelkontamination durch E. coli O157 erfordert zuverlässige und schnelle Nachweismethoden. Innovative Schnelltests erleichtern das Screening auf Krankheitserreger. Komplette Test-Sets zum Nachweis von Krankheitserregern und Toxinen. Das einstufige Format reduziert die Möglichkeit von Fehlern bei der Handhabung. Neben Tests auf die häufigste Infektionsursache wird E. coli O157, dort endet ein 24-Stunden-Screening-Protokoll für VTEC, einschließlich E. coli O104:H4, basierend auf Rapidcult™ E. coli-Anreicherung kombiniert mit dem Nachweis mit Duopath® Verotoxinen.
Expand 1 Items
Lateral Flow Test für Listeria, Singlepath® Listeria
Supplier: Merck
Listeria monocytogenes ist eines der am weitesten verbreiteten Lebensmittelpathogene der Welt und verantwortlich für schwere Infektionen bei immungeschwächten Personen, schwangeren Frauen und Neugeborenen. In Folge ist die Mortalitätsrate bei infizierten Personen hoch, trotz der relativ geringen Anzahl von Fällen weltweit. Listeria-Infektionen (Listeriose) können zu einer milden Gastroenteritis bis hin zu schweren Fällen von Sepsis, Meningitis, Enzephalitis sowie zu Fehlgeburten führen. Aufgrund der ubiquitären Verteilung von Listeria und ihrer Fähigkeit, sich auch bei Kühlschranktemperaturen (2 bis 8 °C) zu vermehren, bilden Lebensmittel eine der wichtigsten Infektionsquellen. Listerien sind eine Gattung von Gram-positiven, nicht sporenbildenden, stabförmigen Bakterien. Von den sechs bekannten Spezies der Gattung Listeria ist Listeria monocytogenes als Human- und Tierpathogen besonders hervorzuheben; L. ivanovii ist nur tierpathogen, während L. innocua, L. seeligeri, L. grayi und L. welshimeri als unbedenkliche Umweltbakterien gelten. Folglich schreibt das Lebensmittelgesetz in vielen Ländern strenge Beschränkungen für Listeria spp. oder Listeria monocytogenes vor. Bei der Durchführung von Risiko-bezogenen Qualitätskontrollen in Lebensmitteln sollten die Tests für L. monocytogenes und für die Gattung Listeria im Allgemeinen durchgeführt werden. Das Vorhandensein von Listerien – insbesondere von L. innocua – ist ein Indikator für kritische hygienische Bedingungen im Produktionsprozess. Innovative Schnelltests erleichtern das Screening auf pathogene Keime. Das Ein-Schritt-Format reduziert die Möglichkeit von Fehlern bei der Durchführung.
Expand 1 Items
Allergen lateral flow IIR
Supplier: HYSERVE
To detect allergen in highly processed foods by special extraction solution and unique antibody. This lateral-flow test is a high-performance qualitative assay.