LiChrolut® Polypropylene Extraction Columns, MilliporeSigma
For nonpolar extraction, choose RP-18, RP-18E (Endcapped), or CN (Cyano) columns.
Typical sample matrix: aqueous buffer solution. Typical sample substances: aromatic ring systems and compounds with alkyl chains. Typical elution solvent: acetonitrile, methanol, and ethyl acetate. Endcapped cartridges have a bonded phase that is reacted with trimethylchlorosilane to cover silanols not previously reacted with the initial bonding reagent. For polar extraction, choose CN (Cyano) or Si (Silica Gel) columns. Typical sample matrix: hexane, oils, and chlorinated hydrocarbons. Typical sample substances: hydroxyl groups, amines, and compounds with hetero-atoms (S, N, O). Typical elution solvent: methanol and 2-propanol.
For nonpolar extraction on a polymer phase, choose EN columns. Typical sample matrix: drinking water, ground water, surface water, and body fluids. Typical sample substances: polar contaminants, pesticides, phenols, explosives, anilines, and pharmaceuticals. Typical elution solvent: ethyl acetate, methanol, acetonitrile, and methanol (1:1).
For anion exchange extraction, choose NH₂ (weak) columns. Typical sample matrix: methanolic/aqueous buffer with low ionic strength, 2 pH units over pK value of the sample substance. Typical sample substances: anions, carboxylic acids, sulfonic acids, and phosphates. Typical elution solvent: aqueous buffer of high ionic strength (0.1 mol/L), 2 pH units over pK value of the sample substance.
For cation exchange extraction choose SCX (strong) columns. Typical sample matrix: methanolic/aqueous buffer with low ionic strength, 2 pH units under pK value of the sample substance. Typical sample substances: cations, amines, and pyrimidines. Typical elution solvent: aqueous buffer of high ionic strength (0.1 mol/L), 2 pH units over pK value of the sample substance.
For mixed mode extraction, choose TSC columns. Typical sample matrix: body fluids. Typical sample substances: cationic and neutral analytes. Typical elution solvent: chloroform-acetone, NH₃-ethyl-acetate, and NH₃-methanol.
: Sample preparation unit, drying unit and other accessories are sold separately.
For nonpolar extraction, choose RP-18, RP-18E (Endcapped), or CN (Cyano) columns.
Typical sample matrix: aqueous buffer solution. Typical sample substances: aromatic ring systems and compounds with alkyl chains. Typical elution solvent: acetonitrile, methanol, and ethyl acetate. Endcapped cartridges have a bonded phase that is reacted with trimethylchlorosilane to cover silanols not previously reacted with the initial bonding reagent. For polar extraction, choose CN (Cyano) or Si (Silica Gel) columns. Typical sample matrix: hexane, oils, and chlorinated hydrocarbons. Typical sample substances: hydroxyl groups, amines, and compounds with hetero-atoms (S, N, O). Typical elution solvent: methanol and 2-propanol.
For nonpolar extraction on a polymer phase, choose EN columns. Typical sample matrix: drinking water, ground water, surface water, and body fluids. Typical sample substances: polar contaminants, pesticides, phenols, explosives, anilines, and pharmaceuticals. Typical elution solvent: ethyl acetate, methanol, acetonitrile, and methanol (1:1).
For anion exchange extraction, choose NH₂ (weak) columns. Typical sample matrix: methanolic/aqueous buffer with low ionic strength, 2 pH units over pK value of the sample substance. Typical sample substances: anions, carboxylic acids, sulfonic acids, and phosphates. Typical elution solvent: aqueous buffer of high ionic strength (0.1 mol/L), 2 pH units over pK value of the sample substance.
For cation exchange extraction choose SCX (strong) columns. Typical sample matrix: methanolic/aqueous buffer with low ionic strength, 2 pH units under pK value of the sample substance. Typical sample substances: cations, amines, and pyrimidines. Typical elution solvent: aqueous buffer of high ionic strength (0.1 mol/L), 2 pH units over pK value of the sample substance.
For mixed mode extraction, choose TSC columns. Typical sample matrix: body fluids. Typical sample substances: cationic and neutral analytes. Typical elution solvent: chloroform-acetone, NH₃-ethyl-acetate, and NH₃-methanol.
: Sample preparation unit, drying unit and other accessories are sold separately.
Product Family Options
- DésignationPhaseGranulométrieCapacitéBed Weight
- LiChrolut® ENEN40 - 120 µm6 ml500 mg-: -
- LiChrolut® ENEN40 - 120 µm3 ml200 mg-: -
- LiChrolut® ENEN40 - 120 µm3 ml200 mg-: -
- LiChrolut® ENEN40 - 120 µm3 ml200 mg-: -
- LiChrolut® ENEN40 - 120 µm6 ml200 mg-: -
- LiChrolut® Florisil®Florisil150 - 250 µm6 ml1000 mgEach$607.95Case of 12$7,295.40: 1.19127.0001
- LiChrolut® RP18RP-1840 - 63 µm3 ml200 mg-: 1.02014.0001
- LiChrolut® RP18RP-1840 - 63 µm3 ml200 mgEach$687.13Case of 16$10,994.08: 1.02014.0001
- LiChrolut® RP18RP-1840 - 63 µm3 ml500 mgPack of 50$1,471.03: 1.02023.0001
- LiChrolut® RP18RP-1840 - 63 µm6 ml1000 mgEach$2,727.22Case of 14$38,181.08: 1.02122.0001
- LiChrolut® RP18RP-1840 - 63 µm6 ml500 mgEach$2,078.22Case of 12$24,938.64: 1.19687.0001
- LiChrolut® RP18RP-1840 - 63 µm1 ml100 mg-: 1.19855.0001
- LiChrolut® RP18RP-1840 - 63 µm1 ml100 mgPack of 100$1,639.09: 1.19855.0001
- LiChrolut® RP18ERP-18E40 - 63 µm3 ml200 mg-: 1.19847.0001
- LiChrolut® RP18ERP-18E40 - 63 µm3 ml200 mgPack of 50$1,531.79: 1.19847.0001
- LiChrolut® RP18ERP-18E40 - 63 µm3 ml500 mg-: 1.19849.0001
- LiChrolut® RP18ERP-18E40 - 63 µm3 ml500 mgPack of 50$2,496.51: 1.19849.0001
- LiChrolut® SCXSCX (Strong Cation Exchange)40 - 63 µm3 ml200 mg-: -
- LiChrolut® SCXSCX (Strong Cation Exchange)40 - 63 µm3 ml200 mg-: -
- LiChrolut® SCXSCX (Strong Cation Exchange)40 - 63 µm3 ml500 mg-: -
- LiChrolut® SCXSCX (Strong Cation Exchange)40 - 63 µm3 ml500 mg-: -
- LiChrolut® SiSi40 - 63 µm3 ml500 mg-: -
- LiChrolut® SiSi40 - 63 µm3 ml500 mg-: -
- LiChrolut® TSCTSC (Tox Screening Cation)40 - 63 µm3 ml300 mg-: -
- LiChrolut® TSCTSC (Tox Screening Cation)40 - 63 µm3 ml300 mg-: -
Accessories
- DescriptionDetails
- DescriptionDetails
- DescriptionDetails
- CA1.19852.0001Drying UnitDirects an inert gas through each of the 12 positions to dry the column packing before elutingEach - $6,202.57
Certains produits peuvent apparaître comme restreints
Pour garantir un passage en caisse fluide et rapide,veuillez-vous connecter à votre compte.Certains articles peuvent apparaître comme restreints simplement parce que vous n'êtes pas connecté.
Si vous n'avez pas de compte, vous pouvez vous inscrire en utilisant notre formulaire d'inscription en ligne (https://www.avantorsciences.com/ca/en/login/register)
Si des restrictions apparaissent toujours après votre connexion, certains produits — comme les produits chimiques ou les dispositifs médicaux — nécessitent des étapes supplémentaires de vérification de compte pour pouvoir passer une commande. Certains articles peuvent également nécessiter une licence spécifique ou une documentation supplémentaire ; la documentation requise sera demandée pour ces articles avant l’expédition.
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.