Order Entry
Canada
ContactUsLinkComponent
 
 
 
 
Méthanol ≥99.9% (by GC, corrected for water content), BAKER ANALYZED™ HPLC for liquid chromatography, for HPLC, UHPLC, for spectrophotometry, J.T.Baker®
    
    
 
undefined
 
 
 
Méthanol ≥99.9% (by GC, corrected for water content), BAKER ANALYZED™ HPLC for liquid chromatography, for HPLC, UHPLC, for spectrophotometry, J.T.Baker®
    
    
 

 

  • Environmentally Preferable:
    Safer Human and Environmental Health
  • Environmental certification:
    Chem21 Solvent selection guide recommended after discussion

 

 

  • Assay (CH₃OH) (by GC, corrected for water):
    = 99.8 %
  • Ultraviolet Absorbance (1.00-cm cell vs. water) - 400-254 nm:
    = 0.01
  • Ultraviolet Absorbance (1.00-cm cell vs. water) - 225 nm:
    = 0.15
  • Ultraviolet Absorbance (1.00-cm cell vs. water) - UV Cut-off, nm:
    = 205
  • Gradient Elution Test (a.u.) - 254 nm:
    = 0.002
  • Fluorescence Trace Impurities, measured as Quinine Base - at 450 nm Emission:
    = 0.3 ppb
  • Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities:
    = 1.0 ppb
  • Acetone:
    = 0.001 %
  • Residue after Evaporation:
    = 1 ppm
  • Titrable Acid (µeq/g):
    = 0.3
  • Titrable Base (µeq/g):
    = 0.1
  • Water (by KF, coulometric):
    = 0.05 %

 

 