80793 Resultaten voor: "Flame Ionization Detector (FID) Supplies"
Blower transition adapters
Supplier: LABCONCO
Epoxy-coated steel blower transition adapters fit all Labconco coated steel blowers.
Expand 2 Items
Elbows
Supplier: LABCONCO
PVC elbows 90° are compatible with thermoplastic duct.
Expand 3 Items
Thermoplastic duct
Supplier: LABCONCO
PVC exhaust duct is type one, unplasticised, schedule 40, lightweight, and corrosion-resistant.
Expand 3 Items
Flexible duct connections
Supplier: LABCONCO
Flexible duct connections reduce vibration between the blower and PVC ductwork.
Expand 2 Items
n-Pentaan ≥99.9% (by GC), Suprasolv® hypergrade for organic trace analysis, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionization detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 2 Items
Tolueen, SupraSolv® for GC-ECD/FID, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionization detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 3 Items
2,2,4-Trimethylpentane, SupraSolv® for GC-ECD/FID, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionization detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 2 Items
n-Hexaan, SupraSolv® for GC-ECD/FID, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionization detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 4 Items
Petroleum spirit, 40…60 °C, Suprasolv® hypergrade for organic trace analysis, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionization detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 2 Items
Accessories for flame ionization detector (FID), auto-ignite
Supplier: PerkinElmer
FID jet contact/spring
Expand 4 Items
Cyclohexaan, SupraSolv® for gas chromatography, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionisation detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 3 Items
Standard mixture of n-alkanes for system performance test
Supplier: Restek
These are reference mixtures for ISO/DIS 9377 (German H-53), a gas chromatography–flame ionization detection (GC-FID) method.
Expand 1 Items
Flame photometric detector (FPD) supplies
Supplier: Agilent
In 2005, Agilent released an improved FPD with minimum detectable levels (MDL) of 3,6 pg/s for sulphur and 60 fg/s for phosphorus. This is more than a five times improvement for sulphur.
Expand 7 Items
Methyleenchloride ≥99.8% stabilised, Suprasolv® hypergrade for GC-ECD/FID, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionisation Detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 4 Items
Aceton ≥99.8%, SupraSolv® for GC-ECD/FID, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionisation Detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 4 Items
Vlamionisatiedetector (FID)voorraden
Supplier: Agilent
Before ordering parts for FID maintenance, determine which type of FID is installed on your GC. The FID is available in two versions: Dedicated, capillary optimized: for capillary columns only. Adaptable: for packed or capillary columns.
Expand 29 Items
Ethylacetaat, SupraSolv® for GC-ECD/FID, Supelco®
Supplier: Merck
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionisation detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Expand 3 Items
Flame photometric detectors
Supplier: Agilent
FPD is designed with minimum detectable levels of 3,6 pg/s for sulfur and 60 fg/s for phosphorus.
Expand 8 Items
Hydrogen generator, Precision Hydrogen Trace 1200
Supplier: PEAK SCIENTIFIC
The Precision Hydrogen Trace 1200 generator is designed primarily for GC carrier gas use, and can also be used for detectors requiring hydrogen fuel gas such as FID and FPD. One generator is capable of supplying multiple GC instruments.
Expand 1 Items
Gas-clean filters
Supplier: PerkinElmer
The fuel gas triple kit is perfect for purifying carrier gas and flame ionisation detector (FID) fuel gases, removing oxygen, moisture and hydrocarbons from the carrier gas using the triple filter and removing both moisture and hydrocarbons from the fuel gas using the two combi filters. Using the combi filters for FID hydrogen and air will produce a stable baseline, improving overall reproducability and sensitivity.
Expand 3 Items
CrossLab supplies for waters HPLC systems
Supplier: Agilent
Long-life deuterium lamp, 2000 hours, Voor: 2487 dual wavelength absorbance detector/2488 multichannel absorbance detector/ACQUITY TUV detector/UPLC TUV detector
Expand 50 Items
Hydrogen generators, Precision SL 100
Supplier: PEAK SCIENTIFIC
The smallest hydrogen generator for GC-FID, Precision hydrogen SL has been developed to offer a streamlined laboratory-grade hydrogen gas solution for GC flame detectors at a purity of 99,9995%. Precision hydrogen SL is safe, simple to use, easy to maintain and takes up minimal bench space.
Expand 13 Items
Supplies for variable wavelength detector (VWD)
Supplier: Agilent
Repair Kit for semi-micro flow cell and RFID (6 mm, 5μl, 120bar), micro flow cell, RFID, (3 mm, 2μl, 120bar)
Expand 6 Items
Operating supplies
Supplier: VARIAN
The operating supplies set includes two 500 ml constant pressure bottle, a diluent bottle (1 L), a three-way SIPS tee piece assembly for SIPS-20, six SIPS pump tubings, a SIPS kit and ten pack SIPS pump bands.
Expand 2 Items
Hydrogen generator, Precision Hydrogen 1200
Supplier: PEAK SCIENTIFIC
The Precision Hydrogen 1200 is the first 1L+ Hydrogen generator and it is designed to produce hydrogen at a flow of 1200 ml with up to 99,9995% purity. Precision 1200 H₂ generator provides the gas needed for detectors requiring Hydrogen fuel gas, such as FID, NPD and SCD, and it can also support GC carrier gases. One generator is capable of supplying multiple detectors, and is available in various flow rates to ideally suit individual customers’ needs.
Expand 1 Items
Nitrogen and Sulphur chemiluminescence detectors supplies
Supplier: Agilent
Nitrogen Chemiluminescence Detector (NCD) is a nitrogen-specific detector that produces a linear and equimolar response to nitrogen compounds based on a chemiluminescent reaction of NO with ozone.