Saisie de commande
Belgium
Lien pour commandesContactUsLinkComponent
60 résultats pour "specimen mounts"

"specimen mounts"

60 Résultats
Trier par

Zinc Formalin Fixative

Supplier: SIGMA ALDRICH MICROSCOPY

Zinc formalin fixative is a non-precipitating fixative. This fixative is compatible with histochemical, immunochemical and special stains. It may be used with automated tissue processors and also in manual methods. The zinc chloride component of the formulation increases the rigidity of cellular components to withstand subsequent processing, sectioning and staining procedures. Tissue specimens initially fixed using 10% neutral buffered formalin solution may be post-fixed using the zinc formalin fixative.

Expand 1 Items
Chargement...
Invertebrates prepared slides

Invertebrates prepared slides

Supplier: LIEDER JOHANNES

This set of invertebrates includes representative specimen of protozoa, sponges, coelenterata, worms, arthropoda, insects, molluscs, echinoderms and Acraniata.

Expand 2 Items
Chargement...

VWR® PERTEX®, Milieu de montage

Supplier: KLINIPATH

PERTEX® est le milieu original de séchage rapide pour le montage et la conservation des spécimens de diapositives. Il est prouvé que PERTEX® n'affecte pas la forme, la structure ou la couleur de l'échantillon monté, même après des années de stockage. Une fine couche de PERTEX® suffit pour que le couvre-objet adhère à la lame de microscope.

Expand 1 Items
Chargement...

Epoxy Embedding Medium Kit

Supplier: SIGMA ALDRICH MICROSCOPY

The Epoxy Embedding Medium Kit is a very widely used embedding medium for electron microscopy. The embedding formulation originally published by Luft (1961) is excellent for both plant and animal tissues. Due to the low viscosity of the resin, it penetrates the tissue specimen faster than Araldite and other polymers. It hardens easily and uniformly at low temperatures with the addition of dodecenylsuccinic anhydride (DDSA), methyl nadic anhydride (MNA), and the accelerator 2,4,6-tris(dimethylaminomethyl)phenol (DMP-30). Slight shrinkage may occur during curing. This kit is useful for embedding a variety of tissues as a wide range of hardness can be obtained with this resin to suit a specific tissue type by using two different anhydride curing agents (DDSA and MNA).

Expand 1 Items
Chargement...
Milieux d'inclusion et de montage

Milieux d'inclusion et de montage

Supplier: Merck

La dureté et l'uniformité définies du matériau à découper sont des conditions vitales pour l'obtention d'une qualité de découpe homogène. Ces conditions peuvent être respectées à l'aide de diverses substances adaptées, telles que des paraffines, des résines, de la gélatine et de la celloïdine.

Expand 1 Items
Chargement...
Milieu de montage, Entellan® nouveau

Milieu de montage, Entellan® nouveau

Supplier: Merck

Le produit Entellan® nouveau est un milieu de montage pour colleuses de lamelles et est spécialement conçu pour les instruments à montage automatique disponibles dans le commerce qui fonctionnent avec colleuses de lamelles. Sa viscosité est comprise entre 250 et 600 mPas, le 1,00869 a une petite plage de viscosité. Cette gamme de viscosité étroite améliore et accélère l'application, étant donné que ni le débit du compte-goutte ni le volume ne doivent être réinitialisé après la première exécution avec un nouveau flacon du produit Entellan® nouveau.

Expand 2 Items
Chargement...
Desiccator cabinet, SICCO wall

Desiccator cabinet, SICCO wall

Supplier: Bohlender

Transparent PPMA cabinet with reinforced aluminium frame, unit has a door with a foam rubber gasket and magnetic strip. Designed for storing or drying humidity sensitive products using silica gel. The controlled environment inside the desiccator is ideal for storing reference materials, retained samples, metallographic specimens, tobacco and DNA-samples.

Expand 1 Items
Chargement...

Polink-2 Plus HRP Rabbit DAB Detection Kit

Supplier: OriGene

Polink-2 Plus HRP anti rabbit detection kit is the 3rd generation of polymer detection system. It uses rabbit antibody specific enhancer to help amplify the polymer enzyme conjugate reaction to achieve super sensitivity and specificity in immunohistochemistry staining. It produces consistent immunostaining outcomes on archival tissues and on difficult-to-work antibodies. User may need to further dilute primary antibody due to super sensitivity of Polink-2 Plus detection system. It is a biotin free system, therefore, overcomes the non-specific staining caused by streptavidin/biotin system due to endogenous biotin. Most commonly used specimens for this system are: frozen tissue, paraffin-embedded tissue, freshly prepared lymphocytes and fixed culture cells. Suitable for manual or autostain. Staining conditions need to be optimised by user.

Expand 1 Items
Chargement...

Milieu de montage Eukitt®

Supplier: SIGMA ALDRICH MICROSCOPY

Il s'agit d'un milieu de montage (qui contient 45% de résine acrylique et 55% de xylènes) utilisé en microscopie. Il s'agit d'un adhésif et d'un conservateur d'échantillon pouvant être utilisé manuellement et dans un équipement de collage de lamelles automatique. Adhésif et produit d'étanchéité à usage spécial pour une utilisation avec les matériaux en verre, non plastiques et d'autres matériaux non réactifs.

Expand 2 Items
Chargement...
VWR® Q path® Safesolv, Solvent Substitute

VWR® Q path® Safesolv, Solvent Substitute

Supplier: VWR Chemicals

Q Path® Safesolv est un substitut non dangereux du xylène ou du toluène. Il est compatible avec le milieu de montage Q Path® Safemount référence 00647520. Il est utilisé à la place du xylène, du toluène, du méthylecyclohexane ou d'autres solvants au cours des étapes de déshydratation des préparations histologiques, ainsi que pendant les phases de coloration et de montage de lamelles.

Expand 1 Items
Chargement...
Milieu de montage anhydre Neo-Mount®

Milieu de montage anhydre Neo-Mount®

Supplier: Merck

Les produits de montage anhydre, telles que Neo-Mount®, doivent être utilisés pour le montage permanent et le stockage à long terme d'échantillons. Les lames traitées dans les laboratoires d'anatomo-pathologie devant être stockées jusqu'à 10 ans, les résultats de coloration doivent être stables et une décoloration n'est pas acceptable. Le milieu de montage anhydre Neo-Mount® est un milieu de montage pour microscopie à la coloration extrêmement stable, fabriqué avec des solvants à base de mélanges d'hydrocarbures aliphatiques. Il contient un substitut non aromatique du xylène, par conséquent, Neo-Mount® doit être combiné exclusivement avec Neo-Clear®. Le Xylène doit être évité dans l'étape de montage, car il entraîne une opacification des lames et laisse des traces. En outre, en plaçant les lames déshydratée sur papier filtre pendant environ 1 minute avant montage, tout excès de Neo-Clear® peut être évité, étant donné que des bulles d'air peuvent apparaître sous la lamelle couvre-objet. La même condition préalable doit également être respectée lors du montage des échantillons à l'aide d'une machine de montage automatique ; dans ce cadre, le NEO-CLEAR® peut être éliminé de la façon la plus efficace par incubation des lames pendant une minute dans un portoir à lames vide.

Expand 2 Items
Chargement...
Sample tubes for stool, with screw cap

Sample tubes for stool, with screw cap

Supplier: BOETTGER PAUL

PP, translucent.

Expand 3 Items
Chargement...
Décalcifiants osseux, Osteomoll® et Osteosoft®

Décalcifiants osseux, Osteomoll® et Osteosoft®

Supplier: Merck

Les tissus durs comme les os ou les dents et tous les échantillons de tissus calcifiés comme les ponctions de moelle osseuse nécessitent un pré-traitement spécial avant le traitement de routine par un laboratoire histologique.

Expand 4 Items
Chargement...
Accessoires

Accessoires

Supplier: ZEISS

Accessoire pour microscope inversé, Axio Vert, Cadre de fixation pour lame, 76×26 mm

Expand 1 Items
Chargement...
Marqueur PAP PEN pour l'immunocoloration

Marqueur PAP PEN pour l'immunocoloration

Supplier: MUGEN

Le marqueur PAP PEN est conçu pour former une barrière hydrofuge lorsqu'un cercle est tracé autour d'un échantillon. La barrière du PAP PEN retient les antisérums dans la zone définie et veille à ce que seule la quantité d'anticorps nécessaire à une réaction soit utilisée.

Expand 1 Items
Chargement...
Cervical brushes, Cytotak™ Transwab®, labelled

Cervical brushes, Cytotak™ Transwab®, labelled

Supplier: MEDICAL WIRE EQUIPMENT

Nylon-bristle cytology sampling brushes for cervical smears.

Expand 1 Items
Chargement...