Order Entry
Belgium
ContactUsLinkComponent
236 résultats pour "Solid Phase Extraction"

236 Résultats pour : "Solid Phase Extraction"

Trier par

Solid phase extraction cartridges, Bond Elut™ LMS

Supplier: VARIAN

Bond Elut™ LMS polymeric sorbent lets you elute without having to add amine modifiers, buffers, or acids. The elimination of secondary interactions means that elution of analytes can be achieved with pure organic solvents or HPLC mobile phase-compatible solvent mixtures of low ionic strength. These characteristics are crucial to allow compatibility with LC/MS or other delicate analytical techniques.

Expand 6 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying

Supplier: VARIAN

Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.

Expand 5 Items
Chargement...
Solid phase extraction cartridges, Bond Elut™ C1

Solid phase extraction cartridges, Bond Elut™ C1

Supplier: VARIAN

Due to the methyl group and subsequent low carbon load, Bond Elut™ C1 is the least retentive of all alkyl group bonded phases for non-polar compounds. However, due to the extensive end capping of this sorbent to mask polar silanol activity, retention and elution of polar and multi-functional analytes can still be achieved. Typical applications include plasma, urine and aqueous samples.

Expand 3 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ PPL

Supplier: VARIAN

Bond Elut™ PPL is a styrene-divinylvenzene (SDVB) polymer that has been modified with a proprietary non-polar surface. PPL will retain even the most polar classes of analytes, including phenols. The large particle size allows ease of flow for viscous or particulate rich water samples, while the high surface area and strong hydrophobicity ensure reproducible extractions with high recoveries upon elution. Bond Elut™ PPL is suitable for EPA Method 528 ‘Determination of Phenols in Drinking Water by SPE and Capillary GC/MS’.

Expand 9 Items
Chargement...
GenFind V3 Reagent Kits

GenFind V3 Reagent Kits

Supplier: Beckman Coulter

This prep system kit isolates and purifies genomic DNA (gDNA) from whole blood. The kit is uses Solid Phase Reversible Immobilisation (SPRI) paramagnetic bead-based technology to effectively produce a high recovery of high quality DNA for downstream applications such as PCR.

Expand 1 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ NEXUS and NEXUS WCX

Supplier: VARIAN

Bond Elut™ NEXUS is an ultra-clean polymeric sorbent which has bi-modal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no pre-conditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine.

Based on the same base polymer technology, Bond Elut™ NEXUS WCX is a weak cation exchange sorbent that offers extra selectivity for analytes, such as quaternary ammonium drugs and anabolic steroids.

Expand 8 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ CH

Supplier: VARIAN

Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.

Expand 5 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ NH₂

Supplier: VARIAN

Bond Elut™ NH₂ is a weaker anion exchanger than sorbents such as SAX (a quaternary amine sorbent that is always charged) and is therefore a better choice for retention of very strong anions, such as sulfonic acids, which may retain irreversibly on a SAX sorbent. Similar to Diol and SI sorbents, Bond Elut™ NH₂ is excellent for the separation of structural isomers.

Expand 24 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ PBA

Supplier: VARIAN

PBA is a unique sorbent consisting of a phenylboronic acid covalently linked to a silica gel surface. Covalent processes result in a higher retention to the sorbent surface than other mechanisms, resulting in superior clean-up. The boronate group has a high specificity for cis-diol containing compounds such as catechols, nucleic acids, low molecular weight proteins and carbohydrates.

Expand 6 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ DEA

Supplier: VARIAN

Bond Elut™ DEA bears some resemblance to Bond Elut™ NH₂ in its properties but with a slightly lower capacity as an anion exchange sorbent. DEA has a moderately non-polar character due to the alkyl side chains on the amino functionality. These groups still afford a medium level of polarity, higher than C₈ but less polar than C₂ or CN-E.

Expand 11 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ PRS

Supplier: VARIAN

Bond Elut™ PRS is a strong cation exchange sorbent that is also relatively high in polarity. With no appreciable degree of hydrophobicity, in non-polar solvents, PRS is capable of polar and hydrogen bonding interactions. Due to the very low pKa of PRS, a high ionic strength eluent must be used, and so the use of PRS is recommended for weaker cationic species such as pyridinium compounds.

Expand 7 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ Plexa PCX

Supplier: VARIAN

Bond Elut™ Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut™ Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removes neutral and acidic interferences from the matrix, concentrates basic analytes and therefore improves sensitivity in the determination of basic compounds.

Expand 11 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ C8

Supplier: VARIAN

Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.

Expand 23 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ Diol

Supplier: VARIAN

Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.

Expand 6 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ PSA

Supplier: VARIAN

Bond Elut™ PSA is an alkylated amine sorbent that contains two different amino functionalities, one secondary and one primary. This gives a slightly higher pKa and ionic capacity compared to Bond Elut™ NH₂. The PSA functional group is a very effective bidentate ligand and is therefore an excellent sorbent for chelation applications. PSA has a significantly higher carbon load than most amino functional sorbents and thus is a better choice for polar compounds, which retain too strongly on Bond Elut™ NH₂.

Expand 8 Items
Chargement...
Collecteurs de bloc en verre HyperSep™

Collecteurs de bloc en verre HyperSep™

Supplier: Thermo Fisher Scientific

Les collecteurs de vide pour colonnes d'extraction en phase solide HyperSep™ facilitent le traitement des échantillons.

Expand 2 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ Plexa

Supplier: VARIAN

The water-wettable, hydroxylated exterior allows excellent flow, even with biological fluids. A gradient of polarity on the polymer surface shunts small analytes to the more hydrophobic centre of the polymer bead, where they are retained prior to the washing and elution steps. Plexa provides these performance enhancements due to a unique polymeric architecture with a non-retentive, hydroxylated, amide-free surface and a non-polar PS/DVB core for retaining small molecules.

Expand 11 Items
Chargement...

Solid phase extraction cartridges, Bond Elut™ SCX

Supplier: VARIAN

Bond Elut™ SCX is a strong cation exchanger with a very low pKa. Although the pKa is similar to Bond Elut™ PRS, the presence of the benzene ring in the functional group increases the potential for non-polar interactions. This non-polar characteristic becomes particularly important when conducting ion-exchange from aqueous systems, where selectivity towards compounds exhibiting cationic and non-polar character is seen.

Expand 24 Items
Chargement...
Solid phase extraction cartridges, Bond Elut™ C18

Solid phase extraction cartridges, Bond Elut™ C18

Supplier: VARIAN

Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.

Expand 43 Items
Chargement...
Colonnes d'extraction en phase solide HyperSep™ Hypercarb™

Colonnes d'extraction en phase solide HyperSep™ Hypercarb™

Supplier: Thermo Fisher Scientific

Plates, 100% carbone graphite poreux (PGC), avec sélectivité pour les composés structurellement similaires, permettant une séparation des composés à l'aide de solvants simples. Phase inversée hydrophobe ; phase normale d'adsorption ; rétention polaire.

Expand 7 Items
Chargement...
Colonnes d'extraction en phase solide HyperSep™ en silice

Colonnes d'extraction en phase solide HyperSep™ en silice

Supplier: Thermo Fisher Scientific

Utilisation d'un sorbant polaire pour retenir les analytes dans les matrices non polaires

Expand 12 Items
Chargement...

Cartouches pour l'extraction sur phase solide CHROMAFIX HR-X (M) poids minimum d'adsorbant : 130 mg paquet de 50 pièces 1 * 50 Pce

Supplier: MACHEREY-NAGEL

Cartouches pour l'extraction sur phase solide CHROMAFIX HR-X (M) poids minimum d'adsorbant : 130 mg paquet de 50 pièces 1 * 50 Pce

Expand 1 Items
Chargement...

Reference Book 1 * 25 Pce

Supplier: Restek

Reference Book 1 * 25 Pce

Expand 1 Items
Chargement...

Cartouches pour l'extraction sur phase solide CHROMAFIX HR-X (L) poids minimum d'adsorbant : 360 mg paquet de 50 pièces 1 * 50 Pce

Supplier: MACHEREY-NAGEL

Cartouches pour l'extraction sur phase solide CHROMAFIX HR-X (L) poids minimum d'adsorbant : 360 mg paquet de 50 pièces 1 * 50 Pce

Expand 1 Items
Chargement...

Reference Book 1 * 1 Pce

Supplier: Restek

Reference Book 1 * 1 Pce

Expand 1 Items
Chargement...

Cartouches pour l'extraction sur phase solide CHROMAFIX C18f (M) approx. poids d'adsorbant: 480 mg paquet de 50 pièces 1 * 50 Pce

Supplier: MACHEREY-NAGEL

Cartouches pour l'extraction sur phase solide CHROMAFIX C18f (M) approx. poids d'adsorbant: 480 mg paquet de 50 pièces 1 * 50 Pce

Expand 1 Items
Chargement...

[EN]SILICA SAX - BOX 30X 6 ML TUBES M 1 * 30 Pce

Supplier: Agilent

[EN]SILICA SAX - BOX 30X 6 ML TUBES M 1 * 30 Pce

Expand 1 Items
Chargement...

[EN]SILICA SAX - BOXX 1ML TUBES MG 1 * 100 Pce

Supplier: Agilent

[EN]SILICA SAX - BOXX 1ML TUBES MG 1 * 100 Pce

Expand 1 Items
Chargement...

[EN]C18 ENDCAPPED BOX 30X 6ML TUBESMG 1 * 30 Pce

Supplier: Agilent

[EN]C18 ENDCAPPED BOX 30X 6ML TUBESMG 1 * 30 Pce

Expand 1 Items
Chargement...

[EN]MIXED C8/SI-SCX BOXX 1ML TUBESMG 1 * 100 Pce

Supplier: Agilent

[EN]MIXED C8/SI-SCX BOXX 1ML TUBESMG 1 * 100 Pce

Expand 1 Items
Chargement...
Trier par
Recommended for You