1461 Results for: "HAMILTON BONADUZ"
pH buffers, DuraCal
Supplier: HAMILTON BONADUZ
For full information concerning health and safety data please contact Avantor or Hamilton directly.
Expand 17 Items
Électrodes de pH pour mètres Knick® Portamess®
Supplier: HAMILTON BONADUZ
Ces électrodes sont adaptées aux équipements KNICK® Portamess®. La tête de l'électrode crée un joint hermétique avec le tube de sockage Portamess®.
Expand 3 Items
Accessoires pour distributeurs et diluteurs, MICROLAB série 500
Supplier: HAMILTON BONADUZ
Seringue TLL, 25 ml, Microlab®
Expand 15 Items
Electrodes de pH, Single Pore Glass
Supplier: HAMILTON BONADUZ
Le concept Single Pore (pore unique) offre une lecture rapide, fiable et précise grâce à un système breveté et éprouvé permettant un contact optimal entre l'électrolyte et l'échantillon.
Expand 1 Items
Seringues Headspace HDHT pour échantillonneurs automatiques Headspace PAL COMBI–xt®
Supplier: HAMILTON BONADUZ
Ces seringues Headspace présentent un modèle de fixation d'aiguille unique sans colle associé à un piston High Dynamic (HD). Elles sont spécialement conçues pour les échantillonneurs automatiques Headspace PAL COMBI–xt®. Les aiguilles pour seringues Headspace classiques sont fixées au corps en verre de la seringue à l'aide d'une colle (ciment). Les problèmes couramment rencontrés sont les aiguilles qui se détachent ou les pics fantômes en raison d'une faible inertie chimique du ciment avec les solvants ou d'une résistance limitée à une température plus élevée. Ces problèmes sont résolus par l'utilisation de seringues Headspace haute température sans colle (HDHT).
Expand 6 Items
Colonnes HPLC d'échange cationique, HC-75
Supplier: HAMILTON BONADUZ
Les colonnes HC-75 séparent les composés par échange de ligands. Les différentes formes de HC-75 (hydrogène, calcium et plomb) offrent chacune une sélectivité unique pour séparer différents types d'analytes chargés en fonction de l'électronégativité du contre-ion.
Expand 13 Items
Seringues série 900 Microliter™
Supplier: HAMILTON BONADUZ
Les seringues série 900 représentent la version économique de la seringue série 800. Cette série de seringues est idéale pour la distribution de volumes compris entre 0,5 μl et 10 μl. Le porte-seringue est fixé de façon permanente sur le corps de la seringue, ce qui réduit le coût initial de la seringue, mais élimine la possibilité de remplacer des composants.
Expand 6 Items
Colonnes HPLC en phase inverse, HxSil C8 et C18
Supplier: HAMILTON BONADUZ
Colonnes de silice 100 Å pour séparations en phase inverse.
Expand 19 Items
Compression fittings
Supplier: HAMILTON BONADUZ
The compression fittings and adaptors are designed to connect Hamilton removable needle (RN) and knurled hub (KH) syringes to glass capillary tubing and PEEK tubing. The connectors can be combined in a variety of different configurations to meet most connection needs.
Expand 4 Items
Pointes de pipette, pointes ClickSure™
Supplier: HAMILTON BONADUZ
Ces pointes sont validées afin d'optimiser les performances du système Microlab 300, offrant une exactitude et une précision supérieures. Lorsque les pointes sont placées sur la sonde, le joint torique de la sonde s'insère dans la rainure de la pointe. Cette conception ne requiert qu'une faible force d'insertion pour charger correctement une pointe : l'utilisateur bénéficie alors d'une ergonomie accrue et d'une utilisation à long terme moins fatigante.
Expand 4 Items
Syringes for Shimadzu GC autosamplers
Supplier: HAMILTON BONADUZ
These syringes are used for GC autosamplers.
Expand 4 Items
Syringes for thin layer chromatography
Supplier: HAMILTON BONADUZ
The needle points of these thin layer chromatography syringes are covered with a PTFE coating which reduces the surface tension between the needle and the liquid making it ideal for reproducible sample spotting.
Expand 6 Items
Guide de seringues intégré
Supplier: HAMILTON BONADUZ
Le guide de seringues est fourni avec une seringue installée en usine. Ainsi, aucun montage n'est requis, évitant ainsi tout endommagement des seringues à plus petit volume. Ceci est particulièrement important pour les seringues de série 7000, dont les fils du piston sont extrêmement petits.
Expand 1 Items
Seringues, avec adaptateur Chaney intégré, Microliter™ et Gastight®
Supplier: HAMILTON BONADUZ
Seringue, chromatographie, Microliter™, HPLC/CPG, 7101 KHCH, Volume: 1 µl, Type de pointe: 3, Jauge: 22, Longueur: 70 mm, Cdt: 1
Expand 5 Items
Distributeur pour seringues, Microlab® 600
Supplier: HAMILTON BONADUZ
The Microlab® 600 dispensers are highly precise syringe pumps with a touchscreen graphical user interface designed to quickly and easily dispense liquids. This positive displacement system provides better than 99% accuracy, independent of liquid viscosity, vapour pressure and temperature. The inert fluid path minimises sample carry over and improves compatibility with harsh chemicals. There are three different dispenser models available.
Expand 8 Items
Syringes for Spark Holland HPLC autosamplers
Supplier: HAMILTON BONADUZ
This line of syringes developed for Spark Holland HPLC autosamplers offer everything required of an instrument syringe: chemical inertness, long life, reduced friction, precision and accuracy.
Expand 6 Items
Syringe cleaner
Supplier: HAMILTON BONADUZ
Specifically designed for rapidly cleaning 7000 series modified Microliter™ syringes, this syringe cleaner also effectively cleans Microliter™ and Gastight® syringes. A combination of heat (approximately 370 °C) and vacuum vaporises and extracts contaminants from the needle. The syringe cleaner is ineffective for septa-plugged needles, seised plungers and other irreparable needles.
Expand 2 Items
Colonnes HPLC d'échange anionique, RCX-30
Supplier: HAMILTON BONADUZ
Les colonnes RCX-30 pour l'analyse des hydrates de carbone sont conçues pour la séparation isocratique ou avec gradient des hydrates de carbone. Lorsqu'une méthode isocratique est utilisée avec une conductivité, un indice de réfraction, un détecteur à ultraviolets ou un détecteur ampérométrique à pulsation (PAD), les monosaccharides et disaccharides, comme le fructose, le glucose, le saccharose et le lactose peuvent être rapidement déterminés.
Expand 5 Items
Seringues série 600 Microliter™
Supplier: HAMILTON BONADUZ
Les seringues série 600 présentent une course de piston réduite de moitié par rapport aux seringues série 700. Cette série de seringues est idéale pour la distribution de volumes compris entre 0,25 μl et 5 μl. La série 600 est souvent utilisée pour les tâches à une seule main en raison de son piston renforcé à course réduite.
Expand 2 Items
Syringes for HPLC autosamplers, for WATERS® WISP™
Supplier: HAMILTON BONADUZ
These gas tight syringe are designed for HPLC autosamplers.
Expand 2 Items
Multi-channel pipettes, electronic, variable volume, SofTouch™
Supplier: HAMILTON BONADUZ
Electronic pipette for laboratory dispensing applications. The self-calibrating, microprocessor-based system reduces the possibility for human error and instrument contamination by controlling all piston movements.
Expand 2 Items
Replacement needles for Microlitre™ and Gastight® syringes
Supplier: HAMILTON BONADUZ
Needle, Aiguille de rechange avec large embout à rodage normalisé pour seringues 250 µl Microlitre™ et Gastight®, Jauge: 25s, Longueur: 50 mm, Type de pointe: 3
Expand 2 Items
SaltLine syringes
Supplier: HAMILTON BONADUZ
Seringue, chromatographie, C-XP-SAL, Volume: 5000 µl, Cdt: 1
Expand 18 Items
Électrodes de mesure d'oxygène dissous, OxyFerm FDA
Supplier: HAMILTON BONADUZ
Ces capteurs d'oxygène électrochimiques sont dédiés aux applications d'exigence élevée en termes d'hygiène (industrie pharmaceutique, biotechnologie, production d'aliments et de boissons). Ils sont équipés d'une membrane approuvée par la FDA pour une les processus d'hygiène. Ils sont capables de résister à la stérilisation à la vapeur, au processus d'autoclave et aux nettoyages en place.
Expand 10 Items
Colonnes HPLC d'échange anionique, PRP-X100
Supplier: HAMILTON BONADUZ
The PRP-X100 is a polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm. These columns can be used to separate ions at concentrations from 1 to 1000 ppm without suppression or elaborate preconcentration techniques. The highly inert polymeric support resists chemical attack from organic solvents and aqueous buffers (0 - 100% aqueous or organic; pH 1 to 13), effectively lengthening column life.
Expand 26 Items
Colonnes HPLC d'échange cationique, PRP-X400
Supplier: HAMILTON BONADUZ
Polymère d'échange cationique pour la séparation rapide du glyphosate et de ses métabolites dans l'eau potable.
Expand 12 Items
Disinfectant spray Kit, MICROLAB™
Supplier: HAMILTON BONADUZ
Ideal for the decontamination of DeCapper.
Expand 1 Items
Seringues pour injection GC "On-Column"
Supplier: HAMILTON BONADUZ
Seringues GC 'on-column' avec trois choix d'aiguilles: fixe acier inoxydable (N), amovible acier inoxydable (RN) ou amovible verre de silice (RNFS).
Expand 8 Items
Support pour chromatographie en phase inverse
Supplier: HAMILTON BONADUZ
Support pour chromatographie en phase inverse, silice et p-DSVB.
Expand 10 Items
Accessories for super syringes
Supplier: HAMILTON BONADUZ
TLL connector, Pour: super syringe S0500, S1000, S1500, S2000