Saisie de commande
Belgium
Lien pour commandesContactUsLinkComponent
 

HTD Equilibrium Dialysis Device

96 well equilibrium dialysis system, time to equilibrium 4 - 6 hours, 0,030 - 0,150 ml
N° de catalogue HTDL1009
Marketsource
Fournisseur:   HTDIALYSIS
HTD Equilibrium Dialysis Device
N° de catalogue HTDL1009
Fournisseur:  HTDIALYSIS
Marketsource
HTD Equilibrium Dialysis Device
HTD Equilibrium Dialysis Device

96 well equilibrium dialysis system, time to equilibrium 4 - 6 hours, 0,030 - 0,150 ml

Prix
Demander un prix
Connexion Pour la disponibilité
1 * 1 SET
Product Details & Documents

HTD reusable equilibrium dialysis device combines industry-leading accuracy and precision with an automation compatible design for a cost efficient, scalable solution.

  • Simultaneously process 1 to 96 assays, each with a 30 to 150 µl capacity to conserve valuable reagents
  • Compatible with a wide range of dialysis membrane pore sizes
  • Ready in minutes, achieves equilibrium in 4 to 6 hours on average
  • Automatable with standard robotic workstations and 96-well pipettors
  • Ready access to both the sample and dialysate sides of the membrane from the top of the device
  • Minimal non-specific binding due to 100% Teflon block construction
  • Reusable device is cost-effective, eco-friendly, and scalable
  • Compatible with a wide range of dialysis membrane pore sizes: 1 kDa, 3,5 kDa, 6 to 8 kDa, 10 kDa, 12 to 14 kDa, 25 kDa, 50 kDa

The HTD96B micro equilibrium device was developed at a Global Pharmaceutical Research laboratory to assess serum protein binding, microsomal protein binding, and tissue specific binding of drug candidates, conserving sample quantities, and achieving rapid equilibrium.

Reusable device combines industry-leading accuracy and precision with an automation compatible design for a scalable, cost-efficient, and eco-friendly solution.

Applications:
- Serum/plasma protein binding
- Microsome protein binding
- Relative binding of drug to specific tissues
- Receptor binding
- T3/T4 free fraction binding (hyperthyroidism) determinations

The 96C model has a shorter diffusion path with a 25 to 75 µl capacity and achieves equilibrium in 2 to 4 hours on average.

Additional specifications:
Dimensions: 170,1×116,8×38,1 mm
Weight: 0,54 kg

Spécifications
  • Volume:
    0,030 - 0,150 ml
  • Désignation:
    96 well equilibrium dialysis system, time to equilibrium 4 - 6 hours
  • Seq:
    02
Accessories

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • HTDL1005
    Equilibrium dialysis connecting rods
    Connexion Pour la disponibilité
    1 * 2 ST

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • HTDL1010
    96 well equilibrium dialysis teflon block (shorter diffusion path)
    Connexion Pour la disponibilité
    1 * 1 ST

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • HTDL1008-01
    Stainless steel springs
    Connexion Pour la disponibilité
    1 * 20 ST

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • HTDL1003
    96 well equilibrium dialysis Teflon block
    Connexion Pour la disponibilité
    1 * 1 ST

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • MSPP1007
    Equilibrium dialysis base clamp
    Connexion Pour la disponibilité
    1 * 1 ST

Informations sur le produit

  • N° de catalogue
    Désignation
    Disponibilité
    Prix
  • HTDL1008
    Stainless steel pressure plate
    Connexion Pour la disponibilité
    1 * 1 ST