Multi-parameter meter (pH/conductivity/oxygen), handheld, SensoDirect 150
À propos de cet article
The SensoDirect 150 is designed for multi purpose operation and measures pH/Redox, dissolved oxygen and conductivity/TDS.
- Data logger function, results can be downloaded to a PC for further analysis
- Automatic calibration + buffer recognition
- Large LCD display, intuitive user interface, HOLD function
- Flip out stand for bench top use
- Rugged protective casing for field use and built-in electrode holder for safe storage
Typical applications include: Drinking water, cooling/boiler water, waste water, pool water, surface water, water treatment companies, industrial and governmental laboratories.
Delivery information: Supplied with batteries, pH electrode, temperature probe, pH buffer set 4,00 / 7,00, instruction manual, guarantee sheet and sturdy case.
The pH / Con set additionally includes a conductivity probe.
The pH / Oxi set additionally includes an oxygen sensor, electrolyte, and membrane heads.
The pH / Con / Oxi set additionally includes a conductivity probe, an oxygen sensor, electrolyte, and membrane heads.
3 Options disponibles ci-dessous
Product Details & Documents
The SensoDirect 150 is designed for multi purpose operation and measures pH/Redox, dissolved oxygen and conductivity/TDS.
- Data logger function, results can be downloaded to a PC for further analysis
- Automatic calibration + buffer recognition
- Large LCD display, intuitive user interface, HOLD function
- Flip out stand for bench top use
- Rugged protective casing for field use and built-in electrode holder for safe storage
Typical applications include: Drinking water, cooling/boiler water, waste water, pool water, surface water, water treatment companies, industrial and governmental laboratories.
Delivery information: Supplied with batteries, pH electrode, temperature probe, pH buffer set 4,00 / 7,00, instruction manual, guarantee sheet and sturdy case.
The pH / Con set additionally includes a conductivity probe.
The pH / Oxi set additionally includes an oxygen sensor, electrolyte, and membrane heads.
The pH / Con / Oxi set additionally includes a conductivity probe, an oxygen sensor, electrolyte, and membrane heads.
Spécifications de la famille de produits
Spécifications
- Catalog No:
- LOVI724200
- LOVI724210
- LOVI724220
- Modèle:
- SensoDirect 150
- SensoDirect 150
- SensoDirect 150
- pH - Gamme:
- 0...14
- 0...14
- 0...14
- pH - Résolution:
- 0,01
- 0,01
- 0,01
- Précision - pH:
- ±0,02 + 2 chiffres
- ±0,02 + 2 chiffres
- ±0,02 + 2 chiffres
- pH - Étalonnage:
- Étalonnage en 3 points ; pH 7, pH 4 et pH 10
- Étalonnage en 3 points ; pH 7, pH 4 et pH 10
- Étalonnage en 3 points ; pH 7, pH 4 et pH 10
- mV - Gamme:
- ± 1999
- ± 1999
- ± 1999
- mV - Résolution:
- 1
- 1
- 1
- mV - Précision:
- ±0,5% + 2 chiffres
- ±0,5% + 2 chiffres
- ±0,5% + 2 chiffres
- Plage de conductivité:
- 0 - 200,0 µS / 0,2 - 2,000 mS / 2 - 20,00 mS / 20 - 200,00 mS
- 0 - 200,0 µS / 0,2 - 2,000 mS / 2 - 20,00 mS / 20 - 200,00 mS
- 0 - 200,0 µS/cm
0,2 - 2,000 mS
2 - 20,00 mS
20 - 200,00 mS/cm
- Résolution de conductivité:
- 0,1 µS (0 - 200,0 µS)
0,001 mS (0,2 - 2,000 mS)
0,01 mS (2 - 20,00 mS)
0,1 mS (20 - 200,00 mS) - 0,1 µS (0 - 200,0 µS)
0,001 mS (0,2 - 2,000 mS)
0,01 mS (2 - 20,00 mS)
0,1 mS (20 - 200,00 mS) - 0,1 µS (0 - 200,0 µS)
0,001 mS (0,2 - 2,000 mS)
0,01 mS (2 - 20,00 mS)
0,1 mS (20 - 200,00 mS)
- Précision de la conductivité:
- ± 2 % F.S. + 1 digit
- ± 2 % F.S. + 1 digit
- ± 2 % F.S. + 1 digit
- Température de référence de conductivité:
- 0 - 60 °C
- 0 - 60 °C
- 0 - 60 °C
- TDS - Gamme:
- 0 - 132 ppm
132 - 1,320 ppm
1,320 - 13,200 ppm
13,200 - 132,000 ppm - 0 - 132 ppm
132 - 1,320 ppm
1,320 - 13,200 ppm
13,200 - 132,000 ppm - 0 - 132 ppm
132 - 1,320 ppm
1,320 - 13,200 ppm
13,200 - 132,000 ppm
- TDS - Résolution:
- 0,1 ppm (0 - 132 ppm)
1 ppm (132 - 1,320 ppm)
10 ppm (1,320 - 13,200 ppm)
100 ppm (13,200 - 132,000 ppm) - 0,1 ppm (0 - 132 ppm)
1 ppm (132 - 1,320 ppm)
10 ppm (1,320 - 13,200 ppm)
100 ppm (13,200 - 132,000 ppm) - 0,1 ppm (0 - 132 ppm)
1 ppm (132 - 1,320 ppm)
10 ppm (1,320 - 13,200 ppm)
100 ppm (13,200 - 132,000 ppm)
- TDS - Précision:
- ±2,0% + 1 chiffre
- ±2,0% + 1 chiffre
- ±2,0% + 1 chiffre
- OD Concentration:
- 0 - 20,0 mg/L
- 0 - 20,0 mg/L
- 0 - 20,0 mg/L
- Oxygène dissous - Résolution:
- 0,1 % / 0,1 mg/L
- 0,1 % / 0,1 mg/L
- 0,1 % / 0,1 mg/L
- Oxygène dissous - saturation:
- 0 - 100,0 %
- 0 - 100,0 %
- 0 - 100,0 %
- OD Précision:
- ±0,4 mg/l ; ± 0,7%
- ±0,4 mg/l ; ± 0,7%
- ±0,4 mg/l ; ± 0,7%
- Gamme de température:
- 0...+60 °C
- 0...+60 °C
- 0...+60 °C
- Détermination dela température:
- 0,1 °C
- 0,1 °C
- 0,1 °C
- Exactitude de la températue:
- ± 0,8 °C
- ± 0,8 °C
- ± 0,8 °C
- Compensation de température:
- pH : automatique/manuel (0...+100 °C)
- pH : automatique/manuel (0...+100 °C)
- pH : automatique/manuel (0...+100 °C)
- Affichage:
- Grand écran LCD à réglage de contraste
- Grand écran LCD à réglage de contraste
- Grand écran LCD à réglage de contraste
- Alimentation:
- 4 batteries UM3 AA 1,5 V ou adaptateur CC 9 V
- 4 batteries UM3 AA 1,5 V ou adaptateur CC 9 V
- 4 batteries UM3 AA 1,5 V ou adaptateur CC 9 V
- Acquisition des données - Enregistrement:
- Automatic or manual
- Automatic or manual
- Automatic or manual
- Acquisition des données - Capacité:
- 16000 jeux de données
- 16000 jeux de données
- 16000 jeux de données
- Sorties:
- RS232
- RS232
- RS232
- L×P×H:
- 76×38×203 mm
- 76×38×203 mm
- 76×38×203 mm
- Poids:
- 0,39 kg (without protective covering)
- 0,39 kg (without protective covering)
- 0,39 kg (without protective covering)
Spécifications
Product Family Options
Informations sur le produit
- DésignationDisponibilitéPrix
- SensoDirect 150, kit pH/Con/TDS/Oxi, avec électrode pH, capteur d'oxygène, sonde de température et de conductivitéConnexion Pour la disponibilité1 * 1 ST903,00 €Spécifications :
Plus
Specifications
Cat. No.LOVI724200ModèleSensoDirect 150pH - Gamme0...14pH - Résolution0,01Précision - pH±0,02 + 2 chiffrespH - ÉtalonnageÉtalonnage en 3 points ; pH 7, pH 4 et pH 10mV - Gamme± 1999mV - Résolution1mV - Précision±0,5% + 2 chiffresPlage de conductivité0 - 200,0 µS / 0,2 - 2,000 mS / 2 - 20,00 mS / 20 - 200,00 mSRésolution de conductivité0,1 µS (0 - 200,0 µS)
0,001 mS (0,2 - 2,000 mS)
0,01 mS (2 - 20,00 mS)
0,1 mS (20 - 200,00 mS)Précision de la conductivité± 2 % F.S. + 1 digitTempérature de référence de conductivité0 - 60 °CTDS - Gamme0 - 132 ppm
132 - 1,320 ppm
1,320 - 13,200 ppm
13,200 - 132,000 ppmTDS - Résolution0,1 ppm (0 - 132 ppm)
1 ppm (132 - 1,320 ppm)
10 ppm (1,320 - 13,200 ppm)
100 ppm (13,200 - 132,000 ppm)TDS - Précision±2,0% + 1 chiffreOD Concentration0 - 20,0 mg/LOxygène dissous - Résolution0,1 % / 0,1 mg/LOxygène dissous - saturation0 - 100,0 %OD Précision±0,4 mg/l ; ± 0,7%Gamme de température0...+60 °CDétermination dela température0,1 °CExactitude de la températue± 0,8 °CCompensation de températurepH : automatique/manuel (0...+100 °C)AffichageGrand écran LCD à réglage de contrasteAlimentation4 batteries UM3 AA 1,5 V ou adaptateur CC 9 VAcquisition des données - EnregistrementAutomatic or manualAcquisition des données - Capacité16000 jeux de donnéesSortiesRS232L×P×H76×38×203 mmPoids0,39 kg (without protective covering) - SensoDirect 150, kit pH/Con/TDS, avec électrode pH, sonde de température et de conductivitéConnexion Pour la disponibilité1 * 1 ST784,00 €Spécifications :
Plus
Specifications
Cat. No.LOVI724210ModèleSensoDirect 150pH - Gamme0...14pH - Résolution0,01Précision - pH±0,02 + 2 chiffrespH - ÉtalonnageÉtalonnage en 3 points ; pH 7, pH 4 et pH 10mV - Gamme± 1999mV - Résolution1mV - Précision±0,5% + 2 chiffresPlage de conductivité0 - 200,0 µS / 0,2 - 2,000 mS / 2 - 20,00 mS / 20 - 200,00 mSRésolution de conductivité0,1 µS (0 - 200,0 µS)
0,001 mS (0,2 - 2,000 mS)
0,01 mS (2 - 20,00 mS)
0,1 mS (20 - 200,00 mS)Précision de la conductivité± 2 % F.S. + 1 digitTempérature de référence de conductivité0 - 60 °CTDS - Gamme0 - 132 ppm
132 - 1,320 ppm
1,320 - 13,200 ppm
13,200 - 132,000 ppmTDS - Résolution0,1 ppm (0 - 132 ppm)
1 ppm (132 - 1,320 ppm)
10 ppm (1,320 - 13,200 ppm)
100 ppm (13,200 - 132,000 ppm)TDS - Précision±2,0% + 1 chiffreOD Concentration0 - 20,0 mg/LOxygène dissous - Résolution0,1 % / 0,1 mg/LOxygène dissous - saturation0 - 100,0 %OD Précision±0,4 mg/l ; ± 0,7%Gamme de température0...+60 °CDétermination dela température0,1 °CExactitude de la températue± 0,8 °CCompensation de températurepH : automatique/manuel (0...+100 °C)AffichageGrand écran LCD à réglage de contrasteAlimentation4 batteries UM3 AA 1,5 V ou adaptateur CC 9 VAcquisition des données - EnregistrementAutomatic or manualAcquisition des données - Capacité16000 jeux de donnéesSortiesRS232L×P×H76×38×203 mmPoids0,39 kg (without protective covering) - SensoDirect 150, kit pH/Oxi, avec électrode pH, capteur d'oxygène et sonde de températureConnexion Pour la disponibilité1 * 1 ST823,00 €Spécifications :
Plus
Specifications
Cat. No.LOVI724220ModèleSensoDirect 150pH - Gamme0...14pH - Résolution0,01Précision - pH±0,02 + 2 chiffrespH - ÉtalonnageÉtalonnage en 3 points ; pH 7, pH 4 et pH 10mV - Gamme± 1999mV - Résolution1mV - Précision±0,5% + 2 chiffresPlage de conductivité0 - 200,0 µS/cm
0,2 - 2,000 mS
2 - 20,00 mS
20 - 200,00 mS/cmRésolution de conductivité0,1 µS (0 - 200,0 µS)
0,001 mS (0,2 - 2,000 mS)
0,01 mS (2 - 20,00 mS)
0,1 mS (20 - 200,00 mS)Précision de la conductivité± 2 % F.S. + 1 digitTempérature de référence de conductivité0 - 60 °CTDS - Gamme0 - 132 ppm
132 - 1,320 ppm
1,320 - 13,200 ppm
13,200 - 132,000 ppmTDS - Résolution0,1 ppm (0 - 132 ppm)
1 ppm (132 - 1,320 ppm)
10 ppm (1,320 - 13,200 ppm)
100 ppm (13,200 - 132,000 ppm)TDS - Précision±2,0% + 1 chiffreOD Concentration0 - 20,0 mg/LOxygène dissous - Résolution0,1 % / 0,1 mg/LOxygène dissous - saturation0 - 100,0 %OD Précision±0,4 mg/l ; ± 0,7%Gamme de température0...+60 °CDétermination dela température0,1 °CExactitude de la températue± 0,8 °CCompensation de températurepH : automatique/manuel (0...+100 °C)AffichageGrand écran LCD à réglage de contrasteAlimentation4 batteries UM3 AA 1,5 V ou adaptateur CC 9 VAcquisition des données - EnregistrementAutomatic or manualAcquisition des données - Capacité16000 jeux de donnéesSortiesRS232L×P×H76×38×203 mmPoids0,39 kg (without protective covering)
Accessories
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
- LOVI724470Électrolyte de rechange pour capteur d'oxygèneConnexion Pour la disponibilité1 * 50 mL - 21,10 €
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
- LOVI724460Membrane de rechange pour capteur d'oxygèneConnexion Pour la disponibilité1 * 2 ST - 34,60 €
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
- LOVI724420Sonde de température PT1000, fournie avec un câble d'env. 1,5 mConnexion Pour la disponibilité1 * 1 ST - 50,00 €
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
- LOVI724410Capteur d'oxygène, fourni avec un câble d'env. 4 mConnexion Pour la disponibilité1 * 1 ST - 198,00 €
Informations sur le produit
- N° de catalogueDésignationDisponibilitéPrix
- LOVI724400Sonde de conductivité (Con/TDS), fournie avec un câble d'env. 1,2 mConnexion Pour la disponibilité1 * 1 ST - 81,20 €