The VACUU·SELECT complete controller is ready for use with existing vacuum sources like pumps or vacuum networks.
- Pre-defined vacuum applications and automatic boiling point detection saves time
- Simple set-up - connect VACUU·SELECT in-line between pump and vacuum application
- Integrated vent valve allows inert gas connection
- Integrated check valve minimises interaction with other applications on the same vacuum supply
The intuitive touch screen display offers pre-defined tools for all common vacuum processes. In evaporative processes, the first vapour pressure is detected then the controller uses a 2-point control to maintain a stable vacuum. With several other applications included, and the ability to adjust or customise processes to your needs, VACUU·SELECT covers a wide range of lab vacuum applications.
Use manual set-point control for simple processes, run pre-defined applications at the touch of a button, or create your own application with simple 'drag-and-drop' editing.
The controller is available as a bench top unit, ready for mounting on lab scaffolding, or as a built-in version for lab case work.
Livraison: Vacuum controller VACUU.SELECT supplied with solenoid valve, non return valve, integrated ceramic diaphragm vacuum sensor, venting valve, power supply, ready for use, with operating manual.
3 Options disponibles ci-dessous
Product Details & Documents
The VACUU·SELECT complete controller is ready for use with existing vacuum sources like pumps or vacuum networks.
- Pre-defined vacuum applications and automatic boiling point detection saves time
- Simple set-up - connect VACUU·SELECT in-line between pump and vacuum application
- Integrated vent valve allows inert gas connection
- Integrated check valve minimises interaction with other applications on the same vacuum supply
The intuitive touch screen display offers pre-defined tools for all common vacuum processes. In evaporative processes, the first vapour pressure is detected then the controller uses a 2-point control to maintain a stable vacuum. With several other applications included, and the ability to adjust or customise processes to your needs, VACUU·SELECT covers a wide range of lab vacuum applications.
Use manual set-point control for simple processes, run pre-defined applications at the touch of a button, or create your own application with simple 'drag-and-drop' editing.
The controller is available as a bench top unit, ready for mounting on lab scaffolding, or as a built-in version for lab case work.
Livraison: Vacuum controller VACUU.SELECT supplied with solenoid valve, non return valve, integrated ceramic diaphragm vacuum sensor, venting valve, power supply, ready for use, with operating manual.
Spécifications de la famille de produits
Spécifications
- Catalog No:
- 131-0006
- 131-0007
- 131-0005
- Modèle:
- VACUU·SELECT complete controller bench top device
- VACUU·SELECT complete controller for scaffold mounting
- VACUU·SELECT complete controller build-in version
- Fonctionnement normal:
- 1080 - 0,1 mbar (810 - 0,1 torr)
- 1080 - 0,1 mbar (810 - 0,1 torr)
- 1080 - 0,1 mbar (810 - 0,1 torr)
- Principe de mesure:
- Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
- Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
- Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
- Précision de mesure:
- <±1 mbar/hPa/torr / ±1 digit (after adjustment, constant temperature)
- <±1 mbar/hPa/torr / ±1 digit (after adjustment, constant temperature)
- <±1 mbar/hPa/torr / ±1 digit (after adjustment, constant temperature)
- Gamme de mesure:
- 1080 - 0,1 mbar (810 - 0,1 Torr)
- 1080 - 0,1 mbar (810 - 0,1 Torr)
- 1080 - 0,1 mbar (810 - 0,1 Torr)
- Coefficient de température:
- <0,15 mbar/hPa (<±0,11 Torr/K)
- <0,15 mbar/hPa (<±0,11 Torr/K)
- <0,15 mbar/hPa (<±0,11 Torr/K)
- Vanne d'entrée d'air (intégrée):
- Hose nozzle DN 4 - 5 mm
- Hose nozzle DN 4 - 5 mm
- Hose nozzle DN 4 - 5 mm
- Alimentation:
- 100 - 230 V, 50 - 60 Hz
- 100 - 230 V, 50 - 60 Hz
- 100 - 230 V, 50 - 60 Hz
- Consommation max. secteur:
- 4 A
- 4 A
- 4 A
- Indice de protection:
- IP 42/IP 40
- IP 42/IP 40
- IP 40/IP 41
- L×P×H:
- 191×127×187 mm
- 152×127×189 mm
- 152×126×108 mm
- Poids sans alimentation:
- 2,0 kg
- 2,0 kg
- 1,3 kg
Spécifications
Product Family Options
Informations sur le produit
- DésignationDisponibilitéPrix
- VACUU·SELECT complete controller bench top deviceConnexion Pour la disponibilité1 * 1 ST2 530,00 €Spécifications :
Plus
Specifications
Cat. No.131-0006ModèleVACUU·SELECT complete controller bench top deviceFonctionnement normal1080 - 0,1 mbar (810 - 0,1 torr)Principe de mesureCeramic diaphragm (alumina), capacitive, gas indep., absolute pressurePrécision de mesure<±1 mbar/hPa/torr / ±1 digit (after adjustment, constant temperature)Gamme de mesure1080 - 0,1 mbar (810 - 0,1 Torr)Coefficient de température<0,15 mbar/hPa (<±0,11 Torr/K)Vanne d'entrée d'air (intégrée)Hose nozzle DN 4 - 5 mmAlimentation100 - 230 V, 50 - 60 HzConsommation max. secteur4 AIndice de protectionIP 42/IP 40L×P×H191×127×187 mmPoids sans alimentation2,0 kg - VACUU·SELECT complete controller for scaffold mountingConnexion Pour la disponibilité1 * 1 ST2 530,00 €Spécifications :
Plus
Specifications
Cat. No.131-0007ModèleVACUU·SELECT complete controller for scaffold mountingFonctionnement normal1080 - 0,1 mbar (810 - 0,1 torr)Principe de mesureCeramic diaphragm (alumina), capacitive, gas indep., absolute pressurePrécision de mesure<±1 mbar/hPa/torr / ±1 digit (after adjustment, constant temperature)Gamme de mesure1080 - 0,1 mbar (810 - 0,1 Torr)Coefficient de température<0,15 mbar/hPa (<±0,11 Torr/K)Vanne d'entrée d'air (intégrée)Hose nozzle DN 4 - 5 mmAlimentation100 - 230 V, 50 - 60 HzConsommation max. secteur4 AIndice de protectionIP 42/IP 40L×P×H152×127×189 mmPoids sans alimentation2,0 kg - Spécifications :
Plus
Specifications
Cat. No.131-0005ModèleVACUU·SELECT complete controller build-in versionFonctionnement normal1080 - 0,1 mbar (810 - 0,1 torr)Principe de mesureCeramic diaphragm (alumina), capacitive, gas indep., absolute pressurePrécision de mesure<±1 mbar/hPa/torr / ±1 digit (after adjustment, constant temperature)Gamme de mesure1080 - 0,1 mbar (810 - 0,1 Torr)Coefficient de température<0,15 mbar/hPa (<±0,11 Torr/K)Vanne d'entrée d'air (intégrée)Hose nozzle DN 4 - 5 mmAlimentation100 - 230 V, 50 - 60 HzConsommation max. secteur4 AIndice de protectionIP 40/IP 41L×P×H152×126×108 mmPoids sans alimentation1,3 kg
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.