Vous avez recherché : Filtres à gaz

Filtres à gaz

Gas filters are used for purifying inert carrier gases for use in gas chromatography and anaerobic experiments. These filters can be either disposable or refillable. Desiccants and molecular sieves are utilized in removing water, oil, oxygen, hydrocarbons, and other contaminants that can damage chromatography columns. High-purity output due to a packed, extremely high surface area ensures ultra-pure gas, and filters are easy to replace for low maintenance.

Molecular sieve S-trap

Molecular sieve S-trap

Supplier: Restek

This molecular sieve S-trap is suitable for traping water vapour and also increases column and oxygen trap lifetime.

Expand 1 Items
Chargement...
High-capacity moisture traps

High-capacity moisture traps

Supplier: Restek

These high-capacity moisture traps are purged with ultra-high-purity helium and are ready to be used with any carrier gas including hydrogen.

Expand 2 Items
Chargement...

Click-On In-Line Super Clean® Replacement Gas Traps

Supplier: Restek

Super-clean click-on traps measure to be 21,6×3,2 cm (8,5×1,25").

Expand 2 Items
Chargement...

Fluosorber filter cannister

Supplier: HARVARD APPARATUS

Activated charcoal canister that is designed to optimise halogenated gas absorption. Fluosorber is factory tested with an air flow of 60 LPM to ensure resistance is not above 2 cm H₂O.

Expand 1 Items
Chargement...
Hydrocarbon trap

Hydrocarbon trap

Supplier: Restek

Hydrocarbon trap removes trace impurities from carrier gas. A 60 μm frit prevents gas contamination by purifier particles.

Expand 2 Items
Chargement...
Gas trapping systems for LC/MS, Super Clean®

Gas trapping systems for LC/MS, Super Clean®

Supplier: Restek

The Super Clean® gas trapping system purifies nitrogen and is ideal for use in LC-MS systems. The two position base plate (installed in the gas line; standard base plate inlet/outlet fittings accept ¹/₄" tubing) allows cartridges to be exchanged without introducing impurities into the system. To meet the high flow needs of the LC-MS system, the activated charcoal filled cartridges are positioned and connected in parallel.

Expand 1 Items
Chargement...
ECD vent trap

ECD vent trap

Supplier: Restek

This trap reduces the release of hazardous materials from the ECD vent into the lab.

Expand 1 Items
Chargement...
High-capacity oxygen trap

High-capacity oxygen trap

Supplier: Restek

These high-capacity oxygen trap removes up to 135 ml of oxygen or 2 g of water.

Expand 2 Items
Chargement...

Gas-clean filters

Supplier: PerkinElmer

The fuel gas triple kit is perfect for purifying carrier gas and flame ionisation detector (FID) fuel gases, removing oxygen, moisture and hydrocarbons from the carrier gas using the triple filter and removing both moisture and hydrocarbons from the fuel gas using the two combi filters. Using the combi filters for FID hydrogen and air will produce a stable baseline, improving overall reproducability and sensitivity.

Expand 3 Items
Chargement...
Gas-specific purifier modules, VICI® Mat/Sen®

Gas-specific purifier modules, VICI® Mat/Sen®

Supplier: Restek

These gas-specific purifier modules are optimised by incorporating a multiple-bed format that progressively lowers concentrations of contaminants at each successive bed. Replace separate oxygen, moisture and hydrocarbon traps with one multiple-bed purifier, specific for purifying helium, hydrogen, nitrogen or air.

Expand 8 Items
Chargement...