"WATERS"
Analytical HPLC columns, SymmetryShield™ RP18
Supplier: WATERS
SymmetryShield™ columns feature Waters' patented embedded polar group technology that shields the silica's residual silanols from highly basic analytes at improves overall peak shape. Additionally, by placing the embedded polar group close to the silica surface, the activity of the surface silanols is further reduced. This imparts selectivity and retention that is different compared to the Symmetry® C18 ligand.
Expand 7 Items
Solid phase extraction cartridges, Oasis® WAX
Supplier: WATERS
These Oasis® WAX cartridges contain the WAX sorbent, which is a polymeric reversed phase, weak anion exchange mixed mode sorbent that has been optimised for fast, simple, and highly selective sample preparation of strong acidic compounds.
Expand 1 Items
Gel permeation chromatography clean-up columns, Envirogel™
Supplier: WATERS
The Envirogel™ High-Resolution GPC cleanup columns are specifically designed to remove low volatility, high molecular weight interferences such as lipids and natural resins from environmental samples as specified in EPA method 3640A.
Expand 1 Items
SPE cartridge, Sep-Pak®
Supplier: WATERS
Specially designed for analysing formaldehyde, other aldehydes and ketones in air.
Expand 1 Items
Glycan BEH amide columns, ACQUITY UPLC™
Supplier: WATERS
The ACQUITY UPLC BEH glycan separation technology column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.
Expand 3 Items
Analytical HPLC columns, XTerra® Phenyl
Supplier: WATERS
XTerra® Phenyl columns are hybrid-based, reversed phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.
Expand 1 Items
Columns, ACQUITY UPLC™ HSS T3
Supplier: WATERS
An universal, silica based bonded phase with ACQUITY HSS T3 sorbents which is used for the separations for polar and non-polar compounds. It is compatibility with 100% of aqueous mobile phase. It exhibit ultra-low MS bleed, scalable and transferable to HPLC separations.
Expand 1 Items
UPLC columns, ACQUITY UPLC™ BEH C18
Supplier: WATERS
These columns are suitable for a diverse range of analytes. With mobile phase (pH 1 to 12) and temperature (80 °C) compatibility, this trifunctionally-bonded alkyl column is a universal method development tool that can impact the retention, selectivity and sensitivity of ionisable compounds (with mobile phase pH) while delivering low- and high-pH stability for all analyte types.
Expand 6 Items
Solid phase extraction cartridges, Sep-Pak® Vac
Supplier: WATERS
These cartridges deliver the option of minimum sample preparation. Consists of moulded, high purity PP syringe-barrel bodies with two PE frits to contain the packing material.
Expand 9 Items
Analytical HPLC columns, Symmetry® C18
Supplier: WATERS
Symmetry® C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactivated silica.
Expand 13 Items
Gel permeation chromatography columns, Styragel® HR
Supplier: WATERS
Styragel® HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterising samples in the low to mid molecular range where high resolution is critical.
Expand 7 Items
Sentry guard cartridges, XBridge™
Supplier: WATERS
XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1 to 12). The trifunctionally bonded C18 ligand provides with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed. The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent.
Expand 5 Items
Analytical HPLC columns, XSelect™ CSH C18
Supplier: WATERS
XSelect™ CSH C18 is a general purpose column that provides alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps to overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed and slow mobile-phase re-equilibration.
Expand 2 Items
Analytical HPLC columns, Symmetry® C8
Supplier: WATERS
Symmetry® C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactivated silica.
Expand 5 Items
Analytical HPLC columns, XTerra® MS C18
Supplier: WATERS
XTerra® MS C18 columns are general purpose, hybrid-based, reversed phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.
Expand 9 Items
Columns, ACQUITY UPLC™ CSH C18
Supplier: WATERS
ACQUITY UPLC method validation kit includes three batches of chromatographic media (derived from different base particles) to judge the quality, reliability, and consistency of the chromatographic method.
Expand 3 Items
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.