Optical dissolved oxygen (DO) measurement with IQ Sensor Net
About this item
A fluorescence optical method that delivers higher accuracy and better resolution measurement than by electrochemical methods. Intelligent membrane with IQMC technology means each membrane is individually calibrated and data stored in a memo chip permanently fixed to the membrane.
- Highest accuracy through the whole lifetime of sensor
- Coherent calibration C2 method
- High stability and minimum drift
- Soft Green Light technology prevents early bleaching of the dye in the membrane
- Suitable for low flow/no flow applications
2 Options Available Below
Product Details & Documents
A fluorescence optical method that delivers higher accuracy and better resolution measurement than by electrochemical methods. Intelligent membrane with IQMC technology means each membrane is individually calibrated and data stored in a memo chip permanently fixed to the membrane.
- Highest accuracy through the whole lifetime of sensor
- Coherent calibration C2 method
- High stability and minimum drift
- Soft Green Light technology prevents early bleaching of the dye in the membrane
- Suitable for low flow/no flow applications
Specifications for Product Family
Specifications
- Catalog No:
- 706-0524
- 706-0525
- Model:
- FDO 700 IQ
- FDO 700 IQ SW
- Min. flow rate:
- No flow required
- No flow required
- Response time:
- <150 s
- <60 s
- DO concentration:
- 0...20,00 mg/l
- 0...20,00 mg/l
- DO saturation:
- 0...200,0%
- 0...200,0%
- DO barometric pressure range:
- 10 bar
- 10 bar
- DO accuracy:
- ±0,05 mg/l
- ±0,05 mg/l
- DO resolution:
- 0,01 mg/l
- 0,01 mg/l
Specifications
Product Family Options
Product Information
- TypeAvailabilityPrice
- 706-0524FDO 700 IQ Optical, digital DO sensor suitable for water applications, without SACIQ cableFDO 700 IQ Optical, digital DO sensor suitable for water applications, without SACIQ cableFDO 700 IQ OpticalLog in for availability1 * 1 ST2 260,00 €Specifications:
More
Specifications
Cat. No.706-0524ModelFDO 700 IQMin. flow rateNo flow requiredResponse time<150 sDO concentration0...20,00 mg/lDO saturation0...200,0%DO barometric pressure range10 barDO accuracy±0,05 mg/lDO resolution0,01 mg/l - 706-0525FDO 700 IQ SW Optical, digital DO sensor specially suitable for salt water applications, without SACIQ cableFDO 700 IQ SW Optical, digital DO sensor specially suitable for salt water applications, without SACIQ cableFDO 700 IQ SW OpticalLog in for availability1 * 1 ST2 570,00 €Specifications:
More
Specifications
Cat. No.706-0525ModelFDO 700 IQ SWMin. flow rateNo flow requiredResponse time<60 sDO concentration0...20,00 mg/lDO saturation0...200,0%DO barometric pressure range10 barDO accuracy±0,05 mg/lDO resolution0,01 mg/l
Accessories
Product Information
- Catalog #AvailabilityPrice
- Hood for protection against fish
Product Information
- Catalog #AvailabilityPrice
- SACIQ-7,0 cable for all IQ sensors with IP68 waterproof connection to the IQ Sensor Net system, 7 mSACIQ-7,0 cable for all IQ sensors with IP68 waterproof connection to the IQ Sensor Net system, 7 m708-0048Log in for availability1 * 1 ST - 226,00 €
Product Information
- Catalog #AvailabilityPrice
- SACIQ-25.0 SW, IQ sensor connection cable, 25 m (seawater version)SACIQ-25.0 SW, IQ sensor connection cable, 25 m (seawater version)706-0064Log in for availability1 * 1 ST - 432,00 €
Product Information
- Catalog #AvailabilityPrice
- SC-FDO 700 Sensor cap for FDO® 700 IQ (SW)
Product Information
- Catalog #AvailabilityPrice
- IQ CH Cleaning head with tube (15 m)
Product Information
- Catalog #AvailabilityPrice
- Adapter for mounting IQ sensor FDO® 700 IQ in flow-thru vessels EBS 700-DU/N, EBST 700-DU/N and ESS 700 VA/NAdapter for mounting IQ sensor FDO® 700 IQ in flow-thru vessels EBS 700-DU/N, EBST 700-DU/N and ESS 700 VA/NWTWA203789Log in for availability1 * 1 ST - 659,00 €
Les recommandations seront personnalisées en fonction de vos préférences d’achat uniquement si vous avez donné votre consentement en activant l’option " Améliorer mon expérience d’achat " sur la page "Mon compte".
Dans le cas contraire, vous recevrez des recommandations génériques.