Calorimeters, C 6000 global standards and isoperibol packages
: IKA
The C 6000 global standards and C 6000 isoperibol calorimeters follow the approved C 5000 and C 2000 calorimeter models.
- Convenient touch screen operation
- Software provides control chart view and correction calculation
- RFID technology used for decomposition vessel identification
- SD card slot, Ethernet interface for additional data management
- Decomposition vessel with spherical top for faster heat transfer results in shorter experimental times
- Easy bomb preparation due to 'turned around' crucible holder technology
The C 6000 global standards offers a fast dynamic method, the classical adiabatic as well as isoperibol measurement modes. The C 6000 isoperibol offers the same advantages and features, with the exception of the adiabatic measurement mode. Each apparatus can be operated through a user panel and with the software Calwin C 6040. This software opens up further features in data handling with Microsoft SQL, LIMS and correction calculations that follow many calorimeter standard.
- Catalog No:
- 662-2324
- 662-2325
- 662-2326
- 662-2327
- 662-2321
- 662-2322
- 662-2323
- 662-2328
- Permitted ambient temperature:
- 20...30 °C
- 20...30 °C
- 20...30 °C
- 20...30 °C
- 20...30 °C
- 20...30 °C
- 20...30 °C
- 20...30 °C
- Permitted ambient relative humidity:
- 80 %
- 80 %
- 80 %
- 80 %
- 80 %
- 80 %
- 80 %
- 80 %
- Max. measurement range:
- 40000 J
- 40000 J
- 40000 J
- 40000 J
- 40000 J
- 40000 J
- 40000 J
- 40000 J
- Reproducibility (upon analysis with 1 g benzoic acid):
- 0,05% RSD (adiabatic), 0,05% RSD (isoperibol), 0,15% RSD (dynamic)
- 0,05% RSD (adiabatic), 0,05% RSD (isoperibol), 0,15% RSD (dynamic)
- 0,05% RSD (adiabatic), 0,05% RSD (isoperibol), 0,15% RSD (dynamic)
- 0,05% RSD (adiabatic), 0,05% RSD (isoperibol), 0,15% RSD (dynamic)
- 0,05% RSD (adiabatic), 0,05% RSD (isoperibol), 0,15% RSD (dynamic)
- 0,05% RSD (adiabatic), 0,05% RSD (isoperibol), 0,15% RSD (dynamic)
- 0,05% RSD (adiabatic), 0,05% RSD (isoperibol), 0,15% RSD (dynamic)
- 0,05% RSD (adiabatic), 0,05% RSD (isoperibol), 0,15% RSD (dynamic)
- Measuring modes:
- Adiabatic, 22 / 25 / 30 °C (Global standards packages only); isoperibolic, 22 / 25 / 30 °C; dynamic, 22 / 25 / 30 °C
- Adiabatic, 22 / 25 / 30 °C (Global standards packages only); isoperibolic, 22 / 25 / 30 °C; dynamic, 22 / 25 / 30 °C
- Adiabatic, 22 / 25 / 30 °C (Global standards packages only); isoperibolic, 22 / 25 / 30 °C; dynamic, 22 / 25 / 30 °C
- Adiabatic, 22 / 25 / 30 °C (Global standards packages only); isoperibolic, 22 / 25 / 30 °C; dynamic, 22 / 25 / 30 °C
- Adiabatic, 22 / 25 / 30 °C (Global standards packages only); isoperibolic, 22 / 25 / 30 °C; dynamic, 22 / 25 / 30 °C
- Adiabatic, 22 / 25 / 30 °C (Global standards packages only); isoperibolic, 22 / 25 / 30 °C; dynamic, 22 / 25 / 30 °C
- Adiabatic, 22 / 25 / 30 °C (Global standards packages only); isoperibolic, 22 / 25 / 30 °C; dynamic, 22 / 25 / 30 °C
- Adiabatic, 22 / 25 / 30 °C (Global standards packages only); isoperibolic, 22 / 25 / 30 °C; dynamic, 22 / 25 / 30 °C
- Oxygen working pressure:
- 40 bar
- 40 bar
- 40 bar
- 40 bar
- 40 bar
- 40 bar
- 40 bar
- 40 bar
- Flow rate:
- 60 - 70 l/h
- 60 - 70 l/h
- 60 - 70 l/h
- 60 - 70 l/h
- 60 - 70 l/h
- 60 - 70 l/h
- 60 - 70 l/h
- 60 - 70 l/h
- Temperature of the liquid coolant min./max. °C:
- 12 / 27 (cooling with RC 2 basic chiller)
- 12 / 27 (cooling with RC 2 basic chiller)
- 12 / 27 (cooling with RC 2 basic chiller)
- 12 / 27 (cooling with RC 2 basic chiller)
- 12 / 27 (cooling with RC 2 basic chiller)
- 12 / 27 (cooling with RC 2 basic chiller)
- 12 / 27 (cooling with RC 2 basic chiller)
- 12 / 27 (cooling with RC 2 basic chiller)
- Permitted working pressure of the liquid coolant:
- 1,5 bar (cooling with RC 2 basic chiller)
- 1,5 bar (cooling with RC 2 basic chiller)
- 1,5 bar (cooling with RC 2 basic chiller)
- 1,5 bar (cooling with RC 2 basic chiller)
- 1,5 bar (cooling with RC 2 basic chiller)
- 1,5 bar (cooling with RC 2 basic chiller)
- 1,5 bar (cooling with RC 2 basic chiller)
- 1,5 bar (cooling with RC 2 basic chiller)
Frequently Bought Together