You searched for: Standards
Meeting regulations in any industry, standards are essential for periodically checking the accuracy of equipment pieces. By comparing against the known values, output readings detect errors present and inform personnel adjustments are required. Once the settings of the manual or automatic instruments have returned to zero, the reestablished conditions will yield optimal working performance. Calibrating with concentrated standards eliminates the possibility that environmental changes will induce instrumental miscalculation when accuracy matters most.
Refractive Indexx Liquid, Series AA
Supplier: CARGILLE
Refractive index liquids have a broad range of applications in diversified fields.
Expand 1 Items
FAME #13 mix
Supplier: Restek
This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.
Expand 1 Items
FAME #14 mix
Supplier: Restek
This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.
Expand 1 Items
FAME #8 mix
Supplier: Restek
This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.
Expand 1 Items
FAME #5 mix
Supplier: Restek
This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.
Expand 1 Items
FAME #1 mix
Supplier: Restek
This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.
Expand 1 Items
Unleaded gasoline composite standards for UST monitoring
Supplier: Restek
Unleaded gasoline composite standards are comprised of three separate sources each of 87, 89, and 93 octanes blended in equal portions.
Expand 7 Items
Certified reference material, soya-maize oil blend, BCR®
Supplier: LGC Standards PROMOCHEM
A unit contains approximately 5,5 gm soya-maize oil blend in 10 ml amber ampoule.
Expand 1 Items
Elemental analysis standards, portland cement (Ivory)
Supplier: LGC Standards PROMOCHEM
These are intended primarily for the evaluation and calibration of methods for analysis of cements and materials of similar matrix.
Expand 1 Items
House dust, standard reference material, NIST-2585
Supplier: LGC Standards PROMOCHEM
This reference standard is intended for use in evaluating analytical methods for the determination of selected of selected polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyl (PCB) congers, chlorinated pesticides and polybrominated diphenyl ether (PBDE) cogeners in house dust and similar matrices.
Expand 1 Items
SV calibration mix #4 (13 components)
Supplier: Restek
SV Calibration mix #4 contains carbazole (86-74-8); dibenzofuran (132-64-9); diethyl phthalate (84-66-2); 2,4-dinitrotoluene (121-14-2); 2,6-dinitrotoluene (606-20-2); hexachlorobenzene (118-74-1); hexachlorobutadiene (87-68-3); hexachlorocyclopentadiene (77-47-4); hexachloroethane (67-72-1); isophorone (78-59-1); 2-methylnaphthalene (91-57-6); nitrobenzene (98-95-3); 1,2,4-trichlorobenzene (120-82-1).
Expand 1 Items
FAME #2 mix
Supplier: Restek
This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.
Expand 1 Items
8330 calibration mix #1 (7 components)
Supplier: Restek
EPA method 8330 is used to measure explosives residues in water and soil samples, using HPLC with UV detection. Target analytes are nitroaromatic and nitramine explosives and their degradation products. Obtaining pure, neat compounds for Method 8330 reference standards can be very difficult. To ensure the highest quality standards, Restek's Quality Control (QC) lab confirms the identity and purity of mixture components and solvents using one or more of the following techniques: GC-FID, HPLC, GC-ECD, GC-MS, LC-MS, refractive index, and melting point.
Expand 1 Items
8330 calibration mix #2 (7 components)
Supplier: Restek
EPA method 8330 is used to measure explosives residues in water and soil samples, using HPLC with UV detection. Target analytes are nitroaromatic and nitramine explosives and their degradation products. Obtaining pure, neat compounds for Method 8330 reference standards can be very difficult. To ensure the highest quality standards, Restek's Quality Control (QC) lab confirms the identity and purity of mixture components and solvents using one or more of the following techniques: GC-FID, HPLC, GC-ECD, GC-MS, LC-MS, refractive index, and melting point.
Expand 1 Items
Calibration check mix, 8270 acid (6 components)
Supplier: Restek
Calibration check mix, 8270 acid, 2000 µg/ml each in methylene chloride, : N/A, 1 ml/ampoule
Expand 1 Items
Certified reference materials for environmental analysis, IRMM BCR®
Supplier: LGC Standards PROMOCHEM
White clover (trace elements), : N/A
Expand 3 Items
Total Acid Number (TAN) Standards
Supplier: CUSTOM MADE CHEMICALS LAB
Total acid number TAN 17034, 2 mg KOH/g
Expand 4 Items
Residual solvents - Class 1 (5 components)
Supplier: Restek
The solvents consists of five components, they are benzene (10 mg/ml), carbon tetrachloride (20 mg/ml), 1,2-dichloroethane 25 mg/ml, 1,1-dichloroethene (40 mg/ml), and 1,1,1-trichloroethane (50 mg/ml).
Expand 1 Items
Calcinated petroleum coke - trace elements
Supplier: LGC Standards PROMOCHEM
This reference standard is intended primarily for use in the calibration of apparatus and the evaluation of techniques employed in the analysis of calcined petroleum coke and other materials with a similar matrix.
Expand 1 Items
EPA method 8310 PAH mixture
Supplier: Restek
EPA method 8310 PAH mixturecontain 18 components.
Expand 1 Items
Diesel #2/mineral oil (2 components)
Supplier: Restek
The mix consists of diesel fuel #2 composite, mineral oil.
Expand 1 Items
Kerosene (ASTM Class 4 accelerant)
Supplier: Restek
These solutions are prepared from a single-source (one-refinery) product.
Expand 4 Items
E1387 column resolution check mix (13 components)
Supplier: Restek
This mix also can be used for underground storage tank monitoring.
Expand 1 Items
Carbohydrate LC performance check mix (5 components)
Supplier: Restek
This carbohydrate LC performance check mix consist of five components which performance qualification (PQ) determines the precision of the LC system.
Expand 1 Items
Individual VOA surrogate and internal standards for EPA methods
Supplier: Restek
Pentafluoro benzene in purge-and-trap grade methanol, 2000 µg/ml, : N/A
Expand 7 Items
FAPAS series 9 OP pesticide mix 1 (10 components)
Supplier: Restek
Laboratories testing food quality and safety are encouraged to routinely perform proficiency tests. Proficiency testing is an external check of quality. It provides an independent and unbiased assessment of the performance of all aspects of the laboratory, both human and hardware.
Expand 1 Items
607 Nitrosamines calibration mix (3 components)
Supplier: Restek
607 Nitrosamines calibration mix contains N-nitrosodimethylamine, N-nitroso-di-n-propylamine, N-nitrosodiphenylamine.
Expand 1 Items
FAPAS series 5 OC pesticide mix 2 (19 components)
Supplier: Restek
Laboratories testing food quality and safety are encouraged to routinely perform proficiency tests. Proficiency testing is an external check of quality. It provides an independent and unbiased assessment of the performance of all aspects of the laboratory, both human and hardware.
Expand 1 Items
DRO mix (Tennessee/Mississippi) (16 components)
Supplier: Restek
DRO mix (Tennessee/Mississippi), 1000 μg/ml each in methylene chloride, Pk Info: 1 ml/ampoule
Expand 1 Items
Antifoam agent for purge-and-trap samples
Supplier: Restek
Foam generated as purge gas passes through a sample can enter the analytical trap and possibly the GC column. This silica-containing antifoam agent is effective over a wide pH range and will not conflict with chromatography of target analytes.