"Cytiva"
Columns, PD SpinTrap™ G-25
Supplier: Cytiva
PD SpinTrap G-25 is a single-use column for cleanup of large biomolecules.
Expand 1 Items
Amersham™ Protran® Western Blotting Membranes, Nitrocellulose
Supplier: Cytiva
Amersham™ Protran® membranes are manufactured from 100% pure nitrocellulose to ensure the highest binding capacity possible. They are compatible with a variety of detection methods, including isotopic, chemiluminescent, colorimetric and fluorescent. No methanol pre-wetting step is required, making this the membrane of choice for proteins which prefer aqueous environments. Prior to transfer the membrane is simply wetted with water, and then placed in the transfer buffer. No other pretreatment steps are necessary.
Expand 26 Items
Dye terminator removal, illustra™ AutoSeq™ G-50 columns
Supplier: Cytiva
illustra™ AutoSeq™ G-50 columns are specifically designed to remove fluorescent dye-terminators from sequencing reactions prior to analysis on automated sequencers. Effective purification is essential for high quality sequencing results since residual dye-terminators can obscure data. illustra™ AutoSeq™ G-50 consists of MicroSpin™ columns containing Sephadex™ G-50, pre-equilibrated in double-distilled water. This is important because even the small amount of salt in traditional buffers (such as TE buffer) can cause electrophoretic artifacts on salt-sensitive automated sequencers.
Expand 3 Items
Affinity coupling media, NHS-Activated Sepharose™ 4 Fast Flow
Supplier: Cytiva
NHS-activated Sepharose™ 4 Fast Flow is composed of cross-linked 4% agarose beads, NHS activated for coupling amino-containing proteins and peptides in process-scale applications. NHS (N-hydroxysuccinimide) coupling forms a chemically stable amide bond with ligands containing primary amino groups. The resin provides a spacer arm to the coupled ligand and suitable for immobilising smaller protein and peptide ligands.
Expand 1 Items
Affinity chromatography columns, HiTrap™ Protein A HP
Supplier: Cytiva
HiTrap™ Protein A HP is a pre-packed, ready to use Protein A Sepharose™ High Performance column for preparative purification of monoclonal and polyclonal antibodies from ascites, serum and cell culture supernatants.
Expand 5 Items
Sepharose™ CL-2B Gel Filtration Base Matrix
Supplier: Cytiva
Sepharose CL-2B is a well-proven cross-linked agarose gel filtration base matrix and is frequently used for coupling affinity ligands to the matrix. The matrix is not pre-activated and the user performs all steps in coupling.
Expand 1 Items
Protein G Sepharose™ 4 Fast Flow Affinity Chromatography Media
Supplier: Cytiva
Protein G Sepharose 4 Fast Flow has recombinant protein G immobilized by the cyanogen bromide (CNBr) method to Sepharose 4 Fast Flow.
Expand 3 Items
Columns, PD MiniTrap™ G-25
Supplier: Cytiva
PD MiniTrap G-25 columns are prepacked, single-use gravity columns for desalting, buffer exchange, and sample cleanup.
Expand 1 Items
HiLoad Superdex columns, 75 PG
Supplier: Cytiva
Superdex prep grade (pg) is produced by covalent bonding of dextran to highly cross-linked agarose.The separation properties of these media are determined by the dextran component
Expand 2 Items
Affinity coupling media, CNBr-Activated Sepharose™ 4B
Supplier: Cytiva
CNBr-activated Sepharose™ 4B is pre-activated media used for coupling antibodies or other large proteins containing -NH₂ groups to the Sepharose™ media, by the cyanogen bromide method, without an intermediate spacer arm.
Expand 1 Items
Blotting membranes, Amersham™ Hybond™-N+
Supplier: Cytiva
Amersham™ Hybond™-N+ is a positively charged nylon membrane with a binding capacity for nucleic acids up to 600 µg/cm² recommended for use with radioactive or non radioactive chemiluminescence and chemifluorescence detection systems.
Expand 8 Items
Percoll™ PLUS
Supplier: Cytiva
Percoll® PLUS is for preparation of cells, subcellular particles and larger viruses.
Expand 2 Items
Western blotting blocking reagent, Amersham ECL™ Prime
Supplier: Cytiva
Amersham ECL Prime Blocking Reagent is blocking Amersham Protran NC and Amersham Hybond PVDF membranes used with Amersham ECL start, Amersham ECL, Amersham, ECL Prime, Amersham ECL Select and Amersham ECL Plex.
Expand 1 Items
illustra™ MicroSpin™ S-400 HR columns
Supplier: Cytiva
illustra™ MicroSpin™ S-400 HR columns designed for rapid purification of PCR products (>200 bp) from unincorporated primers (<32-mers) and nucleotides using spin-column chromatography.
Expand 1 Items
illustra™ GFX™ PCR DNA and gel band purification kit
Supplier: Cytiva
The illustra GFX PCR DNA and Gel Band Purification kits are for the isolation and concentration of DNA fragments from PCR mixtures, DNA-containing agarose gel bands, enzyme-based DNA modifications, and restriction enzyme digests.
Expand 2 Items
Ficoll® PM400
Supplier: Cytiva
Ficoll® PM400 is a synthetic neutral, highly branched hydrophilic polymer of sucrose with an average molecular weight of 400000. It is used to form density gradients for separating and isolating eukaryotic cells, organelles and bacterial cells, as a stabilising agent and as a preparation medium for isolating mononuclear cells. It is useful for separating cells that are sensitive to centrifugation. Ficoll™ PM400 can also be used in other applications, such in defined culture media, nucleic acid hybridisation, electrophoresis, and immunological studies.
Expand 3 Items
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.



