Order Entry
Austria
ContactUsLinkComponent
100 results for Chromatography Standards

You searched for: Chromatography Standards

Frequently used for calibration, the chromatography standards have a known concentration to test separating equipment for performance faults. Analytical equipment error would impact the dependability of retention time, purity, molecular weight, and compound identification conclusions. Improving data quality, the substances allow personnel to plot analyte signal ratios and obtain concentrations from a calibration curve. Chromatography standards verify instruments are suitable for intended ion exchange, gel filtration, and hydrophobic interaction procedures.

Sort By

Polystyrene standards, GPC/SEC columns calibration

Supplier: VARIAN

Polystyrene standards for many organic solvents either for conventional GPC column calibration or for calibrating light scattering and viscosity detectors that provide equidistant calibration points for greater accuracy.

Expand 67 Items
Loading...

Polymethylmethacrylate standards, GPC/SEC columns calibration

Supplier: VARIAN

Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone and ethyl acetate.

Expand 43 Items
Loading...
XERT-500 column test mix (8 components)

XERT-500 column test mix (8 components)

Supplier: Restek

This contains (C9:0 FAME) methyl nonanoate, (C13) n-tridecane, (C15) n-pentadecane, acenaphthylene, 4-chlorophenol, n-decylamine, 1,6-hexanediol and 1-undecanol (112-42-5).

Expand 1 Items
Loading...
Chiral column test mix (9 components)

Chiral column test mix (9 components)

Supplier: Restek

The mix consists of (C10:0) Methyl decanoate (210 μg/ml), (C11:0) methyl undecanoate (210 μg/ml), (C12) n-dodecane 150 μg/ml, (C12:0) methyl dodecanoate (210 μg/ml), 2,3-butanediol (+/-) (500 μg/ml), 1-heptanol (180 μg/ml), 3-methylphenol (m-cresol) (160 μg/ml), 1-phenylethanol (+/-) (500 μg/ml) and α-pinene (+/-) (500 μg/ml).

Expand 1 Items
Loading...
Test mix for NPI-350 column (8 components)

Test mix for NPI-350 column (8 components)

Supplier: Restek

This test mix for NPI-350 column contains: (C9:0 FAME) Methyl nonanoate (1731-84-6); (C13) n-Tridecane (629-50-5); (C15) n-Pentadecane (629-62-9); Acenaphthylene (208-96-8); 4-Chlorophenol (106-48-9); 1,6-Hexanediol (629-11-8); 4-Propylaniline (2696-84-6); 1-Undecanol (112-42-5).

Expand 1 Items
Loading...
Amine column test mix (GC) (8 components)

Amine column test mix (GC) (8 components)

Supplier: Restek

The amine column test mix consists of (C10) decane (0,60 mg/ml), (C12) dodecane (0.60 mg/ml, 1,2-butanediol (0.60 mg/ml), diethanolamine (DEA) (1.20 mg/ml), diethylenetriamine (1.20 mg/ml), 2,6-dimethylaniline (0.60 mg/ml), 2-nonanol (0.60 mg/ml), pyridine(0.60 mg/ml).

Expand 1 Items
Loading...

Positive electrophoretic mobility standard, NIST-1980

Supplier: LGC Standards PROMOCHEM

This Standard Reference Material (SRM) is intended for use in the evaluation of equipment, and the validation of methodology used to measure electrophoretic mobility.

Expand 1 Items
Loading...

Polystyrene film - IR transmission wavelength standards, NIST-1921B

Supplier: LGC Standards PROMOCHEM

NIST-1921B, Polystyrene film - IR transmission wavelength

Expand 1 Items
Loading...

PIC (paired ion chromatography) reagents for separation by reverse phase chromatography

Supplier: WATERS

Standards for Ion Pair Chromatography, Paired-ionic chromatography reagent B7, heptane sulfonic acid

Expand 1 Items
Loading...

Peptide standard mixture, MassPREP™

Supplier: WATERS

The MassPREP™ peptide standard mixture is useful for the evaluation of HPLC columns and systems dedicated for peptide separations.

Expand 1 Items
Loading...
Sort By
Recommended for You