You searched for: Chromatography Standards
Frequently used for calibration, the chromatography standards have a known concentration to test separating equipment for performance faults. Analytical equipment error would impact the dependability of retention time, purity, molecular weight, and compound identification conclusions. Improving data quality, the substances allow personnel to plot analyte signal ratios and obtain concentrations from a calibration curve. Chromatography standards verify instruments are suitable for intended ion exchange, gel filtration, and hydrophobic interaction procedures.
Polystyrene standards, GPC/SEC columns calibration
Supplier: VARIAN
Polystyrene standards for many organic solvents either for conventional GPC column calibration or for calibrating light scattering and viscosity detectors that provide equidistant calibration points for greater accuracy.
Expand 67 Items
Polymethylmethacrylate standards, GPC/SEC columns calibration
Supplier: VARIAN
Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone and ethyl acetate.
Expand 43 Items
XERT-500 column test mix (8 components)
Supplier: Restek
This contains (C9:0 FAME) methyl nonanoate, (C13) n-tridecane, (C15) n-pentadecane, acenaphthylene, 4-chlorophenol, n-decylamine, 1,6-hexanediol and 1-undecanol (112-42-5).
Expand 1 Items
Chiral column test mix (9 components)
Supplier: Restek
The mix consists of (C10:0) Methyl decanoate (210 μg/ml), (C11:0) methyl undecanoate (210 μg/ml), (C12) n-dodecane 150 μg/ml, (C12:0) methyl dodecanoate (210 μg/ml), 2,3-butanediol (+/-) (500 μg/ml), 1-heptanol (180 μg/ml), 3-methylphenol (m-cresol) (160 μg/ml), 1-phenylethanol (+/-) (500 μg/ml) and α-pinene (+/-) (500 μg/ml).
Expand 1 Items
Test mix for NPI-350 column (8 components)
Supplier: Restek
This test mix for NPI-350 column contains: (C9:0 FAME) Methyl nonanoate (1731-84-6); (C13) n-Tridecane (629-50-5); (C15) n-Pentadecane (629-62-9); Acenaphthylene (208-96-8); 4-Chlorophenol (106-48-9); 1,6-Hexanediol (629-11-8); 4-Propylaniline (2696-84-6); 1-Undecanol (112-42-5).
Expand 1 Items
Amine column test mix (GC) (8 components)
Supplier: Restek
The amine column test mix consists of (C10) decane (0,60 mg/ml), (C12) dodecane (0.60 mg/ml, 1,2-butanediol (0.60 mg/ml), diethanolamine (DEA) (1.20 mg/ml), diethylenetriamine (1.20 mg/ml), 2,6-dimethylaniline (0.60 mg/ml), 2-nonanol (0.60 mg/ml), pyridine(0.60 mg/ml).
Expand 1 Items
Positive electrophoretic mobility standard, NIST-1980
Supplier: LGC Standards PROMOCHEM
This Standard Reference Material (SRM) is intended for use in the evaluation of equipment, and the validation of methodology used to measure electrophoretic mobility.
Expand 1 Items
Polystyrene film - IR transmission wavelength standards, NIST-1921B
Supplier: LGC Standards PROMOCHEM
NIST-1921B, Polystyrene film - IR transmission wavelength
Expand 1 Items
PIC (paired ion chromatography) reagents for separation by reverse phase chromatography
Supplier: WATERS
Standards for Ion Pair Chromatography, Paired-ionic chromatography reagent B7, heptane sulfonic acid
Expand 1 Items
Peptide standard mixture, MassPREP™
Supplier: WATERS
The MassPREP™ peptide standard mixture is useful for the evaluation of HPLC columns and systems dedicated for peptide separations.