You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Analytical guard column, Upchurch Scientific®
Supplier: UPCHURCH SCIENTIFIC
This narrow-bore short column (2,0×20 mm) creates only a slight pressure increase with virtually no detectable theoretical plate loss when used with a 3 mm int.Ø or larger column.
Expand 1 Items
OPTI-LYNX™ Micro Trap Cartridges
Supplier: OPTIMIZE TECHNOLOGIES
Combining a versatile selection of packed beds and the use of a convenient quick-connect holder, OPTI-LYNX™ provides numerous options for chromatographers for on-line or off-line sample clean-up and pre-concentration.
Expand 1 Items
Gel permeation chromatography columns, Styragel® HR
Supplier: WATERS
Styragel® HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterising samples in the low to mid molecular range where high resolution is critical.
Expand 6 Items
Analytical HPLC columns, Nova-Pak® C18
Supplier: WATERS
Nova-Pak® C18 columns are general purpose, silica based, reversed phase C18 columns that are based on 4 µm particle technology.
Expand 4 Items
Reversed phase HPLC columns, Atlantis® Silica HILIC
Supplier: WATERS
Atlantis HILIC silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography.
Expand 2 Items
Analytical HPLC columns, Symmetry® C18
Supplier: WATERS
Symmetry® C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactivated silica.
Expand 13 Items
Reversed phase HPLC columns, µBondapak® C18
Supplier: WATERS
µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.
Expand 5 Items
Analytical HPLC columns, Symmetry® C8
Supplier: WATERS
Symmetry® C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactivated silica.
Expand 5 Items
Preparative columns, µBondapak® C18
Supplier: WATERS
µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.
Expand 1 Items
Analytical HPLC columns, µBondapak® Phenyl
Supplier: WATERS
Column type: HPLC column, µBondapak®, Phenyl, Ø int.: 3,90 mm, Length: 300 mm, Pore size: 125 Å, Particle size: 10 µm
Expand 1 Items
Analytical HPLC columns, XTerra® MS C18
Supplier: WATERS
XTerra® MS C18 columns are general purpose, hybrid-based, reversed phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.
Expand 9 Items
Analytical HPLC columns, XTerra® MS C8
Supplier: WATERS
XTerra® MS C8 columns are general purpose, hybrid-based, reversed phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.
Expand 2 Items
Analytical HPLC columns, XBridge™ BEH C8
Supplier: WATERS
The XBridge™ BEH C8 sorbent is less retentive compared to the XBridge™ BEH C18 sorbent. The trifunctionally bonded sorbent offers the widest usable pH range (1 to 12), superior low pH stability and ultra-low column bleed.
Expand 2 Items
Solid phase extraction cartridges, Sep-Pak® Classic
Supplier: WATERS
Silica-based bonded phase with strong hydrophobicity used to adsorb analytes of even weak hydrophobicity from aqueous solutions.
Expand 1 Items
UPLC columns, ACQUITY UPLC™ BEH phenyl
Supplier: WATERS
These columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds.
Expand 4 Items
Analytical HPLC columns, XTerra® RP18
Supplier: WATERS
XTerra® RP18 columns are general purpose, hybrid-based, reversed phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Expand 6 Items
UPLC columns, ACQUITY UPLC™ BEH Shield RP 18
Supplier: WATERS
These columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Expand 2 Items
Analytical HPLC columns, XTerra® RP8
Supplier: WATERS
XTerra® RP8 columns are general purpose, hybrid-based, reversed phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Expand 1 Items
Reversed phase HPLC columns, Atlantis® T3
Supplier: WATERS
Atlantis T3 columns are universal, silica based, reversed phase C18 columns that provide balanced retention of polar and hydrophobic molecules and useful for developing separations of polar and non-polar compounds.
Expand 7 Items
Analytical HPLC columns, XSelect™ CSH C18
Supplier: WATERS
XSelect™ CSH C18 is a general purpose column that provides alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps to overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed and slow mobile-phase re-equilibration.
Expand 2 Items
Columns, ACQUITY UPLC™ CSH C18
Supplier: WATERS
ACQUITY UPLC method validation kit includes three batches of chromatographic media (derived from different base particles) to judge the quality, reliability, and consistency of the chromatographic method.
Expand 3 Items
Solid phase extraction cartridge, Sep-Pak® XPoSure™ Plus
Supplier: WATERS
Specially designed for monitoring aldehydes in indoor air.
Expand 1 Items
Reversed phase HPLC columns, Atlantis® dC18
Supplier: WATERS
Atlantis® dC18 columns are universal, silica-based, reversed phase C18 columns that are used for polar compound retention. The Atlantis® dC18 columns feature di-functionally bonded C18 ligands that have been optimised for use with highly aqueous mobile phases, including 100% water.
Expand 7 Items
UPLC columns, ACQUITY UPLC™ CSH phenyl-hexyl
Supplier: WATERS
These columns provides complementary selectivity to straight-chain-alkyl phases, particularly for polyaromatic compounds. Built on Charged Surface Hybrid (CSH) particle platform.
Expand 1 Items
UPLC columns, ACQUITY UPLC™ BEH C8
Supplier: WATERS
The particals and chemistries of the ACQUITY UPLC columns are used to separate and with maximum speed, sensitivity and resolution without compromise, it produce the ideal combination of ultra performance efficiencies wide complementary selectivities.
Expand 2 Items
Solid phase extraction cartridges, Sep-Pak® Vac
Supplier: WATERS
These cartridges deliver the option of minimum sample preparation. Consists of moulded, high purity PP syringe-barrel bodies with two PE frits to contain the packing material.
Expand 6 Items
Analytical HPLC columns, XBridge™ BEH C18
Supplier: WATERS
XBridge™ BEH C18 sorbent can be used over an entire range of mobile phase pH (1 to 12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Expand 5 Items
Analytical HPLC columns, SunFire™ C18
Supplier: WATERS
SunFire™ columns provide symmetrical peak shapes for improved resolution. With new bonding and endcapping technologies, they offer great efficiency for acid, neutral, and basic compounds at low and intermediate pH ranges. They are compatible with mass spectrometry applications, providing sharp peaks, high sensitivity, large peak capacities and very low bleed.
Expand 10 Items
Analytical HPLC columns, SunFire™ C8
Supplier: WATERS
SunFire™ columns provide symmetrical peak shapes for improved resolution. With new bonding and endcapping technologies, they offer great efficiency for acid, neutral, and basic compounds at low and intermediate pH ranges. They are compatible with mass spectrometry applications, providing sharp peaks, high sensitivity, large peak capacities and very low bleed.
Expand 1 Items
Guard cartridges, Waters Spherisorb®
Supplier: WATERS
The cartridges are compatible with the Spherisorb® cartridge system. They may also be used in a stand-alone holder or in integral extended cartridge end-fitting.