Order Entry
Austria
ContactUsLinkComponent
231 results for "Solid Phase Extraction"

 

Sort By

Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying

Supplier: VARIAN

Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.

Expand 5 Items
 
Empty solid phase extraction cartridges with two frits, Bond Elut™

Empty solid phase extraction cartridges with two frits, Bond Elut™

Supplier: VARIAN

Clean PP reservoirs contain two PP frits pre-inserted, an ideal configuration for simple filtration.

Expand 7 Items
 

Solid phase extraction cartridges, Bond Elut™ NEXUS and NEXUS WCX

Supplier: VARIAN

Bond Elut™ NEXUS is an ultra-clean polymeric sorbent which has bi-modal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no pre-conditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine.

Based on the same base polymer technology, Bond Elut™ NEXUS WCX is a weak cation exchange sorbent that offers extra selectivity for analytes, such as quaternary ammonium drugs and anabolic steroids.

Expand 8 Items
 
SPE columns, CHROMABOND® CN

SPE columns, CHROMABOND® CN

Supplier: MACHEREY-NAGEL

CHROMABOND® CN is a cyanopropyl modified silica phase for solid phase extraction.

Expand 2 Items
 

Aluminiumoxid aktiviert neutral Brockmann Grade I, Supelco®

Supplier: Merck

Brockmann aluminum oxides are suitable for column chromatography and adsorptive filtration. Aluminum oxides are generally used as solid support phases in solid phase extraction (SPE)-based clean-up procedures employed in chromatographic methods

Expand 2 Items
 
Positive pressure manifold, ASPEC®

Positive pressure manifold, ASPEC®

Supplier: GILSON LCMS

The ASPEC® Positive pressure manifold uses positive pressure to improve reproducibility and recovery for solid phase extraction (SPE) applications.

Expand 1 Items
 

Pesticide reference standard, Promecarb, PESTANAL®, analytical standard, Supelco®

Supplier: Merck

Promecarb may be used as a reference standard for the determination of promecarb in water by solid-phase extraction and liquid chromatography coupled with ionspray mass spectrometry.

Expand 1 Items
 

Flash cartridges, Mega Bond Elut™

Supplier: VARIAN

Flash cartridges for the purification of organic compounds, and also for scale-up, solid phase extraction.

Expand 24 Items
 

Cerex® FLORASIL SPE Columns

Supplier: Tecan

Florisil is used for sample preparation (solid phase extraction) of e.g., organic tin compounds and aliphatic carboxylic acids. Florisil is a magnesium silicate.

Expand 1 Items
 
ASPEC® 241 system

ASPEC® 241 system

Supplier: GILSON LCMS

This compact ASPEC® system combines positive pressure solid phase extraction (SPE) with small footprint and precise liquid handling for reliable automated SPE applications.

Expand 1 Items
 

Organic reference standard, 4-Hydroxy-4-methyl-2-pentanone, analytical standard, Supelco®

Supplier: Merck

4-Hydroxy-4-methyl-2-pentanone may be used as an internal standard in the analysis of volatile odor-active compounds present in wine using solid phase extraction with gas chromatography (SPE-GC).

Expand 1 Items
 

Organic reference standard, Bisphenol E, analytical standard, Supelco®

Supplier: Merck

Bisphenol E may be used as a reference standard in the determination of bisphenol E in beverages using on-line solid-phase extraction with fast liquid chromatography coupled with tandem mass spectrometry (on-line SPE fast LC-MS/MS).

Expand 1 Items
 
Sample delivery system, Resprep®

Sample delivery system, Resprep®

Supplier: Restek

This sample delivery system is used to transfer large volumes of low viscosity samples directly from a bottle to a solid phase extraction cartridge or to a disk on a vacuum manifold system for extraction or cleanup.

Expand 1 Items
 
Microplates, 24-well, Whatman™ UNIFILTER®

Microplates, 24-well, Whatman™ UNIFILTER®

Supplier: Whatman products (Cytiva)

The 10 ml UNIFILTER is used with large sample or reagent volumes. Typical applications include biomolecule purification by solid phase extraction and organic synthesis in combinatorial chemistry library generation.

Expand 3 Items
 
ASPEC® 274 system

ASPEC® 274 system

Supplier: GILSON LCMS

This ASPEC® system for positive pressure solid phase extraction (SPE) automation maximises throughput by processing up to four samples in parallel. With its small footprint and multiple probes, it is the ideal choice for reproducible and efficient sample cleanup for clinical, forensic, doping, food, and environmental testing labs.

Expand 1 Items
 

Solid phase microextraction fibers

Supplier: VARIAN

Solid phase microextraction (SPME) is a technique for extracting analytes from solid, liquid or gaseous samples by adsorbing them onto the SPME fiber and then desorbing them into an inlet, either on a gas chromatograph (GC) or an HPLC system. SPME is amenable to automation using an autosampler or it can be performed manually as well.

Expand 30 Items
 
Vacuum manifolds, Visiprep

Vacuum manifolds, Visiprep

Supplier: Merck

Solid phase extraction vacuum manifolds allow to simultaneously process up to 12 or up to 24 SPE tubes. Precise flow control is provided through each SPE tube by rotating the independent, screw-type valves in the cover, this ensures the packing will not dry out in some tubes while others finish draining.

Expand 4 Items
 

SPME fibers and arrows

Supplier: Thermo Fisher Scientific

Solid Phase Micro Extraction (SPME) uses a thin-fused silica fiber coated with a sorbent which enables extraction of compounds of interest from liquid or gaseous samples through absorption or adsorption. The fiber is then moved to the injector and the compounds thermally desorbed. The SPME consumables come in two formats SPME fibers and SPME arrows.

Expand 14 Items
 
LH software, TRILUTION®

LH software, TRILUTION®

Supplier: GILSON LCMS

TRILUTION® LH provides a solution for customers using Windows 10 and is a comprehensive software package for seamless automation of all liquid handling and solid phase extraction (SPE) methods. With its intuitive interface, simple drag-and-drop method creation, and application simulation, it combines flexibility and ease of use.

Expand 1 Items
 
Mikroextraktion durch gepackte Sorbentien (MEPS™)

Mikroextraktion durch gepackte Sorbentien (MEPS™)

Supplier: Trajan Scientific and Medical

Die Mikroextraktion durch gepackte Sorbentien (Micro Extraction by Packed Sorbent, MEPS™) ist eine Neuentwicklung auf dem Gebiet der Probenvorbereitung mit SPE (Solid-Phase Extraction / Fest-phasenextraktion). Das MEPS™-Produkt besteht aus zwei Komponenten, und zwar aus der MEPS™-Spritze und dem MEPS™-Kanüleneinsatz BIN (Barrel Insert and Needle Assembly). Für die Probenvorbereitung mit MEPS™ stehen folgende Sorbentien zur Verfügung: Umkehrphasen, Normalphasen, Mischmodus und Ionenaustauscher. Da die MEPS™-BINs für kleine Probenvolumen (bis unter 10 µl) verwendet werden können, eignen sie sich sehr gut für den Online-Einsatz im Rahmen von LC-MS-Analysen von Proben mit geringem Volumen.

Expand 7 Items
 

SampliQ SPE-Kartuschen

Supplier: Agilent

Hochwertige SampliQ SPE-Produkte (Solid Phase Extraction) helfen dem Benutzer, Proben aus komplexen Matrizen sicher zu extrahieren und zu konzentrieren und sorgen so vom ersten Schritt an für schnelle, genaue und reproduzierbare Ergebnisse. Die SampliQ-Reihe umfasst Polymere, Silikat- und Nicht-Silikat-Optionen, um den spezifischen SPE-Anforderungen des Benutzers gerecht zu werden.

Expand 14 Items
 
Platte mit 96 Wells, runde Well, Bond Elut™

Platte mit 96 Wells, runde Well, Bond Elut™

Supplier: VARIAN

Platten zur Festphasenextraktion (SPE), 96-round well plate, Bond Elut™, Polymere Sorbenzien, Plexa, 10 mg

Expand 44 Items
 
Accessories for 96-well Bond Elut™ plates

Accessories for 96-well Bond Elut™ plates

Supplier: VARIAN

96-well manifold, acrylic

Expand 6 Items
 
Accessories for SPE plates, OMIX 96-well VersaPlate™

Accessories for SPE plates, OMIX 96-well VersaPlate™

Supplier: VARIAN

Grundplatte für VersaPlate™ Röhrchen, 96-Well

Expand 1 Items
 

Supelco® TraceCERT® Organischer Referenzstandard, Metrafenon

Supplier: Merck

Metrafenon-CRM kann auch in der Rückstandsanalyse von folgenden Stoffen verwendet werden: 209 Pestizide und persistente organische Schadstoffe (POPs), die mit einem QuEChERS-basierten Verfahren aus frischen Leberproben von Rindern und Hühnern extrahiert wurden, wobei Gaschromatographie in Verbindung mit Tandem-Massenspektrometrie (GC-MS/MS) zum Einsatz kam. 252 Pestizide aus Oberflächenwasserproben durch Festphasenextraktion (SPE) unter Verwendung von Flüssigchromatographie-Quadrupol-Orbitrap-Tandem-Massenspektrometrie mit hoher Auflösung extrahiert. 250 Pestizidrückstände aus 103 verarbeiteten Obstproben mit der QuEChERS-Methode unter Verwendung von Ultrahochleistungs-Flüssigkeitschromatographie-Tandem-Massenspektrometrie (UHPLC-MS/MS) extrahiert. 379 Pestizide in menschlichen Serumproben mit der QuEChERS-Methode unter Verwendung von Flüssigchromatographie-Tandem-Massenspektrometrie (LC-MS/MS) extrahiert. Metrafenon in neun frischen Gemüseproben unter Verwendung von Matrix-Festphasendispersion (MSPD) und HPLC-UV. Metrafenon in Bittergurken- und Bodenproben unter Verwendung von Gaschromatographie kombiniert mit einem Elektroneneinfangdetektor (GC-ECD).

Expand 1 Items
 
Extraktionseinheit und Trocknungsaufsatz, LiChrolut®

Extraktionseinheit und Trocknungsaufsatz, LiChrolut®

Supplier: Merck

Jeder einzelne Schritt im Zusammenhang mit der Festphasenextraktion kann mit der LiChrolut® Extraktionseinheit durchgeführt werden. Diese transparente und vakuumtaugliche Einheit aus Glas kann verwendet werden, um bis zu 12 Proben gleichzeitig vorzubereiten.

Expand 3 Items
 

Supelco® TraceCERT® Organischer Referenzstandard, Monolinuron

Supplier: Merck

Monolinuron CRM kann auch wie unten angegeben verwendet werden: Bestimmung von 252 Pestiziden, die aus Oberflächenwasserproben durch Festphasenextraktion (SPE) unter Verwendung von Flüssigchromatographie-Quadrupol-Orbitrap-Tandem-Massenspektrometrie mit hoher Auflösung extrahiert wurden. Extraktion von 13 Pestiziden aus vier Grundwasser- und drei Flusswasserproben unter Verwendung des mesoporösen Feststoffs MSU-1 auf Siliciumdioxidbasis als Sorbens für ihre Festphasenextraktion (SPE), gefolgt von einer Bestimmung mittels Ultra-Performance-Flüssigkeitschromatographie-Triple-Quadrupol-Massenspektrometrie (UHPLC-QqQ-MS/MS). Entwicklung und Validierung einer UHPLC-Diodenarray-Detektionsmethode (DAD) zur gleichzeitigen Bestimmung von Harnstoff- und Tebuthiuron-Herbiziden in vier frischen Gemüseproben. Multirückstandsanalyse von 50 Herbiziden in 51 Getreideproben von Soja, Mais und Weizen mittels Ultra-Performance-Flüssigkeitschromatographie-Elektrospray-Ionisations-Massenspektrometrie (UPLC-ESI-MS). Extraktion von 109 Pestizidrückständen verschiedener chemischer Klassen aus 345 Tomatenproben mittels modifizierter QuEChERS-Methode und deren Bestimmung mittels Flüssigkeitschromatographie-Tandem-Massenspektrometrie (LC-MS/MS). Gleichzeitige Analyse von 238 Pestiziden und 78 Tierarzneimitteln in 80 Kuhmilchproben mittels ultraschneller Flüssigkeitschromatographie-Tandem-Massenspektrometrie (UFLC-MS/MS) und Gaschromatographie-Tandem-Massenspektrometrie (GC-MS/MS).

Expand 1 Items
 

Supelco® TraceCERT® Organischer Referenzstandard, Tebutam

Supplier: Merck

Tebutam CRM kann auch wie folgt verwendet werden:
Optimierung der Probenextraktion basierend auf QuEChERS und dispersiver Festphasenextraktion (d-SPE) zur Reinigung mehrerer Rückstände von 120 Pestiziden, 16 polyzyklischen aromatischen Kohlenwasserstoffen und 22 polychlorierten Biphenylen durch Flüssig- und Gaschromatographie gekoppelt mit Tandem-Massenspektrometrie (MS/MS)
Auswertung von 250 Pestizidrückständen, die mit der QuEChERS-Methode aus 103 verarbeiteten Obstproben unter Verwendung von Ultrahochleistungsflüssigkeitschromatographie-Tandem-Massenspektrometrie (UHPLC-MS/MS) extrahiert wurden
Bestimmung von 90 Pestiziden, 16 polyzyklischen aromatischen Kohlenwasserstoffen und 22 polychlorierte Biphenyle in Honigproben durch Verwendung von QuEChERS in Kombination mit dispersiver Festphasenextraktion (SPME) zur Probenvorbehandlung und Flüssigchromatographie-Triple-Quadrupol-Tandem-Massenspektrometrie und Gaschromatographie-Ionenfallen-Tandem-Massenspektrometrie zur Quantifizierung
Screening und Quantifizierung von 569 Pestiziden in Geißblattproben durch eine Kombination aus Ultrahochleistungsflüssigkeitschromatographie (UHPLC) und Quadrupol-Orbitrap-Hochauflösungs-Massenspektrometrie
Gleichzeitige Bestimmung von 134 Pestizidrückständen in Teeproben durch d-SPE-Extraktion mit einem Multifunktionsfilter (MFF), gefolgt von Ultrahochleistungsflüssigchromatographie (UPLC) und Quadrupol-Flugzeit-Massenspektrometrie (TOF-MS).

Expand 1 Items
 

Supelco® TraceCERT® Organischer Referenzstandard, Simazin

Supplier: Merck

Simazin CRM kann auch wie unten angegeben verwendet werden: Entwicklung und Validierung einer ultraschallunterstützten dispersiven Flüssig-Flüssig-Mikroextraktionsmethode (UA-DLLME) zur Probenextraktion, gefolgt von einer gaschromatographisch-massenspektrometrischen Bestimmung endokrin wirksamer Herbizide in den Fluss- und Meerwasserproben. Bestimmung von Triazin-Pestizidrückständen in Proben von Äpfeln, Birnen, Karotten, Kartoffeln, Tomaten, Avocados, Gurken, Spinat, Bananen und Orangen durch modifizierte QuEChERS- und Festphasenextraktionsverfahren (SPE), gefolgt von einer Flüssigchromatographie-Photodiodenarray-Analyse (LC-DAD). Mehrfachrückstandsanalyse von 67 Pestiziden in Olivenöl-, Oliven- und Avocadoproben durch Flüssigchromatographie-Tandem-Massenspektrometrie (LC-MS/MS) zur Bewertung verschiedener Reinigungssorbentien. Quantifizierung von 20 Pestiziden in Aal- und Garnelenproben durch eine geplante Mehrfachreaktionsüberwachungsmethode (sMRM) und QuEChERS mit EDTA zur Probenextraktion und -reinigung. Analyse von 35 Mikroverunreinigungen einschließlich Pestiziden in Wasserproben durch Flüssigchromatographie-Tandem-Massenspektrometrie (LC-MS/MS) nach ihrer Festphasenextraktion. Gleichzeitige Quantifizierung von 58 Arzneimitteln und Körperpflegeprodukten (PPCPs) und Pestiziden in Wasserproben durch lösungsmittelbasierte deemulgierende dispersive Flüssig-Flüssig-Mikroextraktion (SD-DLLME) kombiniert mit Flüssigchromatographie-Tandem-Massenspektrometrie (LCMS/MS).

Expand 1 Items
 
Festphasenextraktions-Kartuschen, LiChrolut®

Festphasenextraktions-Kartuschen, LiChrolut®

Supplier: Merck

LiChrolut® SPE-Kartuschen und Zubehörteile für die Festphasenextraktion werden nach höchsten Qualitätsstandards hergestellt. Alle unten aufgeführten SPE-Kartuschen bestehen aus PP (Polypropylen), wenn nicht anders angegeben. Sie sind mit allen automatisierten SPE-Instrumenten und -Robotern kompatibel. Drei wichtige Kriterien werden sorgfältig kontrolliert:

Expand 8 Items
 
Sort By
Recommended for You