This rugged, waterproof portable meter is designed for a wide range of pH, ion concentration, conductivity, dissolved oxygen and temperature testing and field applications. It can be used in the most demanding locations thanks to its IP67-rated housing. The meter offers three measuring channels allowing users to measure pH, conductivity and DO simultaneously or view each channel separately.
- Up to five point pH calibrations with calibration editing option that allows individual points to be fixed without a full recalibration
- Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings
- Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
- Measurement stability indicator and selectable read modes – Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
- Data log collects and date/time stamps up to 5000 measurement sets with optional sample ID and user ID
- Calibration log stores ten most recent calibrations
- Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two.
Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings. Transfer single, range or all data points to printer or computer.
Auto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate. Use linear, non linear, EP (USP) or off conductivity temperature compensation with 5, 10, 15, 20 or 25 °C reference temperatures. 3-years replacement warranty.
Certifications: TUV 3-1, FCC Class A.
Delivery information: Supplied with four with 4 AA batteries, literature CD, printed quick start guide, computer interface cable and meter test certificate.
The kit additionally includes: 8107UWMMD ROSS Ultra Triode gel filled epoxy-body pH/ATC electrode (3 m cable), 013010MD DuraProbe 4-cell (K=0,475) epoxy-body conductivity sensor (3 m cable), 087010MD RDO optical DO sensor (3 m cable), calibration sleeve and guard, Orion pH 4/7/10 buffer pouches (10 packs each), ROSS electrode storage solution (475 ml), Orion rinse solution pouches (10 packs), Orion 1413 µS conductivity standard pouches (10 packs), Orion Star A series portable meter armor and Orion Star A series hard-sided field case.
2 Optionen unten verfügbar
Product Details & Documents
This rugged, waterproof portable meter is designed for a wide range of pH, ion concentration, conductivity, dissolved oxygen and temperature testing and field applications. It can be used in the most demanding locations thanks to its IP67-rated housing. The meter offers three measuring channels allowing users to measure pH, conductivity and DO simultaneously or view each channel separately.
- Up to five point pH calibrations with calibration editing option that allows individual points to be fixed without a full recalibration
- Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings
- Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
- Measurement stability indicator and selectable read modes – Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
- Data log collects and date/time stamps up to 5000 measurement sets with optional sample ID and user ID
- Calibration log stores ten most recent calibrations
- Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two.
Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings. Transfer single, range or all data points to printer or computer.
Auto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate. Use linear, non linear, EP (USP) or off conductivity temperature compensation with 5, 10, 15, 20 or 25 °C reference temperatures. 3-years replacement warranty.
Certifications: TUV 3-1, FCC Class A.
Delivery information: Supplied with four with 4 AA batteries, literature CD, printed quick start guide, computer interface cable and meter test certificate.
The kit additionally includes: 8107UWMMD ROSS Ultra Triode gel filled epoxy-body pH/ATC electrode (3 m cable), 013010MD DuraProbe 4-cell (K=0,475) epoxy-body conductivity sensor (3 m cable), 087010MD RDO optical DO sensor (3 m cable), calibration sleeve and guard, Orion pH 4/7/10 buffer pouches (10 packs each), ROSS electrode storage solution (475 ml), Orion rinse solution pouches (10 packs), Orion 1413 µS conductivity standard pouches (10 packs), Orion Star A series portable meter armor and Orion Star A series hard-sided field case.
Spezifikationen für diese Produktfamilie
Spezifikationen
- Catalog No:
- 665-0281
- 665-0282
- Modell:
- A329
- A329
- pH - Bereich:
- –2,000...+20,000
- –2,000...+20,000
- pH - Auflösung:
- 0,1 / 0,01 / 0,001
- 0,1 / 0,01 / 0,001
- pH - Genauigkeit:
- ±0,002
- ±0,002
- pH - Kalibrierung:
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- mV - Bereich:
- ±2000,0
- ±2000,0
- mV - Auflösung:
- 0,1
- 0,1
- mV - Genauigkeit:
- ±0,2 mV or 0,05%
- ±0,2 mV or 0,05%
- ISE Bereich:
- 0,0001 - 19900
- 0,0001 - 19900
- ISE Auflösung:
- 0,0001 minimum, 1 to 3 significant digits (user selectable)
- 0,0001 minimum, 1 to 3 significant digits (user selectable)
- ISE Genauigkeit:
- ±0,2 mV or ±0,05% of reading, whichever is greater
- ±0,2 mV or ±0,05% of reading, whichever is greater
- ISE Kalibrierung:
- Up to 5 points
- Up to 5 points
- ISE Einheiten:
- ppm, M, mg/l, %, ppb, none
- ppm, M, mg/l, %, ppb, none
- Leitfähigkeitsbereich:
- 0,001 µS/cm - 3000 mS/cm
- 0,001 µS/cm - 3000 mS/cm
- Auflösung der Leitfähigkeit:
- 0,001 μS minimum, auto ranging, up to 4 significant digits
- 0,001 μS minimum, auto ranging, up to 4 significant digits
- Genauigkeit der Leitfähigkeit:
- ±0,5% of reading ±1 digit
- ±0,5% of reading ±1 digit
- Zellkonstante Leitfähigkeit:
- 0,001 - 199,9 cm⁻¹
- 0,001 - 199,9 cm⁻¹
- Kalibrierung der Leitfähigkeit:
- Up to 5 points
- Up to 5 points
- Referenztemperatur Leitfähigkeit:
- 5/10/15/20/25 °C
- 5/10/15/20/25 °C
- Spezifischer Widerstand - Bereich:
- 2 Ω/cm - 100 MΩ/cm
- 2 Ω/cm - 100 MΩ/cm
- Spezifischer Widerstand - Genauigkeit:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- Resistivity resolution:
- 1 ohm or 0,1 meg-ohm, auto ranging
- 1 ohm or 0,1 meg-ohm, auto ranging
- Salinität - Bereich:
- 0,06 - 80,00 psu / 0,05 - 42,00 ppt
- 0,06 - 80,00 psu / 0,05 - 42,00 ppt
- Salinität - Auflösung:
- 0,01 psu or 0,01 ppt minimum, auto ranging
- 0,01 psu or 0,01 ppt minimum, auto ranging
- Salinität - Genauigkeit:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- TDS - Bereich:
- 0,001 - 200,0 ppm
- 0,001 - 200,0 ppm
- TDS - Auflösung:
- 0,001 ppm minimum, auto ranging, up to 4 significant digits
- 0,001 ppm minimum, auto ranging, up to 4 significant digits
- TDS - Genauigkeit:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- TDS - Umrechnungsfaktor:
- Linear (0,02 - 9,99)
- Linear (0,02 - 9,99)
- DO Konzentration:
- 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
- 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
- Sauerstoff - Auflösung:
- 0,1 / 0,01 mg/L
- 0,1 / 0,01 mg/L
- Sauerstoff - Sättigung:
- 0 - 600 % (polarographic); 0 - 500 % (RDO)
- 0 - 600 % (polarographic); 0 - 500 % (RDO)
- DO Genauigkeit:
- Polarographic: ±0,2 mg/l or ±2% of reading, whichever is greater
RDO: ±0,1 mg/l (up to 8 mg/), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l) - Polarographic: ±0,2 mg/l or ±2% of reading, whichever is greater
RDO: ±0,1 mg/l (up to 8 mg/), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
- DO Kalibrierung:
- Water-saturated air, air saturated water, manual (Winkler) and zero point
- Water-saturated air, air saturated water, manual (Winkler) and zero point
- Sauerstoff – Luftdruckbereich:
- Automatic or manual, 450 - 850 mmHg
- Automatic or manual, 450 - 850 mmHg
- Temperaturbereich:
- –5,0...+105,0 °C (–5,0...+50,0 °C with DO)
- –5,0...+105,0 °C (–5,0...+50,0 °C with DO)
- Temperaturauflösung:
- 0,1 °C
- 0,1 °C
- Temperaturgenauigkeit:
- ±0,1 °C
- ±0,1 °C
- Temperatur-Kalibrierung:
- 1 point temperature offset calibration
- 1 point temperature offset calibration
- Temperatur - Kompensation:
- Automatic or manual
- Automatic or manual
- Druckbereiche:
- 400 - 850 mm Hg
- 400 - 850 mm Hg
- Pressure resolution:
- 1 mm Hg
- 1 mm Hg
- Display:
- Graphic LCD with backlight
- Graphic LCD with backlight
- Akku-Typ:
- 4 AA (included)
- 4 AA (included)
- Batterielebensdauer:
- 800 hours
- 800 hours
- Stromversorgung:
- AC adapter or 4 AA batteries
- AC adapter or 4 AA batteries
- Konformität:
- IP 67
- IP 67
- Datenprotokollierung - Logfunktion:
- Manual / Automatic with AUTO-READ™
- Manual / Automatic with AUTO-READ™
- Kapazität Datenprotokollierung:
- 5000
- 5000
- Speicher:
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Sprachen:
- English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
- English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
- Schutzklasse:
- IP 67
- IP 67
- Anschlüsse:
- BNC, pin tip, 8- and 9-pin mini-DIN
- BNC, pin tip, 8- and 9-pin mini-DIN
- Ausgänge:
- RS232, USB
- RS232, USB
- Eingang:
- 3 measuring channels
- 3 measuring channels
- Alarm:
- High/low limit alarm, calibration due alarm
- High/low limit alarm, calibration due alarm
- Anzahl der Kanäle:
- 3
- 3
- Kalibrierung:
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- Kalibrierpunkte:
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- B×T×H:
- 60×105×240 mm
- 60×105×240 mm
- Gewicht:
- 0,5 kg
- 0,5 kg
Spezifikationen
Product Family Options
Produktinformationen
- BezeichnungVerfügbarkeitPreis
- Handheld pH/ISE/conductivity/DO meter Orion Star A329, instrument aloneEinloggen für Verfügbarkeit1 * 1 ST2 030,00 €Spezifikationen:
Mehr
Specifications
Cat. No.665-0281ModellA329pH - Bereich–2,000...+20,000pH - Auflösung0,1 / 0,01 / 0,001pH - Genauigkeit±0,002pH - KalibrierungUp to 5 points; Automatic buffer recognition (USA/NIST and DIN)mV - Bereich±2000,0mV - Auflösung0,1mV - Genauigkeit±0,2 mV or 0,05%ISE Bereich0,0001 - 19900ISE Auflösung0,0001 minimum, 1 to 3 significant digits (user selectable)ISE Genauigkeit±0,2 mV or ±0,05% of reading, whichever is greaterISE KalibrierungUp to 5 pointsISE Einheitenppm, M, mg/l, %, ppb, noneLeitfähigkeitsbereich0,001 µS/cm - 3000 mS/cmAuflösung der Leitfähigkeit0,001 μS minimum, auto ranging, up to 4 significant digitsGenauigkeit der Leitfähigkeit±0,5% of reading ±1 digitZellkonstante Leitfähigkeit0,001 - 199,9 cm⁻¹Kalibrierung der LeitfähigkeitUp to 5 pointsReferenztemperatur Leitfähigkeit5/10/15/20/25 °CSpezifischer Widerstand - Bereich2 Ω/cm - 100 MΩ/cmSpezifischer Widerstand - Genauigkeit0,5% of reading ±1 digitResistivity resolution1 ohm or 0,1 meg-ohm, auto rangingSalinität - Bereich0,06 - 80,00 psu / 0,05 - 42,00 pptSalinität - Auflösung0,01 psu or 0,01 ppt minimum, auto rangingSalinität - Genauigkeit0,5% of reading ±1 digitTDS - Bereich0,001 - 200,0 ppmTDS - Auflösung0,001 ppm minimum, auto ranging, up to 4 significant digitsTDS - Genauigkeit0,5% of reading ±1 digitTDS - UmrechnungsfaktorLinear (0,02 - 9,99)DO Konzentration0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)Sauerstoff - Auflösung0,1 / 0,01 mg/LSauerstoff - Sättigung0 - 600 % (polarographic); 0 - 500 % (RDO)DO GenauigkeitPolarographic: ±0,2 mg/l or ±2% of reading, whichever is greater
RDO: ±0,1 mg/l (up to 8 mg/), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)DO KalibrierungWater-saturated air, air saturated water, manual (Winkler) and zero pointSauerstoff – LuftdruckbereichAutomatic or manual, 450 - 850 mmHgTemperaturbereich–5,0...+105,0 °C (–5,0...+50,0 °C with DO)Temperaturauflösung0,1 °CTemperaturgenauigkeit±0,1 °CTemperatur-Kalibrierung1 point temperature offset calibrationTemperatur - KompensationAutomatic or manualDruckbereiche400 - 850 mm HgPressure resolution1 mm HgDisplayGraphic LCD with backlightAkku-Typ4 AA (included)Batterielebensdauer800 hoursStromversorgungAC adapter or 4 AA batteriesKonformitätIP 67Datenprotokollierung - LogfunktionManual / Automatic with AUTO-READ™Kapazität Datenprotokollierung5000SpeicherNon-volatile memory preserves data log, calibration log and meter settingsSprachenEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software updateSchutzklasseIP 67AnschlüsseBNC, pin tip, 8- and 9-pin mini-DINAusgängeRS232, USBEingang3 measuring channelsAlarmHigh/low limit alarm, calibration due alarmAnzahl der Kanäle3KalibrierungpH with calibration editing option, ion concentration (ISE) with calibration editing option, relativKalibrierpunkte1 point relative mV (RmV) mode, 1 point ORP modeB×T×H60×105×240 mmGewicht0,5 kg - Handheld pH/ISE/conductivity/DO meter Orion Star A329, kit incl. pH electrode, conductivity cell and RDO optical sensorEinloggen für Verfügbarkeit1 * 1 ST3 060,00 €Spezifikationen:
Mehr
Specifications
Cat. No.665-0282ModellA329pH - Bereich–2,000...+20,000pH - Auflösung0,1 / 0,01 / 0,001pH - Genauigkeit±0,002pH - KalibrierungUp to 5 points; Automatic buffer recognition (USA/NIST and DIN)mV - Bereich±2000,0mV - Auflösung0,1mV - Genauigkeit±0,2 mV or 0,05%ISE Bereich0,0001 - 19900ISE Auflösung0,0001 minimum, 1 to 3 significant digits (user selectable)ISE Genauigkeit±0,2 mV or ±0,05% of reading, whichever is greaterISE KalibrierungUp to 5 pointsISE Einheitenppm, M, mg/l, %, ppb, noneLeitfähigkeitsbereich0,001 µS/cm - 3000 mS/cmAuflösung der Leitfähigkeit0,001 μS minimum, auto ranging, up to 4 significant digitsGenauigkeit der Leitfähigkeit±0,5% of reading ±1 digitZellkonstante Leitfähigkeit0,001 - 199,9 cm⁻¹Kalibrierung der LeitfähigkeitUp to 5 pointsReferenztemperatur Leitfähigkeit5/10/15/20/25 °CSpezifischer Widerstand - Bereich2 Ω/cm - 100 MΩ/cmSpezifischer Widerstand - Genauigkeit0,5% of reading ±1 digitResistivity resolution1 ohm or 0,1 meg-ohm, auto rangingSalinität - Bereich0,06 - 80,00 psu / 0,05 - 42,00 pptSalinität - Auflösung0,01 psu or 0,01 ppt minimum, auto rangingSalinität - Genauigkeit0,5% of reading ±1 digitTDS - Bereich0,001 - 200,0 ppmTDS - Auflösung0,001 ppm minimum, auto ranging, up to 4 significant digitsTDS - Genauigkeit0,5% of reading ±1 digitTDS - UmrechnungsfaktorLinear (0,02 - 9,99)DO Konzentration0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)Sauerstoff - Auflösung0,1 / 0,01 mg/LSauerstoff - Sättigung0 - 600 % (polarographic); 0 - 500 % (RDO)DO GenauigkeitPolarographic: ±0,2 mg/l or ±2% of reading, whichever is greater
RDO: ±0,1 mg/l (up to 8 mg/), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)DO KalibrierungWater-saturated air, air saturated water, manual (Winkler) and zero pointSauerstoff – LuftdruckbereichAutomatic or manual, 450 - 850 mmHgTemperaturbereich–5,0...+105,0 °C (–5,0...+50,0 °C with DO)Temperaturauflösung0,1 °CTemperaturgenauigkeit±0,1 °CTemperatur-Kalibrierung1 point temperature offset calibrationTemperatur - KompensationAutomatic or manualDruckbereiche400 - 850 mm HgPressure resolution1 mm HgDisplayGraphic LCD with backlightAkku-Typ4 AA (included)Batterielebensdauer800 hoursStromversorgungAC adapter or 4 AA batteriesKonformitätIP 67Datenprotokollierung - LogfunktionManual / Automatic with AUTO-READ™Kapazität Datenprotokollierung5000SpeicherNon-volatile memory preserves data log, calibration log and meter settingsSprachenEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software updateSchutzklasseIP 67AnschlüsseBNC, pin tip, 8- and 9-pin mini-DINAusgängeRS232, USBEingang3 measuring channelsAlarmHigh/low limit alarm, calibration due alarmAnzahl der Kanäle3KalibrierungpH with calibration editing option, ion concentration (ISE) with calibration editing option, relativKalibrierpunkte1 point relative mV (RmV) mode, 1 point ORP modeB×T×H60×105×240 mmGewicht0,5 kg
Accessories
Produktinformationen
- Artikelnr.BezeichnungFürVerfügbarkeitPreis
- 662-1140Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cableThermo Scientific™ Orion™ Versa Star meters, Orion™ Star A series meters (Star A320, Star A220 and Star A210 series) and legacy Orion™ Star and Star Plus metersEinloggen für Verfügbarkeit1 * 1 SET - 76,40 €
Produktinformationen
- Artikelnr.BezeichnungVerfügbarkeitPreis
- ORIOSTARA-ESPHOrion™ Star™ A Series portable meter pH electrode holder, can be attached to the portable meter armor and holds one pH electrode when placed in the pH electrode storage sleeveEinloggen für Verfügbarkeit1 * 1 ST - 29,50 €
Produktinformationen
- Artikelnr.BezeichnungVerfügbarkeitPreis
- ORIOSTARA-CSHard-sided field case for portable meters, holds meter (with or without armor), portable electrode holders, extra batteries, solutions, pH electrode in storage sleeve, conductivity probe and dissolved oxygen probe in storage sleeveEinloggen für Verfügbarkeit1 * 1 ST - 144,00 €
Produktinformationen
- Artikelnr.BezeichnungVerfügbarkeitPreis
- 662-1547Spare universal power adapter for Thermo Scientific™ Orion™ Star A series benchtop and portable meters and legacy Orion™ Star and Star Plus series metersEinloggen für Verfügbarkeit1 * 1 ST - 72,40 €
Produktinformationen
- Artikelnr.BezeichnungVerfügbarkeitPreis
- ORIOSTARA-ESCDOrion™ Star A Series portable meter conductivity and DO probe holder, can be attached to either side of the portable meter armor and holds 12/15 mm Ø conductivity probes and a dissolved oxygen probe when placed in its calibration sleeveEinloggen für Verfügbarkeit1 * 1 ST - 29,50 €
Produktinformationen
- Artikelnr.BezeichnungVerfügbarkeitPreis
- ORIOSTARA-ARProtective armor for portable meters, incl. hand strap and built-in stand, pH electrode storage sleeve, pH electrode holder, conductivity and dissolved oxygen sensor holderEinloggen für Verfügbarkeit1 * 1 ST - 102,00 €
Produktinformationen
- Artikelnr.BezeichnungVerfügbarkeitPreis
- ORIO1210005Soft-sided field case, incl. interior dividers and exterior pockets to safely organise the meter and accessories in the fieldEinloggen für Verfügbarkeit1 * 1 ST - 161,00 €
Produktinformationen
- Artikelnr.BezeichnungFürVerfügbarkeitPreis
- ORIO1010053RS232 cable, for connecting a meter to a PC or printerOrion™ Versa Star, Orion™ Star A series (A320, A220 + A210 series), Orion™ Dual Star benchtop meters, Orion 3-Star, 4-Star and 5-Star metersEinloggen für Verfügbarkeit1 * 1 ST - 45,40 €
Produktinformationen
- Artikelnr.BezeichnungFürVerfügbarkeitPreis
- ORIO1010005Cable adapter, for connecting the RS232 port of a meter to a USB portOrion™ Versa Star, Orion™ Star A series (A320, A220 + A210 series) and Orion™ Star and Star Plus metersEinloggen für Verfügbarkeit1 * 1 ST - 131,00 €